Literature DB >> 15585803

Using a flat-panel detector in high resolution cone beam CT for dental imaging.

R Baba1, K Ueda, M Okabe.   

Abstract

OBJECTIVES: Cone beam CT (CBCT) requires a two-dimensional X-ray detector. In the several CBCT systems developed for dental imaging, detection has been by the combination of an X-ray image intensifier and charge-coupled device (CCD) camera. In this paper, we propose a new CBCT system in which the detector is of the flat-panel type and evaluate its performance in dental imaging.
METHODS: We developed a prototype CBCT that has a flat-panel-type detector. The detector consists of a CsI scintillator screen and a photosensor array. First, the flat panel detector and image intensifier detector were compared in terms of the signal-to-noise ratio (SNR) of projected images. We then used these data and a theoretical formula to evaluate noise in reconstructed images. Second, reconstructed images of a bar pattern phantom were obtained as a way of evaluating the spatial resolution. Then, reconstructed images of a skull phantom were obtained.
RESULTS: The SNR of the developed system was 1.6 times as high as that of a system with an image intensifier detector of equal detector pitch. The system was capable of resolving a 0.35 mm pattern and its field of view almost completely encompassed that of an image intensifier detector which is used in dentomaxillofacial imaging. The fine spatial resolution of the detector led to images in which the structural details of a skull phantom were clearly visible.
CONCLUSIONS: The system's isotropically fine resolution will lead to improved precision in dental diagnosis and surgery. The next stage of our research will be the development of a flat panel detector system with a high frame acquisition rate.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15585803     DOI: 10.1259/dmfr/87440549

Source DB:  PubMed          Journal:  Dentomaxillofac Radiol        ISSN: 0250-832X            Impact factor:   2.419


  22 in total

1.  Radiological examination of the articular eminence morphology using cone beam CT.

Authors:  M A Sümbüllü; F Cağlayan; H M Akgül; A B Yilmaz
Journal:  Dentomaxillofac Radiol       Date:  2011-11-10       Impact factor: 2.419

2.  Evaluation of vascular supply with cone-beam computed tomography during intraarterial chemotherapy for a skull base tumor.

Authors:  Reiichi Ishikura; Kumiko Ando; Yuki Nagami; Satoshi Yamamoto; Koui Miura; Ajaya Raj Pande; Tosyiko Yamano; Shozo Hirota; Norio Nakao
Journal:  Radiat Med       Date:  2006-06

Review 3.  State-of-the-art on cone beam CT imaging for preoperative planning of implant placement.

Authors:  Maria Eugenia Guerrero; Reinhilde Jacobs; Miet Loubele; Filip Schutyser; Paul Suetens; Daniel van Steenberghe
Journal:  Clin Oral Investig       Date:  2006-02-16       Impact factor: 3.573

4.  Cone beam breast CT with a high pitch (75 μm), thick (500 μm) scintillator CMOS flat panel detector: visibility of simulated microcalcifications.

Authors:  Youtao Shen; Yuncheng Zhong; Chao-Jen Lai; Tianpeng Wang; Chris C Shaw
Journal:  Med Phys       Date:  2013-10       Impact factor: 4.071

5.  Penalized-Likelihood Reconstruction With High-Fidelity Measurement Models for High-Resolution Cone-Beam Imaging.

Authors:  Steven Tilley; Matthew Jacobson; Qian Cao; Michael Brehler; Alejandro Sisniega; Wojciech Zbijewski; J Webster Stayman
Journal:  IEEE Trans Med Imaging       Date:  2018-04       Impact factor: 10.048

Review 6.  Classification and numbering of teeth in multi-slice CT images using wavelet-Fourier descriptor.

Authors:  Mohammad Hosntalab; Reza Aghaeizadeh Zoroofi; Ali Abbaspour Tehrani-Fard; Gholamreza Shirani
Journal:  Int J Comput Assist Radiol Surg       Date:  2009-07-29       Impact factor: 2.924

7.  Accuracy assessment of the axial images obtained from cone beam computed tomography.

Authors:  Francine Kühl Panzarella; J L C Junqueira; L B Oliveira; N S de Araújo; C Costa
Journal:  Dentomaxillofac Radiol       Date:  2011-09       Impact factor: 2.419

8.  [Design and optimization of a cone-beam CT system for extremity imaging].

Authors:  Kun Ma; Mingqiang Li; Xi Tao; Dong Zeng; Yongbo Wang; Zhaoying Bian; Ziquan Wei; Gaofeng Chen; Qianjin Feng; Jianhua Ma; Jing Huang
Journal:  Nan Fang Yi Ke Da Xue Xue Bao       Date:  2018-11-30

9.  Determination of optimum exposure parameters for dentoalveolar structures of the jaws using the CB MercuRay system with cluster signal-to-noise analysis.

Authors:  Warangkana Weerawanich; Mayumi Shimizu; Yohei Takeshita; Kazutoshi Okamura; Shoko Yoshida; Gainer R Jasa; Kazunori Yoshiura
Journal:  Oral Radiol       Date:  2018-09-14       Impact factor: 1.852

10.  Cone beam computed tomography and low-dose multislice computed tomography in orthodontics and dentistry: a comparative evaluation on image quality and radiation exposure.

Authors:  E Hofmann; M Schmid; M Lell; U Hirschfelder
Journal:  J Orofac Orthop       Date:  2014-08-28       Impact factor: 1.938

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.