Literature DB >> 15567539

A biomechanical study comparing cortical onlay allograft struts and plates in the treatment of periprosthetic femoral fractures.

Darrin Wilson1, Hanspeter Frei, Bassam A Masri, Thomas R Oxland, Clive P Duncan.   

Abstract

BACKGROUND: Periprosthetic femoral fractures with well-fixed femoral components can be difficult to manage and internal fixation is usually necessary. This study was designed to determine the effect of cable plate, strut allograft and combined plate and strut allograft fixations of periprosthetic femoral fractures.
METHODS: A transverse fracture at the level of the tip of the femoral stem was simulated in six cadaveric femurs. The fracture was fixed with a plate-strut graft construct with and without proximal screws, a plate only construct with and without proximal screws and with both anterior and lateral struts grafts of 12 cm or 20 cm in length. The intact femur and the six constructs were tested using anteroposterior and axial loads to simulate the forces at the hip during gait. The interfragmentary motions were measured with an optoelectronic camera system.
FINDINGS: The highest median interfragmentary translations were observed with the plate only construct without proximal screws. No significant differences in median translations were found between the combined plate-strut and the strut-graft alone constructs. Median interfragmentary rotations were largest with the plate only construct and lowest with the plate-strut constructs.
INTERPRETATION: The best fracture fixation was achieved with the combined plate and strut graft constructs particularly in combination with the two unicortical screws above the fracture. The plate only constructs may not provide sufficient fixation stability in rotation for the simulated transverse fracture. The within-construct interfragmentary motions were not significantly different except for the plate only constructs. This suggests that the fixation construct type is the determining factor of interfragmentary motion.

Entities:  

Mesh:

Year:  2005        PMID: 15567539     DOI: 10.1016/j.clinbiomech.2004.08.008

Source DB:  PubMed          Journal:  Clin Biomech (Bristol, Avon)        ISSN: 0268-0033            Impact factor:   2.063


  15 in total

1.  High union rates of locking compression plating with cortical strut allograft for type B1 periprosthetic femoral fractures.

Authors:  Ingwon Yeo; Kee-Hyung Rhyu; Sang-Min Kim; Yoon-Soo Park; Seung-Jae Lim
Journal:  Int Orthop       Date:  2016-01-13       Impact factor: 3.075

Review 2.  [Ipsilateral THA after stemmed TKA: Risk of interprosthetic fracture?].

Authors:  J Dexel; A Hartmann; J Pyrc; K-P Günther; J Lützner
Journal:  Orthopade       Date:  2015-07       Impact factor: 1.087

3.  The biomechanical analysis of three plating fixation systems for periprosthetic femoral fracture near the tip of a total hip arthroplasty.

Authors:  James P Lever; Rad Zdero; Markku T Nousiainen; James P Waddell; Emil H Schemitsch
Journal:  J Orthop Surg Res       Date:  2010-07-23       Impact factor: 2.359

4.  Tangential Bicortical Locked Fixation Improves Stability in Vancouver B1 Periprosthetic Femur Fractures: A Biomechanical Study.

Authors:  Gregory S Lewis; Cyrus T Caroom; Hwabok Wee; Darin Jurgensmeier; Shane D Rothermel; Michelle A Bramer; John Spence Reid
Journal:  J Orthop Trauma       Date:  2015-10       Impact factor: 2.512

Review 5.  The management of type B1 periprosthetic femoral fractures: when to fix and when to revise.

Authors:  Adam T Yasen; Fares S Haddad
Journal:  Int Orthop       Date:  2014-12-16       Impact factor: 3.075

6.  Strut Onlay Allograft in Revision Arthroplasty: Osseous Union and Clinical Outcome.

Authors:  Dietmar Dammerer; Alexander Wurm; Clemens Frischhut; Johannes Petersen; Miar Ouaret; Michael Liebensteiner
Journal:  In Vivo       Date:  2022 Jan-Feb       Impact factor: 2.155

7.  A review of periprosthetic femoral fractures associated with total hip arthroplasty.

Authors:  Daniel Marsland; Simon C Mears
Journal:  Geriatr Orthop Surg Rehabil       Date:  2012-09

8.  Biomechanical comparison of 2 different locking plate fixation methods in vancouver b1 periprosthetic femur fractures.

Authors:  Joshua D Pletka; Daniel Marsland; Stephen M Belkoff; Simon C Mears; Stephen L Kates
Journal:  Geriatr Orthop Surg Rehabil       Date:  2011-03

9.  Influence of PEEK Coating on Hip Implant Stress Shielding: A Finite Element Analysis.

Authors:  Jesica Anguiano-Sanchez; Oscar Martinez-Romero; Hector R Siller; Jose A Diaz-Elizondo; Eduardo Flores-Villalba; Ciro A Rodriguez
Journal:  Comput Math Methods Med       Date:  2016-03-14       Impact factor: 2.238

10.  USE OF CORTICAL STRUCTURAL HOMOLOGOUS BONE GRAFT IN FEMORAL RECONSTRUCTIVE SURGERY.

Authors:  Milton Valdomiro Roos; Bruno Dutra Roos; Taís Stedile Busin Giora; Thiago Martins Taglietti
Journal:  Rev Bras Ortop       Date:  2015-12-12
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.