Literature DB >> 15587037

The need to protect the thyroid gland during image intensifier use in orthopaedic procedures.

Kailash Laxman Devalia1, Abhijit Guha, Vijay G Devadoss.   

Abstract

The image intensifier has become an essential part of the orthopaedic surgeon's armamentarium. Its increasing use, however, may expose medical staff and theatre personnel to high doses of radiation. The aim of this study was to assess the compliance of surgeons and staff with radiation protection protocols, especially the use of the thyroid shield and to calculate the radiation exposure dose during routine orthopaedic procedures. We carried out this prospective study of 44 consecutive cases at the Rochdale Infirmary. The total dose of radiation and the total number of images taken were found to be more during hip surgery such as dynamic hip screw fixation for intertrochanteric fracture (1,715.5 mGy.cm2) and the intramedullary nailing (4,357.5 mGy.cm2). However the total percentage of the theatre personnel wearing thyroid shield was as low as 4% (14 people out of total 345 people present in theatre in 44 procedures) in spite of its availability. The consistent neglect in the use of the thyroid shield by surgeons and nursing staff present in theatre during fluoroscopically assisted procedures is a matter for concern. The data presented in this study will emphasise the need to wear a thyroid collar during orthopaedic procedures and the need for better guidelines to protect theatre personnel as well as patients from radiation exposure hazards.

Entities:  

Mesh:

Year:  2004        PMID: 15587037

Source DB:  PubMed          Journal:  Acta Orthop Belg        ISSN: 0001-6462            Impact factor:   0.500


  6 in total

1.  Radiation exposure to the orthopaedic surgeon during periacetabular osteotomy.

Authors:  Inger Mechlenburg; Henrik Daugaard; Kjeld Søballe
Journal:  Int Orthop       Date:  2008-10-29       Impact factor: 3.075

2.  [X-ray in trauma and orthopedic surgery. Physical and biological impact, reasonable use, and radiation protection in the operating room].

Authors:  K Dresing
Journal:  Oper Orthop Traumatol       Date:  2011-02       Impact factor: 1.154

Review 3.  Radiation protection and standardization.

Authors:  O P Lakhwani; Vipin Dalal; Mohit Jindal; Ashok Nagala
Journal:  J Clin Orthop Trauma       Date:  2018-08-07

4.  Elevated Radiation Exposure Associated With Above Surface Flat Detector Mini C-Arm Use.

Authors:  Dennis P Martin; Talia Chapman; Christopher Williamson; Brian Tinsley; Asif M Ilyas; Mark L Wang
Journal:  Hand (N Y)       Date:  2017-11-22

5.  Are Indian orthopaedic surgeons aware of the health hazards of radiation exposure? A survey and review on awareness and ways to mitigate them.

Authors:  Binoti Sheth; Arzan Jesia; Rohan Parihar; Rohit Somani; Pankaj Pawar
Journal:  J Clin Orthop Trauma       Date:  2022-08-07

Review 6.  Intraoperative radiation safety in orthopaedics: a review of the ALARA (As low as reasonably achievable) principle.

Authors:  Daniel J Kaplan; Jay N Patel; Frank A Liporace; Richard S Yoon
Journal:  Patient Saf Surg       Date:  2016-12-12
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.