Treatment of internal carotid artery aneurysms with a covered stent: experience in 24 patients with mid-term follow-up results.

Isil Saatci1, H Saruhan Cekirge, M Halil Ozturk, Anil Arat, Fikret Ergungor, Zeki Sekerci, Engin Senveli, Uygur Er, Sami Turkoglu, Osman E Ozcan, Tuncalp Ozgen.   

Abstract

BACKGROUND AND
PURPOSE: We present our preliminary experience, including mid-term angiographic and clinical follow-up results, with an alternative technique for the endovascular treatment of intracranial aneurysms in a series of patients. This new method, previously described in anecdotal case reports, consists of endovascular deployment of an artificial vessel graft (stent graft or covered stent) in the parent vessel to exclude the intracranial aneurysm sac from circulation.
METHODS: Twenty-five internal carotid artery (ICA) aneurysms in 24 patients were successfully treated by using a Jostent coronary stent graft deployed in the parent artery across the aneurysm neck. All except four aneurysms were extradural, located in the petrous or cavernous portion of the ICA. The four intradural aneurysms were located in the carotico-ophthalmic region. Seventeen aneurysms in 16 patients occurred posttraumatically, secondary to motor vehicle accidents or surgical injury.
RESULTS: Twenty-three aneurysms were immediately excluded from circulation after stent graft placement. In two aneurysms, a slow contrast material filling (endoleak) into the aneurysm cavity was observed immediately after treatment. One was thrombosed, as shown by late control angiography; in the other one, a second larger bare stent was used to appose the stent graft's distal end to the ICA wall, thus sealing the endoleak into the distal graft. No technical adverse event, including vessel dissection, vessel perforation, or thromboembolism, occurred with or without clinical consequence. No mortality or morbidity developed during or after the procedure, including the follow-up period. Two-year control angiography in one patient, 1.5-year control angiography in two patients, 1-year control angiography in six patients, and 6-month control angiography in 12 patients were performed, revealing reconstruction of the ICA with no aneurysm recanalization. All symptoms resolved after treatment in the patients who had initially presented with mass effect.
CONCLUSION: Initial anatomic, clinical and mid-term follow-up results in this small series of patients are encouraging. This technique has been proved to have potential in the reconstructive treatment of intracranial aneurysms. Further research and development are needed to optimize the stent graft technology for the cerebrovascular system.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15569740      PMCID: PMC8148739     

Source DB:  PubMed          Journal:  AJNR Am J Neuroradiol        ISSN: 0195-6108            Impact factor:   3.825


  30 in total

1.  Coronary stent grafts covered by a polytetrafluoroethylene membrane.

Authors:  M Elsner; W Auch-Schwelk; M Britten; D H Walter; V Schächinger; A M Zeiher
Journal:  Am J Cardiol       Date:  1999-08-01       Impact factor: 2.778

2.  Bare stent-graft technique: a new method of endoluminal vascular reconstruction for the treatment of giant and fusiform aneurysms.

Authors:  Civan Islak; Naci Kocer; Sait Albayram; Osman Kizilkilic; Omer Uzma; Oktay Cokyuksel
Journal:  AJNR Am J Neuroradiol       Date:  2002-10       Impact factor: 3.825

3.  Intracranial stent placement to trap an extruded coil during endovascular aneurysm treatment: technical note.

Authors:  R D Fessler; A J Ringer; A I Qureshi; L R Guterman; L N Hopkins
Journal:  Neurosurgery       Date:  2000-01       Impact factor: 4.654

Review 4.  Autologous vein-covered stent repair of a cervical internal carotid artery pseudoaneurysm: technical case report.

Authors:  T R Marotta; C Buller; D Taylor; C Morris; T Zwimpfer
Journal:  Neurosurgery       Date:  1998-02       Impact factor: 4.654

5.  Six months clinical, angiographic, and IVUS follow-up after PTFE graft stent implantation in native coronary arteries.

Authors:  G Lukito; P Vandergoten; L Jaspers; P Dendale; E Benit
Journal:  Acta Cardiol       Date:  2000-08       Impact factor: 1.718

6.  Treatment of traumatic aneurysms and arteriovenous fistulas of the skull base by using endovascular stents.

Authors:  G Redekop; T Marotta; A Weill
Journal:  J Neurosurg       Date:  2001-09       Impact factor: 5.115

7.  Endovascular treatment of ophthalmic segment aneurysms with Guglielmi detachable coils.

Authors:  D Roy; J Raymond; A Bouthillier; M W Bojanowski; R Moumdjian; G L'Espérance
Journal:  AJNR Am J Neuroradiol       Date:  1997-08       Impact factor: 3.825

8.  Coronary artery aneurysm after stent implantation: acute and long-term results after percutaneous treatment with a stent graft.

Authors:  Paolo Rubartelli; Giacomo Terzi; Lorenzo Borgo; Corinna Giachero
Journal:  Ital Heart J       Date:  2002-03

9.  Covered stent grafts: role in intervention of coronary arteries and degenerated vein grafts.

Authors:  Volker Schächinger; Andreas M Zeiher
Journal:  Z Kardiol       Date:  2002

10.  Cerebral Aneurysm Multicenter European Onyx (CAMEO) trial: results of a prospective observational study in 20 European centers.

Authors:  Andrew J Molyneux; Saruhan Cekirge; Isil Saatci; Gyula Gál
Journal:  AJNR Am J Neuroradiol       Date:  2004-01       Impact factor: 3.825

View more
  59 in total

1.  Follow-up of endovascular treatment of direct carotid-cavernous fistulas.

Authors:  Márcio C Pedro Marques; José Guilherme M Pereira Caldas; Dárcio R Nalli; Jose Roberto F Fonseca; Roberto G Nogueira; Nitamar Abdala
Journal:  Neuroradiology       Date:  2010-05-12       Impact factor: 2.804

2.  Treatment of ruptured ICA during transsphenoidal surgery. Two different endovascular strategies in two cases.

Authors:  S B Ghatge; D B Modi
Journal:  Interv Neuroradiol       Date:  2010-03-25       Impact factor: 1.610

3.  Management of pseudoaneurysms in the intracranial segment of the internal carotid artery with covered stents specially designed for use in the intracranial vasculature: technical notes.

Authors:  Ming-Hua Li; Bu-Lang Gao; Yong-Li Wang; Chun Fang; Yong-Dong Li
Journal:  Neuroradiology       Date:  2006-08-31       Impact factor: 2.804

4.  Development of in vivo tissue-engineered autologous tissue-covered stents (biocovered stents).

Authors:  Yasuhide Nakayama; Yue-Min Zhou; Hatsue Ishibashi-Ueda
Journal:  J Artif Organs       Date:  2007-09-20       Impact factor: 1.731

5.  Partially thrombosed intracranial aneurysms presenting with mass effect: long-term clinical and imaging follow-up after endovascular treatment.

Authors:  S P Ferns; W J van Rooij; M Sluzewski; R van den Berg; C B L M Majoie
Journal:  AJNR Am J Neuroradiol       Date:  2010-03-18       Impact factor: 3.825

6.  Flow diversion in the treatment of carotid injury and carotid-cavernous fistula after transsphenoidal surgery.

Authors:  Daniela Iancu; Cheemum Lum; Muhammad E Ahmed; Rafael Glikstein; Marlise P Dos Santos; Howard Lesiuk; Mohamed Labib; Amin B Kassam
Journal:  Interv Neuroradiol       Date:  2015-05-26       Impact factor: 1.610

7.  Fabrication of Small Caliber Stent-grafts Using Electrospinning and Balloon Expandable Bare Metal Stents.

Authors:  Susheil Uthamaraj; Brandon J Tefft; Soumen Jana; Ota Hlinomaz; Manju Kalra; Amir Lerman; Dan Dragomir-Daescu; Gurpreet S Sandhu
Journal:  J Vis Exp       Date:  2016-10-26       Impact factor: 1.355

8.  Using a covered stent for large cerebral aneurysms treated with stent-assisted coiling.

Authors:  Chun Fang; Chuan-Sen Liu; Ya-Ping Xiao; Mei Zhao; Jian-Min Zhang; Ming-Hua Li; Yue-Qi Zhu
Journal:  Interv Neuroradiol       Date:  2015-05-13       Impact factor: 1.610

9.  Pipeline embolization device in aneurysmal subarachnoid hemorrhage.

Authors:  J P Cruz; C O'Kelly; M Kelly; J H Wong; W Alshaya; A Martin; J Spears; T R Marotta
Journal:  AJNR Am J Neuroradiol       Date:  2012-10-11       Impact factor: 3.825

10.  Unruptured large and giant carotid artery aneurysms presenting with cranial nerve palsy: comparison of clinical recovery after selective aneurysm coiling and therapeutic carotid artery occlusion.

Authors:  W J van Rooij; M Sluzewski
Journal:  AJNR Am J Neuroradiol       Date:  2008-02-22       Impact factor: 3.825