Literature DB >> 15580844

Comparison of computer display monitors for computed radiography diagnostic application in a radiology PACS.

L Sim1, K Manthey, P Esdaile, M Benson.   

Abstract

A study to compare the performance of the following display monitors for application as PACS CR diagnostic workstations is described. 1. Diagnostic quality, 3 megapixel, 21 inch monochrome LCD monitors. 2. Commercial grade, 2 megapixel, 20 inch colour LCD monitors. Two sets of fifty radiological studies each were presented separately to five radiologists on two occasions, using different displays on each occasion. The two sets of radiological studies were CR of the chest, querying the presence of pneumothorax, and CR of the wrist, querying the presence of a scaphoid fracture. Receiver Operating Characteristic (ROC) curves were constructed for diagnostic performance for each presentation. Areas under the ROC curves (AUC) for diagnosis using different monitors were compared for each image set and the following results obtained: Set 1: Monochrome AUC = 0.873 +/- 0.026; Colour AUC = 0.831 +/- 0.032; Set 2: Monochrome AUC = 0.945 +/- 0.014; Colour AUC = 0.931 +/- 0.019; Differences in AUC were attributed to the different monitors. While not significant at a 95% confidence level, the results have supported a cautious approach to consideration of the use of commercial grade LCD colour monitors for diagnostic application.

Entities:  

Mesh:

Year:  2004        PMID: 15580844     DOI: 10.1007/bf03178674

Source DB:  PubMed          Journal:  Australas Phys Eng Sci Med        ISSN: 0158-9938            Impact factor:   1.430


  3 in total

1.  Comparison of color LCD and medical-grade monochrome LCD displays in diagnostic radiology.

Authors:  Håkan Geijer; Mats Geijer; Lillemor Forsberg; Susanne Kheddache; Patrik Sund
Journal:  J Digit Imaging       Date:  2007-06       Impact factor: 4.056

2.  Digital radiography with computerized conventional monitors compared to medical monitors in vertical root fracture diagnosis.

Authors:  Maryam Tofangchiha; Mamak Adel; Mahin Bakhshi; Mahsa Esfehani; Pantea Nazeman; Mojgan Ghorbani Elizeyi; Amir Javadi
Journal:  Iran Endod J       Date:  2013-01-20

3.  Technical and radiological image quality comparison of different liquid crystal displays for radiology.

Authors:  Francina Em Dams; K Y Esther Leung; Pieter Hm van der Valk; Marc Cjm Kock; Jeroen Bosman; Sjoerd P Niehof
Journal:  Med Devices (Auckl)       Date:  2014-10-31
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.