Literature DB >> 15584525

Monte carlo simulation of the Leksell Gamma Knife: II. Effects of heterogeneous versus homogeneous media for stereotactic radiosurgery.

Vadim Moskvin1, Robert Timmerman, Colleen DesRosiers, Marcus Randall, Paul DesRosiers, Phil Dittmer, Lech Papiez.   

Abstract

The absence of electronic equilibrium in the vicinity of bone-tissue or air-tissue heterogeneity in the head can misrepresent deposited dose with treatment planning algorithms that assume all treatment volume as homogeneous media. In this paper, Monte Carlo simulation (PENELOPE) and measurements with a specially designed heterogeneous phantom were applied to investigate the effect of air-tissue and bone-tissue heterogeneity on dose perturbation with the Leksell Gamma Knife. The dose fall-off near the air-tissue interface caused by secondary electron disequilibrium leads to overestimation of dose by the vendor supplied treatment planning software (GammaPlan) at up to 4 mm from an interface. The dose delivered to the target area away from an air-tissue interface may be underestimated by up to 7% by GammaPlan due to overestimation of attenuation of photon beams passing through air cavities. While the underdosing near the air-tissue interface cannot be eliminated with any plug pattern, the overdosage due to under-attenuation of the photon beams in air cavities can be eliminated by plugging the sources whose beams intersect the air cavity. Little perturbation was observed next to bone-tissue interfaces. Monte Carlo results were confirmed by measurements. This study shows that the employed Monte Carlo treatment planning is more accurate for precise dosimetry of stereotactic radiosurgery with the Leksell Gamma Knife for targets in the vicinity of air-filled cavities.

Entities:  

Mesh:

Year:  2004        PMID: 15584525     DOI: 10.1088/0031-9155/49/21/003

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  17 in total

1.  Interlaced x-ray microplanar beams: a radiosurgery approach with clinical potential.

Authors:  F Avraham Dilmanian; Zhong Zhong; Tigran Bacarian; Helene Benveniste; Pantaleo Romanelli; Ruiliang Wang; Jeremy Welwart; Tetsuya Yuasa; Eliot M Rosen; David J Anschel
Journal:  Proc Natl Acad Sci U S A       Date:  2006-06-07       Impact factor: 11.205

Review 2.  Microbeam radiosurgery using synchrotron-generated submillimetric beams: a new tool for the treatment of brain disorders.

Authors:  David J Anschel; Alberto Bravin; Pantaleo Romanelli
Journal:  Neurosurg Rev       Date:  2010-11-19       Impact factor: 3.042

3.  Considering inhomogeneities in Gamma Knife treatment planning: Factors affecting the loss of prescription dose coverage.

Authors:  William N Duggar; Rui He; Rahul Bhandari; Madhava Kanakamedala; Bart Morris; Roberto Rey-Dios; Srinivasan Vijayakumar; Claus Chunli Yang
Journal:  J Radiosurg SBRT       Date:  2020

4.  A comparison of the convolution and TMR10 treatment planning algorithms for Gamma Knife® radiosurgery.

Authors:  Peter Fallows; Gavin Wright; Natalie Harrold; Peter Bownes
Journal:  J Radiosurg SBRT       Date:  2018

5.  Impact of tissue heterogeneity correction on Gamma Knife stereotactic radiosurgery of acoustic neuromas.

Authors:  Gabrielle W Peters; Christopher J Tien; Veronica Chiang; James Yu; James E Hansen; Sanjay Aneja
Journal:  J Radiosurg SBRT       Date:  2021

Review 6.  Monte Carlo methods for device simulations in radiation therapy.

Authors:  Hyojun Park; Harald Paganetti; Jan Schuemann; Xun Jia; Chul Hee Min
Journal:  Phys Med Biol       Date:  2021-09-14       Impact factor: 4.174

7.  Study of a spherical phantom for Gamma knife dosimetry.

Authors:  Dengsong Zhu; Carlos Austerlitz; Sidi Benhabib; Helvecio Mota; Ron R Allison; Diana Campos
Journal:  J Appl Clin Med Phys       Date:  2010-04-17       Impact factor: 2.102

8.  MAGAT gel and EBT2 film-based dosimetry for evaluating source plugging-based treatment plan in Gamma Knife stereotactic radiosurgery.

Authors:  Gopishankar Natanasabapathi; Vivekanandhan Subbiah; Shashank Sharad Kale; Goura Kishor Rath; S Senthilkumaran; Sanjay Thulkar; Vellaiyan Subramani; M A Laviraj; Raj Kishor Bisht; A K Mahapatra
Journal:  J Appl Clin Med Phys       Date:  2012-11-08       Impact factor: 2.102

9.  Gamma Knife radiosurgery with CT image-based dose calculation.

Authors:  Andy Yuanguang Xu; Jagdish Bhatnagar; Greg Bednarz; Ajay Niranjan; Douglas Kondziolka; John Flickinger; L Dade Lunsford; M Saiful Huq
Journal:  J Appl Clin Med Phys       Date:  2015-11-08       Impact factor: 2.102

10.  Dose differences between the three dose calculation algorithms in Leksell GammaPlan.

Authors:  Andy Yuanguang Xu; Jagdish Bhatnagar; Greg Bednarz; Ajay Niranjan; John Flickinger; L Dade Lunsford; M Saiful Huq
Journal:  J Appl Clin Med Phys       Date:  2014-09-08       Impact factor: 2.102

View more