Literature DB >> 15565174

Evaluation of the A&D UA-767 and Welch Allyn Spot Vital Signs noninvasive blood pressure monitors using a blood pressure simulator.

P D Davis1, J L Dennis, R Railton.   

Abstract

The performance of five units of the A&D UA-767 NIBP monitor and five units of the Welch Allyn Spot Vital Signs noninvasive blood pressure monitor was evaluated with the Biotek BP Pump blood pressure simulator under a variety of conditions. Using the simulator to provide a normal blood pressure waveform at 80 bpm over a range of pressures, it was found that the mean bias for the combined results from the A&D monitors was 1.9+/-2.8 mmHg and from the Welch Allyn monitors was 0.7+/-2.4 mmHg. No individual measurement showed a bias greater than 10 mmHg. A bias of greater than 5 mmHg was present in 28 out of 150 measurements for the A&D monitor and 10 out of 150 measurements for the Welch Allyn monitor. These results are comparable with ratings achieved by the instruments when tested previously according to the British Hypertension Society protocol, but testing with a simulator allowed assessment of aspects of performance which were not included in the British Hypertension Society protocol.

Entities:  

Mesh:

Year:  2005        PMID: 15565174     DOI: 10.1038/sj.jhh.1001804

Source DB:  PubMed          Journal:  J Hum Hypertens        ISSN: 0950-9240            Impact factor:   3.012


  5 in total

Review 1.  A procedure for evaluation of non-invasive blood pressure simulators.

Authors:  Gregor Gersak; Ales Zemva; Janko Drnovsek
Journal:  Med Biol Eng Comput       Date:  2009-10-13       Impact factor: 2.602

2.  The Effect of a Community-Based Self-Help Intervention: Korean Americans With Type 2 Diabetes.

Authors:  Miyong T Kim; Kim B Kim; Boyun Huh; Tam Nguyen; Hae-Ra Han; Lee R Bone; David Levine
Journal:  Am J Prev Med       Date:  2015-07-14       Impact factor: 5.043

Review 3.  Point-of-care diagnostics to improve maternal and neonatal health in low-resource settings.

Authors:  Catherine E Majors; Chelsey A Smith; Mary E Natoli; Kathryn A Kundrod; Rebecca Richards-Kortum
Journal:  Lab Chip       Date:  2017-10-11       Impact factor: 6.799

4.  Metabolic Syndrome and Its Components in Young Adults Conceived by ICSI.

Authors:  F Belva; M Bonduelle; S Provyn; R C Painter; H Tournaye; M Roelants; J De Schepper
Journal:  Int J Endocrinol       Date:  2018-05-03       Impact factor: 3.257

5.  Body composition and blood pressure in 6-year-old singletons born after pre-implantation genetic testing for monogenic and structural chromosomal aberrations: a matched cohort study.

Authors:  F Belva; M Roelants; S Kluijfhout; C Winter; F De Schrijver; S Desmyttere; M De Rycke; H Tournaye; I Liebaers; M Bonduelle
Journal:  Hum Reprod Open       Date:  2018-09-01
  5 in total