Literature DB >> 15566905

Comparison of safety and efficacy of the early injection of atropine during dobutamine stress echocardiography with the conventional protocol.

Jeane M Tsutsui1, Altamiro F F Osório, F Abio C Lario, Daniela R A Fernandes, Gustavo Sodre, José L Andrade, José A F Ramires, Wilson Mathias.   

Abstract

Although dobutamine-atropine stress echocardiography (DASE) is an established method for evaluating patients who have coronary artery disease (CAD), it can increase test duration and a patient's exposure to large doses of dobutamine. New protocols, including the early injection of atropine during dobutamine stress echocardiography (EA-DSE), have been proposed to decrease test duration. This study compared the safety, efficacy, and accuracy of EA-DSE with those of DASE. We retrospectively evaluated 3,163 patients who underwent DASE and 1,664 patients who underwent EA-DSE over a period of 12 years. In EA-DSE, atropine at a dose </=2 mg was started with 20 microg/kg/min of dobutamine if heart rate was <100 beats/min. Diagnostic accuracy for detecting CAD (>50% stenosis) was assessed in patients who underwent quantitative angiography </=3 months of stress testing. The dobutamine dose used in EA-DSE was smaller than that used in DASE (31 +/- 6 vs 36 +/- 6 microg/kg/min, p <0.0001), although the atropine dose was larger (0.8 +/- 0.5 vs 0.5 +/- 0.25 mg, p <0.0001). EA-DSE resulted in a significantly shorter duration of dobutamine infusion (12.4 +/- 2.0 vs 14.6 +/- 2.5 minutes, p <0.0001), more diagnostic studies (88% vs 81%, p <0.0001), and a lower incidence of minor adverse effects than did DASE. The rate of major adverse effects was similar in the 2 protocols. Sensitivities, specificities, positive predictive values, negative predictive values, and accuracies for detecting CAD were 84%, 90%, 93%, 76%, and 86% for EA-DSE and 86%, 78%, 84%, 79%, and 82% for DASE, respectively (p = NS). Therefore, EA-DSE is a safe and effective alternative to DASE and had a similar accuracy for the detection of CAD.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15566905     DOI: 10.1016/j.amjcard.2004.07.141

Source DB:  PubMed          Journal:  Am J Cardiol        ISSN: 0002-9149            Impact factor:   2.778


  8 in total

Review 1.  Serious and potentially life threatening complications of cardiac stress testing: Physiological mechanisms and management strategies.

Authors:  Vasken Dilsizian; Henry Gewirtz; Nicholas Paivanas; Anastasia N Kitsiou; Fadi G Hage; Nathan E Crone; Ronald G Schwartz
Journal:  J Nucl Cardiol       Date:  2015-05-15       Impact factor: 5.952

2.  Safety and cardiac chronotropic responsiveness to the early injection of atropine during dobutamine stress echocardiography in the elderly.

Authors:  J M Tsutsui; F Cerqueira Lario; D R Fernandes; I Kowatsch; J C Sbano; J A Franchini Ramires; W Mathias
Journal:  Heart       Date:  2005-03-29       Impact factor: 5.994

3.  Comparison between accelerated and conventional dobutamine stress protocols for myocardial perfusion scintigraphy.

Authors:  Aurora Issa; Andrea De Lorenzo; Bernardo Oliveira; Marcos Pellini; Ronaldo Lima
Journal:  Int J Cardiovasc Imaging       Date:  2011-12-21       Impact factor: 2.357

4.  Reduced adverse effects with an accelerated dobutamine stress protocol compared with the conventional protocol: a prospective, randomized myocardial perfusion scintigraphy study.

Authors:  Ronaldo de Souza Leão Lima; Andrea De Lorenzo; Aurora Issa
Journal:  Int J Cardiovasc Imaging       Date:  2007-04-12       Impact factor: 2.357

5.  Low Prevalance of Major Events Adverse to Exercise Stress Echocardiography.

Authors:  Stephanie Macedo Andrade; Caio José Coutinho Leal Telino; Antônio Carlos Sobral Sousa; Enaldo Vieira de Melo; Carla Carolina Cardoso Teixeira; Clarissa Karine Cardoso Teixeira; Jaquiele Santos Santana; Igor Larchert Mota; Carlos José Oliveira de Matos; Joselina Luzia Menezes Oliveira
Journal:  Arq Bras Cardiol       Date:  2016-06-27       Impact factor: 2.000

6.  Prognostic value of dobutamine stress myocardial perfusion echocardiography in patients with known or suspected coronary artery disease and normal left ventricular function.

Authors:  Angele A A Mattoso; Jeane M Tsutsui; Ingrid Kowatsch; Vitória Y L Cruz; João C N Sbano; Henrique B Ribeiro; Roberto Kalil Filho; Thomas R Porter; Wilson Mathias
Journal:  PLoS One       Date:  2017-02-24       Impact factor: 3.240

7.  Stress echocardiography: safety and tolerability.

Authors:  Nada Fennich; Fedoua Ellouali; Salima Abdelali; Assad Chaara; Allal Berrada; Imane Elhajjaji; Rhizlane Cherradi; Saadia Abir; Nawal Doghmi; Mohammed Cherti
Journal:  Cardiovasc Ultrasound       Date:  2013-08-20       Impact factor: 2.062

8.  Feasibility, safety and tolerability of accelerated dobutamine stress echocardiography.

Authors:  Giovanni Minardi; Carla Manzara; Giovanni Pulignano; Paolo G Pino; Herribert Pavaci; Martina Sordi
Journal:  Cardiovasc Ultrasound       Date:  2007-11-21       Impact factor: 2.062

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.