Literature DB >> 15586331

Effect of augmented cup fixation on stability, wear, and osteolysis: a 5-year follow-up of total hip arthroplasty with RSA.

Stephan M Röhrl1, Bosse Nivbrant, Håkan Ström, Kjell G Nilsson.   

Abstract

To evaluate different modes of cementless fixation of hemispherical cups, we operated on 87 hips in 81 patients using 4 different means of cup fixation. The hips were randomly assigned to fixation with press-fit technique only (PF), or with augmentation with screws (S), pegs (P), or hydroxyapatite (HA) coating. The patients were evaluated with radiostereometric analysis (RSA) for cup migration and wear, conventional radiography for osteolysis, and Harris Hip Score for clinical outcome over 5 years. The fixation of the cups did not differ between the groups, but HA showed a tendency to decrease proximal migration. HA-coated cups displayed the best interface with hardly any signs of radiolucent lines, indicating a superior sealing effect of the HA coating. Cups with screws or pegs had more radiolucent lines and osteolytic lesions than the other groups. Radiolucent lines were correlated to higher proximal migration, young age, and female gender (r2=.2). The wear rate of the ethylene oxide-sterilized polyethylene liner was high (0.2 mm/y) but did not differ between the groups. Two cups with a perioperative fracture of the acetabular rim showed large initial migration but stabilized thereafter.

Entities:  

Mesh:

Year:  2004        PMID: 15586331     DOI: 10.1016/j.arth.2004.06.024

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  27 in total

1.  The effects of different weight-bearing regimes on press-fit cup stability: a randomised study with five years of follow-up using radiostereometry.

Authors:  Olof Wolf; Per Mattsson; Jan Milbrink; Sune Larsson; Hans Mallmin
Journal:  Int Orthop       Date:  2011-12-07       Impact factor: 3.075

2.  Metropolitan and micropolitan statistical area estimates of depression and anxiety using the Patient Health Questionnaire-8 in the 2006 Behavioral Risk Factor Surveillance System.

Authors:  Tara W Strine; Satvinder S Dhingra; Kurt Kroenke; Mohamed Qayad; James L Ribble; Catherine A Okoro; Lina S Balluz; Shanta R Dube; James Lando; Ali H Mokdad
Journal:  Int J Public Health       Date:  2009       Impact factor: 3.380

Review 3.  Do monoblock cups improve survivorship, decrease wear, or reduce osteolysis in uncemented total hip arthroplasty?

Authors:  Jelle J Halma; H Charles Vogely; Wouter J Dhert; Steven M Van Gaalen; Arthur de Gast
Journal:  Clin Orthop Relat Res       Date:  2013-08-03       Impact factor: 4.176

4.  Press-fit cementless acetabular fixation with and without screws.

Authors:  Sheng-Hui Ni; Lei Guo; Tian-Long Jiang; Jie Zhao; Yan-Gang Zhao
Journal:  Int Orthop       Date:  2013-08-28       Impact factor: 3.075

5.  [Reconstruction of large acetabular defects using trabecular metal augments].

Authors:  Olaf Hasart; Carsten Perka; Rex Lehnigk; Stephan Tohtz
Journal:  Oper Orthop Traumatol       Date:  2010-07       Impact factor: 1.154

6.  Bone remodelling around HA-coated acetabular cups : a DEXA study with a 3-year follow-up in a randomised trial.

Authors:  M B Laursen; P T Nielsen; K Søballe
Journal:  Int Orthop       Date:  2006-06-08       Impact factor: 3.075

7.  Inferior survival of hydroxyapatite versus titanium-coated cups at 15 years.

Authors:  Maiken Stilling; Ole Rahbek; Kjeld Søballe
Journal:  Clin Orthop Relat Res       Date:  2009-03-28       Impact factor: 4.176

8.  Inferior stabilization of cementless compared with cemented dual-mobility cups in elderly osteoarthrosis patients: a randomized controlled radiostereometry study on 60 patients with 2 years' follow-up.

Authors:  Steffan Tabori-Jensen; Sebastian Breddam Mosegaard; Torben B Hansen; Maiken Stilling
Journal:  Acta Orthop       Date:  2020-02-06       Impact factor: 3.717

9.  Increased risk of revision of acetabular cups coated with hydroxyapatite.

Authors:  Stergios Lazarinis; Johan Kärrholm; Nils P Hailer
Journal:  Acta Orthop       Date:  2010-02       Impact factor: 3.717

10.  A cementless, elastic press-fit socket with and without screws.

Authors:  Dean Pakvis; Joan Luites; Gijs van Hellemondt; Maarten Spruit
Journal:  Acta Orthop       Date:  2012-10       Impact factor: 3.717

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.