Validation of a sensitivity performance index test protocol and evaluation of colour Doppler sensitivity for a range of ultrasound scanners.

Jacinta E Browne1, Amanda J Watson, Peter R Hoskins, Alex T Elliott.   

Abstract

The ability to detect flow is the most crucial aspect of an ultrasound (US) system because, if flow cannot be detected, no other aspect of performance matters. The objectives of this study were to validate a Doppler "sensitivity performance index," a figure of merit, and to determine if it could be used to differentiate colour Doppler sensitivity performance in scanners of varying complexity. The sensitivity performance index was developed to give a combined measure of related aspects of sensitivity, such as the lowest detectable velocity, the vessel size and the penetration depth. The colour Doppler sensitivity was evaluated objectively as the lowest detectable velocity signal from the deepest achievable point within the Doppler sensitivity phantom free from extraneous noise in a small diameter vessel (3.2 mm inner diameter). The effect of vessel size and mean velocity on the sensitivity performance index were investigated and it was found that the index was not proportional to vessel size, but this may be accounted for by considering the effect of the acoustic properties of the vessel material, the clutter filter and beam shape. The results obtained using flow phantoms with vessel sizes different from those used in this study are, therefore, not directly comparable to the results found in this study; however, a similar trend should be found in the results for the effect of control settings and a similar range of US scanners. It was found that the Doppler sensitivity performance index was a robust challenging test because none of the US scanners evaluated was capable of achieving the highest sensitivity performance index score, which would be limited by the lowest pump velocity and the deepest point of the vessel within the flow phantom. Therefore, this suggests that this method of determining Doppler sensitivity performance is valuable in the absence of other suitable methods, despite the fact that the relationship between the sensitivity performance index and vessel size is not proportional. Furthermore, use of the Doppler sensitivity performance index for the evaluation of a range of scanners demonstrated that curvilinear transducers have higher sensitivity performance indices than higher-frequency linear transducers, due to the higher achievable penetration depth. The effect of instrument settings was assessed for two transducers, the 4C3 curvilinear general-purpose transducer (Aspen) and the PVM375AT curvilinear general-purpose transducer (Nemio). The colour Doppler sensitivity performance was found to be significantly dependent on the clutter filter setting and the output power setting for both transducers tested. Users need to be aware of the effect of these settings on the colour Doppler sensitivity performance of their US scanner when interpreting the clinical significance of the colour Doppler information.

Mesh:

Year:  2004        PMID: 15588958     DOI: 10.1016/j.ultrasmedbio.2004.09.005

Source DB:  PubMed          Journal:  Ultrasound Med Biol        ISSN: 0301-5629            Impact factor:   2.998


  12 in total

Review 1.  A comparison of the diagnostic performance of systematic versus ultrasound-guided biopsies of prostate cancer.

Authors:  Stijn W T P J Heijmink; Hilco van Moerkerk; Lambertus A L M Kiemeney; J Alfred Witjes; Ferdinand Frauscher; Jelle O Barentsz
Journal:  Eur Radiol       Date:  2006-01-04       Impact factor: 5.315

2.  LED-Based Photoacoustic Imaging for Monitoring Angiogenesis in Fibrin Scaffolds.

Authors:  Yunhao Zhu; Xiaofang Lu; Xiaoxiao Dong; Jie Yuan; Mario L Fabiilli; Xueding Wang
Journal:  Tissue Eng Part C Methods       Date:  2019-09-11       Impact factor: 3.056

3.  Quantitation of hypoechoic lesions for the prediction and Gleason grading of prostate cancer: a prospective study.

Authors:  Kwang Suk Lee; Kyo Chul Koo; Byung Ha Chung
Journal:  World J Urol       Date:  2018-03-05       Impact factor: 4.226

4.  Power Doppler ultrasonography and synovitis: correlating ultrasound imaging with histopathological findings and evaluating the performance of ultrasound equipments.

Authors:  J M Koski; S Saarakkala; M Helle; U Hakulinen; J O Heikkinen; H Hermunen
Journal:  Ann Rheum Dis       Date:  2006-05-17       Impact factor: 19.103

5.  Quantitative assessment of synovial vascularity using contrast-enhanced power Doppler ultrasonography: correlation with histologic findings and mr imaging findings in arthritic rabbit knee model.

Authors:  Sang Hoon Lee; Jin Suck Suh; Myung Jin Shin; Seong Moon Kim; Namkug Kim; Sang Hyun Suh
Journal:  Korean J Radiol       Date:  2008 Jan-Feb       Impact factor: 3.500

6.  Calibrating Doppler imaging of preterm intracerebral circulation using a microvessel flow phantom.

Authors:  Fleur A Camfferman; Ginette M Ecury-Goossen; Jhuresy E La Roche; Nico de Jong; Willem van 't Leven; Hendrik J Vos; Martin D Verweij; Kazem Nasserinejad; Filip Cools; Paul Govaert; Jeroen Dudink
Journal:  Front Hum Neurosci       Date:  2015-01-13       Impact factor: 3.169

Review 7.  A Review of Suspension-Scattered Particles Used in Blood-Mimicking Fluid for Doppler Ultrasound Imaging.

Authors:  Ammar A Oglat; Nursakinah Suardi; M Z Matjafri; Mohammad A Oqlat; Mostafa A Abdelrahman; Ahmad A Oqlat
Journal:  J Med Ultrasound       Date:  2018-05-07

8.  Very different performance of the power Doppler modalities of several ultrasound machines ascertained by a microvessel flow phantom.

Authors:  David F Ten Cate; Jolanda J Luime; Myrthe van der Ven; Johanna M W Hazes; Klazina Kooiman; Nico de Jong; Johannes G Bosch
Journal:  Arthritis Res Ther       Date:  2013-10-24       Impact factor: 5.156

Review 9.  Chemical Items Used for Preparing Tissue-Mimicking Material of Wall-Less Flow Phantom for Doppler Ultrasound Imaging.

Authors:  Ammar A Oglat; M Z Matjafri; Nursakinah Suardi; Mohammad A Oqlat; Mostafa A Abdelrahman; Ahmad A Oqlat; Omar F Farhat; Batool N Alkhateb; Raed Abdalrheem; Muntaser S Ahmad; Mohammed Y M Abujazar
Journal:  J Med Ultrasound       Date:  2018-05-07

10.  A New Scatter Particle and Mixture Fluid for Preparing Blood Mimicking Fluid for Wall-Less Flow Phantom.

Authors:  Ammar A Oglat; M Z Matjafri; Nursakinah Suardi; Mostafa A Abdelrahman; Mohammad A Oqlat; Ahmad A Oqlat
Journal:  J Med Ultrasound       Date:  2018-09-14
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.