R Baba1, K Ueda, M Okabe. 1. Central Research Laboratory, Hitachi, Ltd., Tokyo, Japan. r-baba@crl.hitachi.co.jp
Abstract
OBJECTIVES: Cone beam CT (CBCT) requires a two-dimensional X-ray detector. In the several CBCT systems developed for dental imaging, detection has been by the combination of an X-ray image intensifier and charge-coupled device (CCD) camera. In this paper, we propose a new CBCT system in which the detector is of the flat-panel type and evaluate its performance in dental imaging. METHODS: We developed a prototype CBCT that has a flat-panel-type detector. The detector consists of a CsI scintillator screen and a photosensor array. First, the flat panel detector and image intensifier detector were compared in terms of the signal-to-noise ratio (SNR) of projected images. We then used these data and a theoretical formula to evaluate noise in reconstructed images. Second, reconstructed images of a bar pattern phantom were obtained as a way of evaluating the spatial resolution. Then, reconstructed images of a skull phantom were obtained. RESULTS: The SNR of the developed system was 1.6 times as high as that of a system with an image intensifier detector of equal detector pitch. The system was capable of resolving a 0.35 mm pattern and its field of view almost completely encompassed that of an image intensifier detector which is used in dentomaxillofacial imaging. The fine spatial resolution of the detector led to images in which the structural details of a skull phantom were clearly visible. CONCLUSIONS: The system's isotropically fine resolution will lead to improved precision in dental diagnosis and surgery. The next stage of our research will be the development of a flat panel detector system with a high frame acquisition rate.
OBJECTIVES: Cone beam CT (CBCT) requires a two-dimensional X-ray detector. In the several CBCT systems developed for dental imaging, detection has been by the combination of an X-ray image intensifier and charge-coupled device (CCD) camera. In this paper, we propose a new CBCT system in which the detector is of the flat-panel type and evaluate its performance in dental imaging. METHODS: We developed a prototype CBCT that has a flat-panel-type detector. The detector consists of a CsI scintillator screen and a photosensor array. First, the flat panel detector and image intensifier detector were compared in terms of the signal-to-noise ratio (SNR) of projected images. We then used these data and a theoretical formula to evaluate noise in reconstructed images. Second, reconstructed images of a bar pattern phantom were obtained as a way of evaluating the spatial resolution. Then, reconstructed images of a skull phantom were obtained. RESULTS: The SNR of the developed system was 1.6 times as high as that of a system with an image intensifier detector of equal detector pitch. The system was capable of resolving a 0.35 mm pattern and its field of view almost completely encompassed that of an image intensifier detector which is used in dentomaxillofacial imaging. The fine spatial resolution of the detector led to images in which the structural details of a skull phantom were clearly visible. CONCLUSIONS: The system's isotropically fine resolution will lead to improved precision in dental diagnosis and surgery. The next stage of our research will be the development of a flat panel detector system with a high frame acquisition rate.
Authors: Maria Eugenia Guerrero; Reinhilde Jacobs; Miet Loubele; Filip Schutyser; Paul Suetens; Daniel van Steenberghe Journal: Clin Oral Investig Date: 2006-02-16 Impact factor: 3.573
Authors: Steven Tilley; Matthew Jacobson; Qian Cao; Michael Brehler; Alejandro Sisniega; Wojciech Zbijewski; J Webster Stayman Journal: IEEE Trans Med Imaging Date: 2018-04 Impact factor: 10.048
Authors: Francine Kühl Panzarella; J L C Junqueira; L B Oliveira; N S de Araújo; C Costa Journal: Dentomaxillofac Radiol Date: 2011-09 Impact factor: 2.419
Authors: Kun Ma; Mingqiang Li; Xi Tao; Dong Zeng; Yongbo Wang; Zhaoying Bian; Ziquan Wei; Gaofeng Chen; Qianjin Feng; Jianhua Ma; Jing Huang Journal: Nan Fang Yi Ke Da Xue Xue Bao Date: 2018-11-30