X-ray spectroscopy in mammography with a silicon PIN photodiode with application to the measurement of tube voltage.

Roseli Künzel1, Silvio Bruni Herdade, Ricardo Andrade Terini, Paulo Roberto Costa.   

Abstract

In this work a silicon PIN photodiode was employed in mammographic x-ray spectroscopy under clinical and nonclinical conditions. Measurements have been performed at a constant potential tungsten anode tube, adapted in this work with molybdenum filters to produce a beam like that used in mammography, and at a clinical equipment with a molybdenum anode tube by using an additional aluminum filtration. The corrected x-ray spectra were in full agreement with those generated by theoretical models published in the literature and agree well with those measured with a CdZnTe detector for tube voltages less than 30 kV. The half value layer and the relative exposure values calculated from the corrected silicon PIN photodiode spectra were in agreement with those measured with an ionization chamber. These results indicate that a silicon PIN photodiode are very suitable for mammographic x-ray spectroscopy. As an application, the voltage (kV) applied to mammographic x-ray equipment has been measured through the evaluation of the spectra high energy cut off. Uncertainties evaluated for the voltage values calculated from the measured spectra are less than 0.13% for voltages in the range 20-35 kV. The low uncertainties associated with the obtained results in this work point out that the method employed can be accurately used for calibration of noninvasive mammographic kVp meters.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15587652     DOI: 10.1118/1.1803432

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  3 in total

1.  Experimental and Monte Carlo-simulated spectra of standard mammography-quality beams.

Authors:  M G David; E J Pires; M A Bernal; J G Peixoto; C E Dealmeida
Journal:  Br J Radiol       Date:  2011-10-18       Impact factor: 3.039

2.  Possible use of CdTe detectors in kVp monitoring of diagnostic x-ray tubes.

Authors:  M Krmar; N Bucalović; M Baucal; N Jovančević
Journal:  Nucl Instrum Methods Phys Res A       Date:  2010-10-01       Impact factor: 1.455

3.  Direct measurement of mammographic X-ray spectra with a digital CdTe detection system.

Authors:  Leonardo Abbene; Gaetano Gerardi; Fabio Principato; Stefano Del Sordo; Giuseppe Raso
Journal:  Sensors (Basel)       Date:  2012-06-18       Impact factor: 3.576

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.