Literature DB >> 15570379

Effect of exposure dose on the replication fidelity and profile of very high aspect ratio microchannels in SU-8.

Jun Zhang1, Mary B Chan-Park, Samuel R Conner.   

Abstract

We are interested in using SU-8 dense gratings with very high aspect ratio microchannels as the master mold for fabrication of child molds needed for replication. For such applications, the sidewall taper angle and mask replication fidelity of SU-8 are very important. Increasing the exposure time was experimentally observed to decrease the width of the microchannel and the sidewall angle of SU-8 bars. A new diffraction-refraction-reflection model was also developed. The calculated microchannel width and sidewall angle at high exposure dose agreed well with the experimentally observed values indicating that reflection at the silicon substrate was significant. The larger than calculated actual microchannel width for low exposure dose was shown to be due to leaching of unreacted SU-8 in the developer. Dense gratings of high aspect ratio SU-8 bars separated by high aspect ratio (19.1) microchannels were also demonstrated.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15570379     DOI: 10.1039/b403304c

Source DB:  PubMed          Journal:  Lab Chip        ISSN: 1473-0189            Impact factor:   6.799


  7 in total

1.  A "dry and wet hybrid" lithography technique for multilevel replication templates: Applications to microfluidic neuron culture and two-phase global mixing.

Authors:  Debjani Paul; Laure Saias; Jean-Cedric Pedinotti; Max Chabert; Sebastien Magnifico; Antoine Pallandre; Bertrand De Lambert; Claude Houdayer; Bernard Brugg; Jean-Michel Peyrin; Jean-Louis Viovy
Journal:  Biomicrofluidics       Date:  2011-04-14       Impact factor: 2.800

2.  Controlled incremental filtration: a simplified approach to design and fabrication of high-throughput microfluidic devices for selective enrichment of particles.

Authors:  Sean C Gifford; Angela M Spillane; Seth M Vignes; Sergey S Shevkoplyas
Journal:  Lab Chip       Date:  2014-09-25       Impact factor: 6.799

3.  Photolithographic fabrication of microapertures with well-defined, three-dimensional geometries for suspended lipid membrane studies.

Authors:  Christopher A Baker; Leonard K Bright; Craig A Aspinwall
Journal:  Anal Chem       Date:  2013-09-16       Impact factor: 6.986

4.  Effect of cross sectional geometry on PDMS micro peristaltic pump performance: comparison of SU-8 replica molding vs. micro injection molding.

Authors:  Neil J Graf; Michael T Bowser
Journal:  Analyst       Date:  2013-10-07       Impact factor: 4.616

5.  Microchannel contacting of crystalline silicon solar cells.

Authors:  James Bullock; Hiroki Ota; Hanchen Wang; Zhaoran Xu; Mark Hettick; Di Yan; Christian Samundsett; Yimao Wan; Stephanie Essig; Monica Morales-Masis; Andrés Cuevas; Ali Javey
Journal:  Sci Rep       Date:  2017-08-22       Impact factor: 4.379

6.  Label-free Rapid Viable Enrichment of Circulating Tumor Cell by Photosensitive Polymer-based Microfilter Device.

Authors:  Yoon-Tae Kang; Il Doh; Jiyoung Byun; Hee Jin Chang; Young-Ho Cho
Journal:  Theranostics       Date:  2017-07-22       Impact factor: 11.556

7.  Fabrication of Tapered 3D Microstructure Arrays Using Dual-Exposure Lithography (DEL).

Authors:  Venkatakrishnan Rengarajan; Junnan Geng; Yu Huang
Journal:  Micromachines (Basel)       Date:  2020-09-29       Impact factor: 2.891

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.