The argument for the use of Metasul as an articulation surface in total hip replacement.

Lawrence D Dorr1, William T Long, Leighellen Sirianni, Martha Campana, Zhinian Wan.   

Abstract

Metasul metal-on-metal articulations have been used for 15 years in approximately 300,000 total hip replacements. We have used Metasul articulations in three clinical studies and have shown clinical success as measured by Harris hip scores and patient self-assessment; we also have had the usual mechanical complications. The only complications have been mechanical, including two cup loosenings and 24 dislocations in a total of 582 patients (619 hips; 3.8%) who had Metasul articulations and were included in these studies. In the randomized study, the group who had Metasul articulations had no clinical results or complications different from the control ceramic-on-polyethylene group. Authors of retrieval results in the literature report low annual linear wear rates and no consequences of elevated Co ion levels. Currently, the scientific evidence of the results of using the Metasul articulation would recommend its continued use in any patient who does not have compromised renal function.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15577470     DOI: 10.1097/01.blo.0000150343.66755.79

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  8 in total

1.  Large-diameter metal-on-metal total hip arthroplasty: dislocation infrequent but survivorship poor.

Authors:  Adolph V Lombardi; Keith R Berend; Michael J Morris; Joanne B Adams; Michael A Sneller
Journal:  Clin Orthop Relat Res       Date:  2014-11-04       Impact factor: 4.176

2.  Failure of the Durom Metasul acetabular component.

Authors:  William T Long; Manish Dastane; Michael J Harris; Zhinian Wan; Lawrence D Dorr
Journal:  Clin Orthop Relat Res       Date:  2009-09-02       Impact factor: 4.176

3.  Metal-on-metal: history, state of the art (2010).

Authors:  Philippe Triclot
Journal:  Int Orthop       Date:  2011-01-14       Impact factor: 3.075

Review 4.  The clinical performance of metal-on-metal as an articulation surface in total hip replacement.

Authors:  William T Long
Journal:  Iowa Orthop J       Date:  2005

5.  Corrosion at the cone/taper interface leads to failure of large-diameter metal-on-metal total hip arthroplasties.

Authors:  Heiko Meyer; Tina Mueller; Gesine Goldau; Kathrin Chamaon; Marcel Ruetschi; Christoph H Lohmann
Journal:  Clin Orthop Relat Res       Date:  2012-11       Impact factor: 4.176

Review 6.  Comparative assessment of implantable hip devices with different bearing surfaces: systematic appraisal of evidence.

Authors:  Art Sedrakyan; Sharon-Lise T Normand; Stefan Dabic; Samantha Jacobs; Stephen Graves; Danica Marinac-Dabic
Journal:  BMJ       Date:  2011-11-29

7.  Halo and spillover effect illustrations for selected beneficial medical devices and drugs.

Authors:  Brent D Kerger; Autumn Bernal; Dennis J Paustenbach; Gavin Huntley-Fenner
Journal:  BMC Public Health       Date:  2016-09-15       Impact factor: 3.295

Review 8.  Increased Mortality in Metal-on-Metal versus Non-Metal-on-Metal Primary Total Hip Arthroplasty at 10 Years and Longer Follow-Up: A Systematic Review and Meta-Analysis.

Authors:  B G Pijls; J M T A Meessen; J W Schoones; M Fiocco; H J L van der Heide; A Sedrakyan; R G H H Nelissen
Journal:  PLoS One       Date:  2016-06-13       Impact factor: 3.240

  8 in total