Literature DB >> 15585807

Impact of ambient lighting intensity and duration on the signal-to-noise ratio of images from photostimulable phosphor plates processed using DenOptix and ScanX systems.

R Ramamurthy1, C F Canning, J P Scheetz, A G Farman.   

Abstract

OBJECTIVES: To evaluate the impact on photostimulable phosphor (PSP) image signal-to-noise ratio (SNR) of pre-scanning ambient lighting exposures.
METHOD: PSP imaging plates (IPs) were exposed to different radiation exposures to achieve flat field images. The exposed IPs were subjected variously to visible light of different intensities (300, 150 or 20 lux) for durations ranging from < 10 s to 120 s. They were processed using laser scanners from two systems for further comparison (DenOptix versus ScanX). Histogram analysis was performed in each case and mean pixel value and its standard deviation were used as surrogates to assess SNR. Statistical methods applied included analysis of variance with Tukey honestly significant difference test for pair wise comparisons. The a priori alpha was set at P < or = 0.05.
RESULTS: SNR decreased with increased duration and intensity of pre-scanning light exposure. Lower X-ray exposures resulted in decreased signal resulting in reduced SNR, and increased the need to reduce ambient lighting. No statistically significant differences were found comparing ScanX and DenOptix digital imaging systems in terms of SNR.
CONCLUSION: Reduced ambient lighting is preferred for handling IPs prior to processing in the laser scanner.

Entities:  

Mesh:

Year:  2004        PMID: 15585807     DOI: 10.1259/dmfr/91373164

Source DB:  PubMed          Journal:  Dentomaxillofac Radiol        ISSN: 0250-832X            Impact factor:   2.419


  6 in total

1.  The effect of delayed scanning of storage phosphor plates on occlusal caries detection.

Authors:  E Sogur; B G Baksi; A Mert
Journal:  Dentomaxillofac Radiol       Date:  2012-01-26       Impact factor: 2.419

2.  Effect of alternative photostimulable phosphor plates erasing times on subjective digital image quality.

Authors:  D P Melo; A Dos Anjos Pontual; S M de Almeida; P S F Campos; M C Alves; G M Tosoni
Journal:  Dentomaxillofac Radiol       Date:  2010-01       Impact factor: 2.419

3.  Enterprise-wide implementation of digital radiography in oral and maxillofacial imaging: the University of Florida Dentistry System.

Authors:  Madhu K Nair; James C Pettigrew; Jeffrey S Loomis; Robert E Bates; Stephen Kostewicz; Boyd Robinson; Jean Sweitzer; Teresa A Dolan
Journal:  J Digit Imaging       Date:  2008-09-03       Impact factor: 4.056

4.  Definition, classification and retrospective analysis of photostimulable phosphor image artefacts and errors in intraoral dental radiography.

Authors:  Armağan Çalışkan; A Pinar Sumer
Journal:  Dentomaxillofac Radiol       Date:  2017-02-17       Impact factor: 2.419

5.  Analysis of image defects in digital intraoral radiography based on photostimulable phosphor plates.

Authors:  Masayasu Tashiro; Atsutoshi Nakatani; Kazutaka Sugiura; Eiji Nakayama
Journal:  Oral Radiol       Date:  2022-08-10       Impact factor: 1.882

6.  Analysis of photostimulable phosphor image plate artifacts and their prevalence.

Authors:  Sara Mohamed Elkhateeb; Ashwag Yagoub Aloyouny; Mohamed Mohamed Saeed Omer; Soad Mahmoud Mansour
Journal:  World J Clin Cases       Date:  2022-01-14       Impact factor: 1.337

  6 in total