Literature DB >> 15562477

Simultaneous MRI acquisition of blood volume, blood flow, and blood oxygenation information during brain activation.

Yihong Yang1, Hong Gu, Elliot A Stein.   

Abstract

Simultaneous acquisition of complementary functional hemodynamic indices reflecting different aspects of brain activity would be a valuable tool for functional brain-imaging studies offering enhanced detection power and improved data interpretation. As such, a new MRI technique is presented that is able to achieve concurrent acquisition of three hemodynamic images based primarily on the changes of cerebral blood volume, blood flow, and blood oxygenation, respectively, associated with brain activation. Specifically, an inversion recovery pulse sequence has been designed to measure VASO (vascular space occupancy), ASL (arterial spin labeling) perfusion, and BOLD (blood-oxygenation-level-dependent) signals in a single scan. The MR signal characteristics in this sequence were analyzed, and image parameters were optimized for the simultaneous acquisition of these functional images. The feasibility and efficacy of the new technique were assessed by brain activation experiments with visual stimulation paradigms. Experiments on healthy volunteers showed that this technique provided efficient image acquisition, and thus higher contrast-to-noise ratio per unit time, compared with conventional techniques collecting these functional images separately. In addition, it was demonstrated that the proposed technique was able to be utilized in event-related functional MRI experiments, with potential advantages of obtaining accurate transient information of the activation-induced hemodynamic responses. (c) 2004 Wiley-Liss, Inc.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15562477     DOI: 10.1002/mrm.20302

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  30 in total

1.  Three-dimensional acquisition of cerebral blood volume and flow responses during functional stimulation in a single scan.

Authors:  Ying Cheng; Peter C M van Zijl; James J Pekar; Jun Hua
Journal:  Neuroimage       Date:  2014-08-23       Impact factor: 6.556

2.  Comparison of spatial and temporal pattern for fMRI obtained with BOLD and arterial spin labeling.

Authors:  A Federspiel; T J Müller; H Horn; C Kiefer; W K Strik
Journal:  J Neural Transm (Vienna)       Date:  2006-04-11       Impact factor: 3.575

3.  Quantitative spatial comparison of diffuse optical imaging with blood oxygen level-dependent and arterial spin labeling-based functional magnetic resonance imaging.

Authors:  Theodore J Huppert; Rick D Hoge; Anders M Dale; Maria A Franceschini; David A Boas
Journal:  J Biomed Opt       Date:  2006 Nov-Dec       Impact factor: 3.170

4.  Applications and limitations of whole-brain MAGIC VASO functional imaging.

Authors:  A Scouten; R T Constable
Journal:  Magn Reson Med       Date:  2007-08       Impact factor: 4.668

5.  Improved cortical-layer specificity of vascular space occupancy fMRI with slab inversion relative to spin-echo BOLD at 9.4 T.

Authors:  Tao Jin; Seong-Gi Kim
Journal:  Neuroimage       Date:  2007-12-08       Impact factor: 6.556

6.  CBF, BOLD, CBV, and CMRO(2) fMRI signal temporal dynamics at 500-msec resolution.

Authors:  Qiang Shen; Hongxia Ren; Timothy Q Duong
Journal:  J Magn Reson Imaging       Date:  2008-03       Impact factor: 4.813

7.  VASO-based calculations of CBV change: accounting for the dynamic CSF volume.

Authors:  A Scouten; R T Constable
Journal:  Magn Reson Med       Date:  2008-02       Impact factor: 4.668

8.  Real-time functional MRI using pseudo-continuous arterial spin labeling.

Authors:  Luis Hernandez-Garcia; Hesamoddin Jahanian; Mark K Greenwald; Jon-Kar Zubieta; Scott J Peltier
Journal:  Magn Reson Med       Date:  2011-03-28       Impact factor: 4.668

9.  In vivo magnetic resonance imaging and spectroscopy. Technological advances and opportunities for applications continue to abound.

Authors:  Peter van Zijl; Linda Knutsson
Journal:  J Magn Reson       Date:  2019-07-09       Impact factor: 2.229

10.  Evaluation of MRI models in the measurement of CMRO2 and its relationship with CBF.

Authors:  Ai-Ling Lin; Peter T Fox; Yihong Yang; Hanzhang Lu; Li-Hai Tan; Jia-Hong Gao
Journal:  Magn Reson Med       Date:  2008-08       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.