Abstract

The synthesis of a molecule, 1-(11-dodecylsulfanyl-undecyl)-[4,4']bipyridinium bromide (1), suitable at the same time to form a covalent bond with gold electrodes of a piezoelectric quartz crystal and to interact with heavy metal ions in aqueous solutions, has been successfully accomplished. A commercial quartz crystal microbalance instrument has been modified in order to perform a Flow-Injection Analysis. The behaviour of the system follows the Kanazawa-Gordon equation as demonstrated by measurements with glucose solutions. The self-assembled layer of 1 onto a gold electrode has been characterised by Atomic Force Microscopy before and after the sensing tests. The sensing performances of the modified gold electrode were investigated by monitoring the frequency variation induced by the presence of heavy metal ions, such as lead, cadmium and mercury, in aqueous media. The explored concentrations ranged between 10(-4) and 10(-2) M and the corresponding frequency variations ranged between 10 and 50 Hz. All responses observed were fast, reproducible and reversible. In particular, the response to mercury appears significantly higher in comparison with the other analytes. To the best of our knowledge, this contribution represents the first example of sensing layer based on bipyridinium receptor showing reversible and, at some extent, differentiated response towards heavy metal ions.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15556366     DOI: 10.1016/j.bios.2004.04.028

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  2 in total

1.  Polymer-grafted QCM chemical sensor and application to heavy metalions real time detection.

Authors:  Luciana Sartore; Marzia Barbaglio; Laura Borgese; Elza Bontempi
Journal:  Sens Actuators B Chem       Date:  2011-07-20       Impact factor: 7.460

2.  Determination of silver(I) by differential pulse voltammetry using a glassy carbon electrode modified with synthesized N-(2-aminoethyl)-4,4'-bipyridine.

Authors:  Maria-Cristina Radulescu; Ana Chira; Medeea Radulescu; Bogdan Bucur; Madalina Petruta Bucur; Gabriel Lucian Radu
Journal:  Sensors (Basel)       Date:  2010-12-13       Impact factor: 3.576

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.