Literature DB >> 10496448

Coronary stent grafts covered by a polytetrafluoroethylene membrane.

M Elsner1, W Auch-Schwelk, M Britten, D H Walter, V Schächinger, A M Zeiher.   

Abstract

In a prospective observational study, 40 patients were treated with coronary stent grafts covered by a polytetrafluoroethylene membrane. These devices may be regarded as therapy of choice for acute coronary rupture; treatment of conventional in-stent restenosis was not associated with a favorable outcome, whereas the promising results in degenerated vein grafts warrant a randomized, controlled trial.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10496448     DOI: 10.1016/s0002-9149(99)00289-1

Source DB:  PubMed          Journal:  Am J Cardiol        ISSN: 0002-9149            Impact factor:   2.778


  23 in total

1.  Bare stent-graft technique: a new method of endoluminal vascular reconstruction for the treatment of giant and fusiform aneurysms.

Authors:  Civan Islak; Naci Kocer; Sait Albayram; Osman Kizilkilic; Omer Uzma; Oktay Cokyuksel
Journal:  AJNR Am J Neuroradiol       Date:  2002-10       Impact factor: 3.825

2.  Treatment of ruptured ICA during transsphenoidal surgery. Two different endovascular strategies in two cases.

Authors:  S B Ghatge; D B Modi
Journal:  Interv Neuroradiol       Date:  2010-03-25       Impact factor: 1.610

3.  Initial experience with intracranial stent-graft use. Technical notes.

Authors:  I C Duncan; P A Fourie
Journal:  Interv Neuroradiol       Date:  2005-10-25       Impact factor: 1.610

4.  Management of pseudoaneurysms in the intracranial segment of the internal carotid artery with covered stents specially designed for use in the intracranial vasculature: technical notes.

Authors:  Ming-Hua Li; Bu-Lang Gao; Yong-Li Wang; Chun Fang; Yong-Dong Li
Journal:  Neuroradiology       Date:  2006-08-31       Impact factor: 2.804

5.  Development of in vivo tissue-engineered autologous tissue-covered stents (biocovered stents).

Authors:  Yasuhide Nakayama; Yue-Min Zhou; Hatsue Ishibashi-Ueda
Journal:  J Artif Organs       Date:  2007-09-20       Impact factor: 1.731

6.  Fabrication of Small Caliber Stent-grafts Using Electrospinning and Balloon Expandable Bare Metal Stents.

Authors:  Susheil Uthamaraj; Brandon J Tefft; Soumen Jana; Ota Hlinomaz; Manju Kalra; Amir Lerman; Dan Dragomir-Daescu; Gurpreet S Sandhu
Journal:  J Vis Exp       Date:  2016-10-26       Impact factor: 1.355

7.  Treatment of a coronary artery aneurysm by use of a covered stent graft - a case report.

Authors:  Fuat Gundoğdu; Sakir Arslan; Eyup Buyukkaya; Huseyin Senocak
Journal:  Int J Angiol       Date:  2007

8.  Traumatic carotid cavernous fistula: failure of endovascular treatment with two stent-grafts.

Authors:  G La Tessa; L Pasqualetto; G Catalano; M Marino; C Gargano; L Cirillo; L Zenna; E Montemarano; G Sirabella
Journal:  Interv Neuroradiol       Date:  2006-02-10       Impact factor: 1.610

9.  Utility of covered stents for extracranial internal carotid artery stenosis.

Authors:  Barbaros E Cil; Erhan Akpinar; Bora Peynircioglu; Saruhan Cekirge
Journal:  AJNR Am J Neuroradiol       Date:  2004-08       Impact factor: 3.825

10.  Stent-graft placement for wide-neck aneurysm of the vertebrobasilar junction.

Authors:  Michael A Burbelko; Lyudmyla A Dzyak; Nykolay A Zorin; Sergey P Grigoruk; Volodymyr A Golyk
Journal:  AJNR Am J Neuroradiol       Date:  2004-04       Impact factor: 3.825

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.