Literature DB >> 1558239

Instrumented evaluation of knee laxity: a comparison of five arthrometers.

A F Anderson1, R B Snyder, C F Federspiel, A B Lipscomb.   

Abstract

We performed a prospective study on 50 subjects with normal knees and 50 patients with chronic unilateral disruption of the anterior cruciate ligament. In a randomized testing sequence, both groups were examined with five arthrometers: the MEDmetric KT-1000, the Stryker Knee Laxity Tester, the Acufex Knee Signature System, the Dyonics Dynamic Cruciate Tester, and the Genucom Knee Analysis System. Each examination was performed according to protocol with the knee at 30 degrees of flexion. The total anterior laxity measurements of the normal subjects using the Dyonics Dynamic Cruciate Tester and Acufex Knee Signature System were approximately half of the KT-1000, Stryker, and Genucom values. A comparison of the side-to-side measurements revealed no statistically significant difference in the values of the five arthrometers. However, the Genucom showed an unacceptably high number of normal subjects with laxity values that suggested an anterior cruciate ligament tear. Total anterior laxity measurements of the anterior cruciate ligament deficient knees were almost twice those of normal knees with each device except the Genucom. Comparison of the mean side-to-side difference in the patients with ACL deficiency demonstrated statistically significant differences in the values recorded with the five arthrometers. The side-to-side difference was greatest with the KT-1000 and least for the KSS. In the 89 N Lachman test, the KT-1000 and Stryker demonstrated the highest diagnostic accuracy. The maximum manual test improved the accuracy of each device. This study establishes the total anterior laxity measurements cannot be generalized from one device to another in either group of subjects.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Year:  1992        PMID: 1558239     DOI: 10.1177/036354659202000207

Source DB:  PubMed          Journal:  Am J Sports Med        ISSN: 0363-5465            Impact factor:   6.202


  28 in total

1.  Objective evaluation of anterior knee laxity; comparison of the KT-1000 and GNRB® arthrometers.

Authors:  Michel Collette; Julie Courville; Marc Forton; Bertrand Gagnière
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2012-01-10       Impact factor: 4.342

2.  Combined anterior and rotational knee laxity measurements improve the diagnosis of anterior cruciate ligament injuries.

Authors:  C Mouton; D Theisen; T Meyer; H Agostinis; C Nührenbörger; D Pape; R Seil
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2015-08-30       Impact factor: 4.342

3.  Effect of Trunk Position on Anterior Tibial Displacement Measured by the KT-1000 in Uninjured Subjects.

Authors:  W G Webright; D H Perrin; B M Gansneder
Journal:  J Athl Train       Date:  1998-07       Impact factor: 2.860

4.  In vivo laxity of stable versus anterior cruciate ligament-injured knees using a navigation system: a comparative study.

Authors:  Eun Kyoo Song; Jong Keun Seon; Sang Jin Park; Chang Ich Hur; Dam Seon Lee
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2009-04-10       Impact factor: 4.342

5.  Side differences in the anatomy of human knee joints.

Authors:  Jens Dargel; Janna Feiser; Martina Gotter; Dietmar Pennig; Jürgen Koebke
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2009-07-25       Impact factor: 4.342

6.  Medial tibiofemoral-joint stiffness in males and females across the lifespan.

Authors:  Patricia Aronson; Arie Rijke; Jay Hertel; Christopher D Ingersoll
Journal:  J Athl Train       Date:  2014 May-Jun       Impact factor: 2.860

7.  Knee-laxity measurements examined by a left-hand- and a right-hand-dominant physiotherapist, in patients with anterior cruciate ligament injuries and healthy controls.

Authors:  Ninni Sernert; Janett Helmers; Catarina Kartus; Lars Ejerhed; Jüri Kartus
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2007-06-20       Impact factor: 4.342

8.  Stress radiography in the diagnosis of anterior cruciate ligament deficiency.

Authors:  G L Garcés; E Perdomo; A Guerra; R Cabrera-Bonilla
Journal:  Int Orthop       Date:  1995       Impact factor: 3.075

9.  The MacIntosh lateral substitution reconstruction for anterior cruciate deficiency.

Authors:  K Osterman; U M Kujala; J Kivimäki; H Osterman
Journal:  Int Orthop       Date:  1993       Impact factor: 3.075

10.  Bilateral medial tibiofemoral joint stiffness in full extension and 20 degrees of knee flexion.

Authors:  Patricia A Aronson; Arie M Rijke; Christopher D Ingersoll
Journal:  J Athl Train       Date:  2008 Apr-Jun       Impact factor: 2.860

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.