BACKGROUND: The use of prosthetic material (rather than a homograft) for ascending aorta/aortic valve replacement (Bentall procedure) in cases of acute prosthetic valve endocarditis is controversial. We report favorable results using this technique almost exclusively (a homograft was used in only 3 patients with hematological problems) during a 12-year interval.
METHODS: Twenty-eight patients (55 +/- 14 years; 22 male) underwent a Bentall procedure for acute prosthetic valve endocarditis between 1988 and 2000. Twenty-five patients had undergone previous aortic valve replacement (1 with concomitant mitral valve replacement, 4 with coronary artery bypass grafting), and 3 had had a previous Bentall operation. The median interval between initial surgery and reoperation was 13 months (range, 1 to 106). Sixty-eight percent of operations were urgent or emergencies. Ninety-three percent of patients had significant aortic regurgitation; complete annuloaortic dehiscence occurred in 71%, and in 57%, an abscess was found. Causative organisms were identified in 25 of 28 patients: Staphylococcus epidermidis (9), Staphylococcus aureus (7), Streptococcus viridans (6), Pseudomonas (2), and Legionella (1).
RESULTS: Twenty-three patients had mechanical and 5 had biological valves implanted during the Bentall procedure. Hypothermic circulatory arrest was used in 64%. Hospital mortality was 11%: there was one intraoperative death, and two before discharge (one cardiac, one sepsis). Eighty-nine percent survived without stroke. During follow-up (median, 44.5 months; complete in 92%), 1 patient died of recurrent endocarditis at 4 months.
CONCLUSIONS: These results indicate that prosthetic root replacement may be superior to use of a homograft for acute aortic prosthetic valve endocarditis, with only a 4% incidence of recurrent endocarditis and reoperation.

Entities:  

Mesh:

Year:  2002        PMID: 12440665     DOI: 10.1016/s0003-4975(02)04142-5

Source DB:  PubMed          Journal:  Ann Thorac Surg        ISSN: 0003-4975            Impact factor:   4.330


  12 in total

1.  Homograft Aortic Root Replacement with Saphenous Vein Graft Hemi-Cabrol for Prosthetic Aortic Valve Endocarditis.

Authors:  Ioannis Dimarakis; Wilfred J Wooldridge; Isaac Kadir
Journal:  Aorta (Stamford)       Date:  2015-04-01

2.  [S2 Guideline for diagnosis and therapy of infectious endocarditis].

Authors:  C K Naber
Journal:  Z Kardiol       Date:  2004-12

3.  Reoperation for composite graft infection after aortic root replacement.

Authors:  Hirokazu Murayama; Soichi Asano; Momoko Yanai; Masaki Yamamoto; Katsuhiko Tatsuno
Journal:  Jpn J Thorac Cardiovasc Surg       Date:  2005-09

4.  Native valve endocarditis due to a novel strain of Legionella.

Authors:  Meghan M Pearce; Nicole Theodoropoulos; Gary A Noskin; John P Flaherty; Mary E Stemper; Teresa Aspeslet; Nicholas P Cianciotto; Kurt D Reed
Journal:  J Clin Microbiol       Date:  2011-07-27       Impact factor: 5.948

Review 5.  Surgical treatment for aortic periannular abscess/pseudoaneurysm caused by infective endocarditis.

Authors:  Kenji Okada; Yutaka Okita
Journal:  Gen Thorac Cardiovasc Surg       Date:  2012-11-17

6.  Treatment of prosthetic valve endocarditis complicated by destruction of the aortic annulus.

Authors:  Yuki Okamoto; Kenji Minakata; Tomoyuki Yunoki; Masatake Katsu; Shin-ichiro Chino; Masahiko Matsumoto
Journal:  Gen Thorac Cardiovasc Surg       Date:  2011-08-18

7.  Composite graft endocarditis: repair with a mechanical prosthesis.

Authors:  Anil Z Apaydin; Hakan Posacioglu; Fatih Islamoglu; Kenan Degirmenciler; Isa Durmaz
Journal:  Tex Heart Inst J       Date:  2004

Review 8.  Stentless aortic valve replacement: an update.

Authors:  Junjiro Kobayashi
Journal:  Vasc Health Risk Manag       Date:  2011-06-02

9.  Valve selection in aortic valve endocarditis.

Authors:  Sossio Perrotta; Yana Zubrytska
Journal:  Kardiochir Torakochirurgia Pol       Date:  2016-09-30

10.  Acute aortic dissection type A discloses Corpus alienum.

Authors:  Aron Frederik Popov; Mersa Mohammed Baryalei; Jan Dieter Schmitto; Jose Hinz; Christoph Hermann Wiese; Björn Raab; Philipp Kolat; Friedrich Albert Schoendube; Ralf Seipelt
Journal:  J Cardiothorac Surg       Date:  2009-01-02       Impact factor: 1.637

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.