Literature DB >> 15562854

Composite graft endocarditis: repair with a mechanical prosthesis.

Anil Z Apaydin1, Hakan Posacioglu, Fatih Islamoglu, Kenan Degirmenciler, Isa Durmaz.   

Abstract

We report the case of a 64-year-old man who developed a mediastinal pseudoaneurysm due to severe endocarditis, 2 years after aortic root replacement with a prosthetic composite graft containing a mechanical valve. After a short period of stabilization and antibiotic therapy, the patient underwent surgery. The coronary buttons and the sewing ring of the composite graft were found to be detached from the graft and the annulus, respectively. Re-replacement with a prosthetic composite graft (Dacron graft with a mechanical valve) by the Cabrol procedure was performed. Although the homograft is considered by many surgeons to be the best graft for aortic root replacement, the synthetic composite graft can also be used to treat composite graft endocarditis successfully. The technical aspects of homograft versus synthetic aortic root replacement in patients with endocarditis are discussed briefly.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15562854      PMCID: PMC521777     

Source DB:  PubMed          Journal:  Tex Heart Inst J        ISSN: 0730-2347


  6 in total

1.  Aortic valve replacement for active infectious endocarditis in 108 patients. A comparison of freehand allograft valves with mechanical prostheses and bioprostheses.

Authors:  D Haydock; B Barratt-Boyes; T Macedo; J W Kirklin; E Blackstone
Journal:  J Thorac Cardiovasc Surg       Date:  1992-01       Impact factor: 5.209

2.  Operation for infective endocarditis: results after implantation of mechanical valves.

Authors:  R Bauernschmitt; H G Jakob; C F Vahl; R Lange; S Hagl
Journal:  Ann Thorac Surg       Date:  1998-02       Impact factor: 4.330

3.  Advantage of autograft and homograft valve replacement for complex aortic valve endocarditis.

Authors:  K Niwaya; C J Knott-Craig; K Santangelo; M M Lane; K Chandrasekaran; R C Elkins
Journal:  Ann Thorac Surg       Date:  1999-06       Impact factor: 4.330

4.  Acute endocarditis treated with radical debridement and implantation of mechanical or stented bioprosthetic devices.

Authors:  J Aagaard; P V Andersen
Journal:  Ann Thorac Surg       Date:  2001-01       Impact factor: 4.330

5.  Replacing the ascending aorta and aortic valve for acute prosthetic valve endocarditis: is using prosthetic material contraindicated?

Authors:  Christian Hagl; Jan D Galla; Steven L Lansman; Daniel Fink; Carol A Bodian; David Spielvogel; Randall B Griepp
Journal:  Ann Thorac Surg       Date:  2002-11       Impact factor: 4.330

6.  Reoperative cryopreserved root and ascending aorta replacement for acute aortic prosthetic valve endocarditis.

Authors:  Bruce W Lytle; Joseph F Sabik; Eugene H Blackstone; Lars G Svensson; Gosta B Pettersson; Delos M Cosgrove
Journal:  Ann Thorac Surg       Date:  2002-11       Impact factor: 4.330

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.