Literature DB >> 15576175

The resistance of polyvinylpyrrolidone-iodine-poly(-caprolactone) blends to adherence of Escherichia coli.

David S Jones1, Jasmina Djokic, Sean P Gorman.   

Abstract

In this study, the resistance of biodegradable biomaterials, composed of blends of poly(-caprolactone) (PCL) and the polymeric antimicrobial complex, polyvinylpyrrolidone-iodine (PVP-I) to the adherence of a clinical isolate of Escherichia coli is described. Blends of PCL composed of a range of high (50,000 g mol(-1)) to low (5000 g mol(-1)) molecular weight ratios of polymer and either devoid of or containing PVP-I (1% w/w) were prepared by solvent evaporation. Following incubation (4 h), there was no relationship between m. wt. ratio of PCL in films devoid of PVP-I and adherence of E. coli. Conversely, microbial adherence to PCL containing PVP-I decreased as the ratio of high:low m. wt. polymer was decreased and was approximately 1000 fold lower than that to comparator films devoid of PVP-I. Following periods of immersion of PVP-I containing PCL films under sink conditions in phosphate buffered saline, subsequent adherence of E. coli was substantially reduced for 2 days (40:60 m. wt. ratio) and 6 days (100:0 m. wt. ratio). Concurrent exposure of PCL and E. coli to sub-minimum inhibitory concentrations (sub-MIC) of PVP-I significantly reduced microbial adherence to the biomaterial; however, the molecular weight ratio of PCL did not affect this outcome. Pretreatment of PCL with similar sub-MIC of PVP-I prior to inclusion within the microbial adherence assay significantly decreased the subsequent adherence of E. coli. Greatest reduction in adherence was observed following treatment of PCL (40:60 m. wt. ratio) with 0.0156% w/w PVP-I. In conclusion, this study has illustrated the utility of PVP-I as a suitable therapeutic agent for incorporation within PCL as a novel biomaterial. Due to the combined antimicrobial and biodegradable properties, these biomaterials offer a promising strategy for the reduction in medical device related infection.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15576175     DOI: 10.1016/j.biomaterials.2004.06.001

Source DB:  PubMed          Journal:  Biomaterials        ISSN: 0142-9612            Impact factor:   12.479


  6 in total

1.  A novel planar flow cell for studies of biofilm heterogeneity and flow-biofilm interactions.

Authors:  Wei Zhang; Tadas S Sileika; Cheng Chen; Yang Liu; Jisun Lee; Aaron I Packman
Journal:  Biotechnol Bioeng       Date:  2011-08-01       Impact factor: 4.530

2.  Effect of uropathogens on in vitro encrustation of polyurethane double J ureteral stents.

Authors:  Nandakumar Venkatesan; Sunil Shroff; Karthik Jeyachandran; Mukesh Doble
Journal:  Urol Res       Date:  2010-06-02

3.  Antibacterial activity of chitosan-based matrices on oral pathogens.

Authors:  Aparna R Sarasam; Phoebe Brown; Sharukh S Khajotia; John J Dmytryk; Sundararajan V Madihally
Journal:  J Mater Sci Mater Med       Date:  2007-08-15       Impact factor: 3.896

4.  Comparison of the adherence of E.Coli and S. Aureus to ten different prosthetic mesh grafts: In vitro experimental study.

Authors:  Bulent Gungor; Saban Esen; Ali Gök; Havva Yılmaz; Zafer Malazgirt; Hakan Leblebicioğlu
Journal:  Indian J Surg       Date:  2010-08-26       Impact factor: 0.656

Review 5.  Antimicrobial polymers with metal nanoparticles.

Authors:  Humberto Palza
Journal:  Int J Mol Sci       Date:  2015-01-19       Impact factor: 5.923

6.  In vivo Analysis of the Resistance of the Meshes to Escherichia coli Infection.

Authors:  Xinsen Xu; Ming Zhan; Xinxing Li; Tao Chen; Linhua Yang
Journal:  Front Surg       Date:  2021-06-24
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.