Literature DB >> 15611941

Contrast-enhanced peripheral MR angiography using SENSE in multiple stations: feasibility study.

Marianne de Vries1, Robbert J Nijenhuis, Romhild M Hoogeveen, Michiel W de Haan, Jos M A van Engelshoven, Tim Leiner.   

Abstract

PURPOSE: To investigate if the use of parallel imaging is feasible and beneficial for peripheral contrast-enhanced magnetic resonance angiography (CE-MRA).
MATERIALS AND METHODS: A total of 19 consecutive patients underwent peripheral CE-MRA using SENSE with two-fold reduction in the upper and lower leg stations. Conventional nonaccelerated imaging using constant level appearance (CLEAR) was used in the aortoiliac station. The findings were compared with those in a similar patient group that underwent peripheral CE-MR angiography using our standard imaging protocol without SENSE. Intraarterial digital subtraction angiography (IA-DSA) was used as the standard of reference. Lower extremity vessels were divided into anatomic segments (aortoiliac, upper legs, lower legs) for review. In each anatomic segment signal- and contrast-to-noise ratios (SNR, CNR), venous contamination, subjective image quality, as well as sensitivity and specificity, were determined for both patient groups.
RESULTS: SNR and CNR improved significantly for the aortoiliac and upper leg segments (all P-values < or = 0.001). Small reductions were seen in the frequency of disturbing venous enhancement (P = not significant). There were no significant differences with regards to subjective image quality or diagnostic accuracy (all P > 0.3). Overall sensitivity and specificity in the SENSE group were 81% and 95%, respectively. For the non-SENSE group, these values were 79% and 96%, respectively.
CONCLUSION: Preliminary results show that three-station peripheral CE-MRA using a full length peripheral arterial coil in combination with SENSE in the upper and lower leg stations is feasible and useful for further optimization of peripheral MRA. Using SENSE allows for routine, high-quality depiction of the entire peripheral vascular tree including the pedal arch. Higher SENSE factors are needed for further optimization.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15611941     DOI: 10.1002/jmri.20240

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  14 in total

1.  Comprehensive MR angiography of the lower limbs: a hybrid dual-bolus approach including the pedal arteries.

Authors:  R Schmitt; G Coblenz; O Cherevatyy; H Brunner; S Fröhner; E Wedell; G Karg; G Christopoulos
Journal:  Eur Radiol       Date:  2005-07-22       Impact factor: 5.315

2.  Intrinsic signal amplification in the application of 2D SENSE parallel imaging to 3D contrast-enhanced elliptical centric MRA and MRV.

Authors:  Stephen J Riederer; Houchun Harry Hu; David G Kruger; Clifton R Haider; Norbert G Campeau; John Huston
Journal:  Magn Reson Med       Date:  2007-11       Impact factor: 4.668

3.  Recent advances in 3D time-resolved contrast-enhanced MR angiography.

Authors:  Stephen J Riederer; Clifton R Haider; Eric A Borisch; Paul T Weavers; Phillip M Young
Journal:  J Magn Reson Imaging       Date:  2015-06-01       Impact factor: 4.813

Review 4.  Diagnostic performance of computed tomography angiography and contrast-enhanced magnetic resonance angiography in patients with critical limb ischaemia and intermittent claudication: systematic review and meta-analysis.

Authors:  Sjoerd Jens; Mark J W Koelemay; Jim A Reekers; Shandra Bipat
Journal:  Eur Radiol       Date:  2013-06-26       Impact factor: 5.315

5.  Three-station three-dimensional bolus-chase MR angiography with real-time fluoroscopic tracking.

Authors:  Casey P Johnson; Paul T Weavers; Eric A Borisch; Roger C Grimm; Thomas C Hulshizer; Christine C LaPlante; Phillip J Rossman; James F Glockner; Phillip M Young; Stephen J Riederer
Journal:  Radiology       Date:  2014-03-14       Impact factor: 11.105

6.  Time-resolved bolus-chase MR angiography with real-time triggering of table motion.

Authors:  Casey P Johnson; Clifton R Haider; Eric A Borisch; James F Glockner; Stephen J Riederer
Journal:  Magn Reson Med       Date:  2010-09       Impact factor: 4.668

Review 7.  Recent advances in parallel imaging for MRI.

Authors:  Jesse Hamilton; Dominique Franson; Nicole Seiberlich
Journal:  Prog Nucl Magn Reson Spectrosc       Date:  2017-05-02       Impact factor: 9.795

8.  Total-body 3D magnetic resonance angiography influences the management of patients with peripheral arterial occlusive disease.

Authors:  Mathias Goyen; Christoph U Herborn; Knut Kröger; Stefan G Ruehm; Jörg F Debatin
Journal:  Eur Radiol       Date:  2005-09-21       Impact factor: 5.315

9.  Time-resolved MR angiography of the legs at 3 T using a low dose of gadolinium: initial experience and contrast dynamics.

Authors:  Gurpreet Singh Sandhu; Rod P Rezaee; John Jesberger; Katherine Wright; Mark A Griswold; Vikas Gulani
Journal:  AJR Am J Roentgenol       Date:  2012-03       Impact factor: 3.959

10.  [Critical limb ischemia].

Authors:  C Denzel; W Lang
Journal:  Chirurg       Date:  2008-05       Impact factor: 0.955

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.