Literature DB >> 15586334

The effect of tibial polyethylene insert design on range of motion: evaluation of in vivo knee kinematics by a computerized navigation system during total knee arthroplasty.

Gregg R Klein1, Javad Parvizi, Venkat R Rapuri, Mathew S Austin, William J Hozack.   

Abstract

Computer-assisted navigation for total knee arthroplasty offers the unique opportunity to assess in vivo knee kinematics during surgery and implement changes whenever appropriate. Using a computerized navigation system, the effect of 2 tibial polyethylene insert designs on knee kinematics in general and knee range of motion (ROM) in particular was evaluated in 37 knee arthroplasties in 30 patients. The Scorpioflex tibial insert was found to provide a significant increase in mean extension, mean flexion, and overall ROM of the knee compared with the standard tibial insert (P<.005) without affecting knee ligamentous balance. Navigation is a very effective and useful tool for intraoperative assessment of knee kinematics and accurate recording of ROM. Based on the information obtained from the navigation software, the surgeon can implement changes in selection of the knee components with beneficial effects in knee kinematics in general and knee ROM in particular. This may, in turn, translate to better clinical outcome of the knee arthroplasty.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15586334

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  8 in total

1.  Navigation-based femorotibial rotation pattern correlated with flexion angle after total knee arthroplasty.

Authors:  Kazunari Ishida; Nao Shibanuma; Tomoyuki Matsumoto; Hiroshi Sasaki; Koji Takayama; Tokio Matsuzaki; Katsumasa Tei; Ryosuke Kuroda; Masahiro Kurosaka
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2014-09-27       Impact factor: 4.342

2.  Comparison of stability and kinematics of the natural knee versus a PS TKA with a 'third condyle'.

Authors:  Stefano Zaffagnini; Simone Bignozzi; Mo Saffarini; Francesca Colle; Bharat Sharma; Plamen Slavov Kinov; Maurilio Marcacci; David Dejour
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2014-05-06       Impact factor: 4.342

3.  Alignment of the lower extremity mechanical axis by computer-aided design and application in total knee arthroplasty.

Authors:  Yuan Z Zhang; Sheng Lu; Hui Q Zhang; Zhong M Jin; Jian M Zhao; Jian Huang; Zhi F Zhang
Journal:  Int J Comput Assist Radiol Surg       Date:  2016-03-26       Impact factor: 2.924

4.  Factors affecting intraoperative kinematic patterns and flexion angles in navigated total knee arthroplasty.

Authors:  Kazunari Ishida; Nao Shibanuma; Tomoyuki Matsumoto; Hiroshi Sasaki; Koji Takayama; Akihiko Toda; Ryosuke Kuroda; Masahiro Kurosaka
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2015-03-13       Impact factor: 4.342

5.  Range of motion and function are similar in patients undergoing TKA with posterior stabilised and high-flexion inserts.

Authors:  Aamer Malik; Antonio Salas; Judith Ben Ari; Yan Ma; Alejandro González Della Valle
Journal:  Int Orthop       Date:  2009-10-20       Impact factor: 3.075

6.  Kinematic factors affecting postoperative knee flexion after cruciate-retaining total knee arthroplasty.

Authors:  Tokio Matsuzaki; Tomoyuki Matsumoto; Hirotsugu Muratsu; Seiji Kubo; Takehiko Matsushita; Yohei Kawakami; Kazunari Ishida; Shinya Oka; Ryosuke Kuroda; Masahiro Kurosaka
Journal:  Int Orthop       Date:  2013-03-05       Impact factor: 3.075

7.  [Clinical application of distal femoral patient-specific cutting guide based on knee CT and full-length X-ray film of lower extremities].

Authors:  Bi Wu; Yue Wang; Peng Hao; Junwei Feng
Journal:  Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi       Date:  2021-02-15

8.  Outcomes of the different types of total knee arthroplasty with the identical femoral geometry.

Authors:  Sang Min Lee; Sang Cheol Seong; Sahnghoon Lee; Won Chul Choi; Myung Chul Lee
Journal:  Knee Surg Relat Res       Date:  2012-11-29
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.