Literature DB >> 15567102

Effect of surface roughness of ground titanium on initial cell adhesion.

Her-Hsiung Huang1, Chun-Te Ho, Tzu-Hsin Lee, Tien-Ling Lee, Ko-Kaung Liao, Fang-Lung Chen.   

Abstract

The effect of surface roughness of ground Ti on the initial adhesion of osteoblast-like U-2 OS cells was investigated in this study. Different numbers (#120, #600, and #1500) of SiC sandpaper and two Al2O3 polishing powder (0.3 and 1 microm) were used to prepare the metal specimens with varying degrees of surface roughness. Surface roughness (Ra) was measured by profilometry. Surface topography was observed using an atomic force microscope. MTT (3-[4,5-dimethylthiazol-2-yl]-2,5-diphenyl tetrazolium bromide) assay was used to measure the optical density (OD) of specimens after 2 h of cell incubation. The OD value was analyzed by one-way ANOVA for analyzing the factor of surface roughness. Crystal violet staining technique was used to characterize the cell spreading. Results showed that the specimen of #1500 Ti (Ra: 0.15 microm) had the highest OD value. The specimens polished with 0.3 and 1 microm Al2O3 powder (Ra: 0.05 and 0.07 microm) exhibited the worst cell adhesion behavior. Contact guidance of cells could be observed on the rougher #600 and #120 specimens (Ra: 0.33 and 1.20 microm). This study concludes that the surface roughness (Ra: 0.05-1.20 microm) of ground Ti has a highly significant influence on the initial adhesion of osteoblast-like U-2 OS cells. The ground Ti with an Ra of 0.15 microm shows the optimal cell adhesion behavior with respect to either the rougher or smoother specimens.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15567102     DOI: 10.1016/j.bioeng.2004.05.001

Source DB:  PubMed          Journal:  Biomol Eng        ISSN: 1389-0344


  23 in total

1.  Effects of surface microtopography on the assembly of the osteoclast resorption apparatus.

Authors:  Dafna Geblinger; Christian Zink; Nicholas D Spencer; Lia Addadi; Benjamin Geiger
Journal:  J R Soc Interface       Date:  2011-11-16       Impact factor: 4.118

2.  Nano-topography sensing by osteoclasts.

Authors:  Dafna Geblinger; Lia Addadi; Benjamin Geiger
Journal:  J Cell Sci       Date:  2010-04-07       Impact factor: 5.285

3.  Nerve growth factor-immobilized polypyrrole: bioactive electrically conducting polymer for enhanced neurite extension.

Authors:  Natalia Gomez; Christine E Schmidt
Journal:  J Biomed Mater Res A       Date:  2007-04       Impact factor: 4.396

Review 4.  Modern biomaterials: a review - bulk properties and implications of surface modifications.

Authors:  Paul Roach; David Eglin; Kirsty Rohde; Carole C Perry
Journal:  J Mater Sci Mater Med       Date:  2007-04-19       Impact factor: 3.896

5.  Laser micro-grooved, Arginine-Glycine-Apspartic acid (RGD) coated dental implants, a 5 years radiographic follow-up.

Authors:  Mohamed Ahmed Alkhodary
Journal:  Int J Health Sci (Qassim)       Date:  2014-10

6.  AFM study of morphology and mechanical properties of a chimeric spider silk and bone sialoprotein protein for bone regeneration.

Authors:  Sílvia Gomes; Keiji Numata; Isabel B Leonor; João F Mano; Rui L Reis; David L Kaplan
Journal:  Biomacromolecules       Date:  2011-03-31       Impact factor: 6.988

7.  Assessment of human gingival fibroblast interaction with dental implant abutment materials.

Authors:  Vygandas Rutkunas; Virginija Bukelskiene; Vaidotas Sabaliauskas; Evaldas Balciunas; Mangirdas Malinauskas; Daiva Baltriukiene
Journal:  J Mater Sci Mater Med       Date:  2015-03-25       Impact factor: 3.896

8.  Bone is not essential for osteoclast activation.

Authors:  Karen Fuller; Jade L Ross; Kinga A Szewczyk; Raymond Moss; Tim J Chambers
Journal:  PLoS One       Date:  2010-09-17       Impact factor: 3.240

9.  In vitro cytocompatibility evaluation of a thermoresponsive NIPAAm-MMA copolymeric surface using L929 cells.

Authors:  Viji Mary Varghese; Vidya Raj; K Sreenivasan; T V Kumary
Journal:  J Mater Sci Mater Med       Date:  2010-01-22       Impact factor: 3.896

10.  Integrin-mediated osteoblastic adhesion on a porous manganese-incorporated TiO2 coating prepared by plasma electrolytic oxidation.

Authors:  Zhenxiang Zhang; Beibei Gu; Wei Zhu; Lixian Zhu
Journal:  Exp Ther Med       Date:  2013-07-04       Impact factor: 2.447

View more