Literature DB >> 15587469

New hybrid stochastic-deterministic technique for fast registration of dermatological images.

S A Pavlopoulos1.   

Abstract

Digital image processing in the medical field has become very popular in recent years owing to the significant advantages it offers over conventional techniques of visual or analogue image analysis. One of the most significant aspects in medical image processing has been that of image registration, which deals with the task of registering two images taken under different conditions. Image registration is considered an important issue in the field of dermatology, as pictures of a lesion taken in different periods need to be compared and quantitatively analysed. A hybrid image registration scheme was developed and evaluated for dermatological applications. The method splits the parameter estimation problem into two, with a combination of deterministic and iterative estimation techniques. The scaling and rotation parameters are estimated using a cross-correlation of image invariant image descriptors algorithm, whereas the two translation parameters are estimated with a non-parametric similarity criterion and a hill-climbing optimisation scheme. The efficacy of the method has been validated for the registration and comparison of malignant melanoma images. Determination of rotation and scaling parameters was performed using the log-polar transformation technique, which proved to be very accurate, even when high rotation and scaling values were imposed. Deviations for the rotation parameter estimations were less than 0.5%, whereas, for the scaling factor, differences were on average less than 2.5%, with a maximum difference estimated to be 4.5%. Translation parameter estimation was performed using integer similarity measures namely the stochastic sign change, the deterministic sign change (DSC) and the window value range, the performance of which has been assessed and, in all cases, was found to be highly effective. A novel hill-climbing optimisation algorithm has been proposed and, in combination with the DSC similarity criterion, was evaluated and proved to successfully estimate translation parameters. Thus the proposed hybrid registration technique can successfully estimate problem parameters in a time-efficient manner.

Entities:  

Mesh:

Year:  2004        PMID: 15587469     DOI: 10.1007/bf02345211

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  13 in total

Review 1.  A survey of medical image registration.

Authors:  J B Maintz; M A Viergever
Journal:  Med Image Anal       Date:  1998-03       Impact factor: 8.545

2.  Towards a computer-aided diagnosis system for pigmented skin lesions.

Authors:  Philippe Schmid-Saugeona; Joël Guillodb; Jean-Philippe Thirana
Journal:  Comput Med Imaging Graph       Date:  2003       Impact factor: 4.790

3.  High-speed registration of three- and four-dimensional medical images by using voxel similarity.

Authors:  Raj Shekhar; Vladimir Zagrodsky; Carlos R Castro-Pareja; Vivek Walimbe; Jogikal M Jagadeesh
Journal:  Radiographics       Date:  2003 Nov-Dec       Impact factor: 5.333

4.  Automatic registration of multiple skin lesions by use of point pattern matching.

Authors:  D A Perednia; R G White
Journal:  Comput Med Imaging Graph       Date:  1992 May-Jun       Impact factor: 4.790

5.  Automatic derivation of initial match points for paired digital images of skin.

Authors:  R G White; D A Perednia
Journal:  Comput Med Imaging Graph       Date:  1992 May-Jun       Impact factor: 4.790

6.  Coincident bit counting-a new criterion for image registration.

Authors:  J Y Chiang; B J Sullivan
Journal:  IEEE Trans Med Imaging       Date:  1993       Impact factor: 10.048

7.  An automated system for the registration and comparison of photographic images in medicine.

Authors:  A Venot; J Y Devaux; M Herbin; J F Lebruchec; L Dubertret; Y Raulo; J C Roucayrol
Journal:  IEEE Trans Med Imaging       Date:  1988       Impact factor: 10.048

8.  A comparison of similarity measures for use in 2-D-3-D medical image registration.

Authors:  G P Penney; J Weese; J A Little; P Desmedt; D L Hill; D J Hawkes
Journal:  IEEE Trans Med Imaging       Date:  1998-08       Impact factor: 10.048

9.  Automated melanoma recognition.

Authors:  H Ganster; A Pinz; R Röhrer; E Wildling; M Binder; H Kittler
Journal:  IEEE Trans Med Imaging       Date:  2001-03       Impact factor: 10.048

Review 10.  Cancer statistics, 2004.

Authors:  Ahmedin Jemal; Ram C Tiwari; Taylor Murray; Asma Ghafoor; Alicia Samuels; Elizabeth Ward; Eric J Feuer; Michael J Thun
Journal:  CA Cancer J Clin       Date:  2004 Jan-Feb       Impact factor: 508.702

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.