BACKGROUND:Female patients undergoingarthroscopic anterior cruciate ligament reconstruction with a hamstring tendon graft developed increased postoperative laxity compared to male and female patients who had reconstruction using a patellar tendon graft. This difference may be due to graft slippage in less dense female tibial bone. HYPOTHESIS: Reinforcement of tibial fixation of the hamstring tendon graft in women by supplementary methods may reduce laxity. STUDY DESIGN: Randomized controlled clinical trial; Level of evidence, 2. METHODS:Fifty-six female patients divided into 2 groups (standard tibial fixation with 7 x 25-mm metal interference screw versus metal interference screw with supplementary staple fixation) were followed for 2 years. RESULTS: After 2 years, the mean side-to-side difference using KT-1000 arthrometer manual maximum measurements was 1.8 mm (standard group) and 1.1 mm (staple group) (P=.05). The percentage of patients with a side-to-side difference of <3 mm did not differ significantly between the 2 groups (P=.66): 88.8% of the standard group versus 90.5% of the staple group. A grade 0 Lachman test result was present in 63% of the standard group and 86% of the staple group (P=.04). Kneeling pain was experienced by 7% of the standard group and 29% of the staple group (P=.05). CONCLUSIONS:Supplementary tibial fixation in female patients undergoing anterior cruciate ligament reconstruction withhamstring tendon graft in addition to a single-size screw significantly improves laxity measurements and clinical stability assessment 2 years after surgery. However, this improvement is at the cost of increased kneeling pain.
RCT Entities:
BACKGROUND: Female patients undergoing arthroscopic anterior cruciate ligament reconstruction with a hamstring tendon graft developed increased postoperative laxity compared to male and female patients who had reconstruction using a patellar tendon graft. This difference may be due to graft slippage in less dense female tibial bone. HYPOTHESIS: Reinforcement of tibial fixation of the hamstring tendon graft in women by supplementary methods may reduce laxity. STUDY DESIGN: Randomized controlled clinical trial; Level of evidence, 2. METHODS: Fifty-six female patients divided into 2 groups (standard tibial fixation with 7 x 25-mm metal interference screw versus metal interference screw with supplementary staple fixation) were followed for 2 years. RESULTS: After 2 years, the mean side-to-side difference using KT-1000 arthrometer manual maximum measurements was 1.8 mm (standard group) and 1.1 mm (staple group) (P=.05). The percentage of patients with a side-to-side difference of <3 mm did not differ significantly between the 2 groups (P=.66): 88.8% of the standard group versus 90.5% of the staple group. A grade 0 Lachman test result was present in 63% of the standard group and 86% of the staple group (P=.04). Kneeling pain was experienced by 7% of the standard group and 29% of the staple group (P=.05). CONCLUSIONS: Supplementary tibial fixation in female patients undergoing anterior cruciate ligament reconstruction with hamstring tendon graft in addition to a single-size screw significantly improves laxity measurements and clinical stability assessment 2 years after surgery. However, this improvement is at the cost of increased kneeling pain.
Authors: María Prado; Belén Martín-Castilla; Alejandro Espejo-Reina; José Miguel Serrano-Fernández; Ana Pérez-Blanca; Francisco Ezquerro Journal: Knee Surg Sports Traumatol Arthrosc Date: 2012-03-30 Impact factor: 4.342
Authors: Antonio Pasquale Vadalà; Raffaele Iorio; Angelo De Carli; Alberto Bonifazi; Carlo Iorio; Andrea Gatti; Cristina Rossi; Andrea Ferretti Journal: Int Orthop Date: 2012-05-24 Impact factor: 3.075