Literature DB >> 14615572

High-speed registration of three- and four-dimensional medical images by using voxel similarity.

Raj Shekhar1, Vladimir Zagrodsky, Carlos R Castro-Pareja, Vivek Walimbe, Jogikal M Jagadeesh.   

Abstract

A generalized, accurate, automatic, retrospective method of image registration for three-dimensional images has been developed. The method is based on mutual information, a specific measure of voxel similarity, and is applicable to a wide range of imaging modalities and organs, rigid or deformable. A drawback of mutual information-based image registration is long execution times. To overcome the speed problem, low-cost, customized hardware to accelerate this computationally intensive task was developed. Individual hardware accelerator units (each, in principle, 25-fold faster than a comparable software implementation) can be concatenated to perform image registration at any user-desired speed. A first-generation prototype board with two processing units provided a 12- to 16-fold increase in speed. Enhancements for increasing the speed further are being developed. These advances have enabled many nontraditional applications of image registration and have made the traditional applications more efficient. Clinical applications include fusion of computed tomographic (CT), magnetic resonance, and positron emission tomographic (PET) images of the brain; fusion of whole-body CT and PET images; fusion of four-dimensional spatiotemporal ultrasonographic (US) and single photon emission CT images of the heart; and correction of misalignment between pre- and poststress four-dimensional US images. Copyright RSNA, 2003

Entities:  

Mesh:

Year:  2003        PMID: 14615572     DOI: 10.1148/rg.236035041

Source DB:  PubMed          Journal:  Radiographics        ISSN: 0271-5333            Impact factor:   5.333


  4 in total

1.  New hybrid stochastic-deterministic technique for fast registration of dermatological images.

Authors:  S A Pavlopoulos
Journal:  Med Biol Eng Comput       Date:  2004-11       Impact factor: 2.602

2.  Alignment of 3-dimensional cardiac structures in O-15-labeled water PET emission images with mutual information.

Authors:  Anu Juslin; Jyrki Lötjönen; Sergey V Nesterov; Kari Kalliokoski; Juhani Knuuti; Ulla Ruotsalainen
Journal:  J Nucl Cardiol       Date:  2007-01       Impact factor: 5.952

3.  Real-time image-based rigid registration of three-dimensional ultrasound.

Authors:  Robert J Schneider; Douglas P Perrin; Nikolay V Vasilyev; Gerald R Marx; Pedro J Del Nido; Robert D Howe
Journal:  Med Image Anal       Date:  2011-11-15       Impact factor: 8.545

4.  Quantifying the accuracy of automated structure segmentation in 4D CT images using a deformable image registration algorithm.

Authors:  Krishni Wijesooriya; E Weiss; V Dill; L Dong; R Mohan; S Joshi; P J Keall
Journal:  Med Phys       Date:  2008-04       Impact factor: 4.071

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.