Literature DB >> 15554130

Intensity-based image registration using robust correlation coefficients.

Jeongtae Kim1, Jeffrey A Fessler.   

Abstract

The ordinary sample correlation coefficient is a popular similarity measure for aligning images from the same or similar modalities. However, this measure can be sensitive to the presence of "outlier" objects that appear in one image but not the other, such as surgical instruments, the patient table, etc., which can lead to biased registrations. This paper describes an intensity-based image registration technique that uses a robust correlation coefficient as a similarity measure. Relative to the ordinary sample correlation coefficient, the proposed similarity measure reduces the influence of outliers. We also compared the performance of the proposed method with the mutual information-based method. The robust correlation-based method should be useful for image registration in radiotherapy (KeV to MeV X-ray images) and image-guided surgery applications. We have investigated the properties of the proposed method by theoretical analysis, computer simulations, a phantom experiment, and with functional magnetic resonance imaging data.

Entities:  

Mesh:

Year:  2004        PMID: 15554130     DOI: 10.1109/TMI.2004.835313

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  16 in total

1.  Multimodal image fusion with SIMS: Preprocessing with image registration.

Authors:  Jay Gage Tarolli; Anna Bloom; Nicholas Winograd
Journal:  Biointerphases       Date:  2016-06-14       Impact factor: 2.456

2.  A frequency-based approach to locate common structure for 2D-3D intensity-based registration of setup images in prostate radiotherapy.

Authors:  Reshma Munbodh; Zhe Chen; David A Jaffray; Douglas J Moseley; Jonathan P S Knisely; James S Duncan
Journal:  Med Phys       Date:  2007-07       Impact factor: 4.071

3.  Automated 2D-3D registration of portal images and CT data using line-segment enhancement.

Authors:  Reshma Munbodh; Zhe Chen; David A Jaffray; Douglas J Moseley; Jonathan P S Knisely; James S Duncan
Journal:  Med Phys       Date:  2008-10       Impact factor: 4.071

Review 4.  Deformable medical image registration: a survey.

Authors:  Aristeidis Sotiras; Christos Davatzikos; Nikos Paragios
Journal:  IEEE Trans Med Imaging       Date:  2013-05-31       Impact factor: 10.048

5.  Technical note: deformable image registration on partially matched images for radiotherapy applications.

Authors:  Deshan Yang; S Murty Goddu; Wei Lu; Olga L Pechenaya; Yu Wu; Joseph O Deasy; Issam El Naqa; Daniel A Low
Journal:  Med Phys       Date:  2010-01       Impact factor: 4.071

6.  A coarse-to-fine registration method for three-dimensional MR images.

Authors:  Cuixia Li; Yuanyuan Zhou; Yinghao Li; Shanshan Yang
Journal:  Med Biol Eng Comput       Date:  2021-01-29       Impact factor: 2.602

7.  An effective non-rigid registration approach for ultrasound image based on "demons" algorithm.

Authors:  Yan Liu; H D Cheng; Jianhua Huang; Yingtao Zhang; Xianglong Tang; Jiawei Tian
Journal:  J Digit Imaging       Date:  2013-06       Impact factor: 4.056

8.  Marker-free lung tumor trajectory estimation from a cone beam CT sinogram.

Authors:  Geoffrey D Hugo; Jian Liang; Di Yan
Journal:  Phys Med Biol       Date:  2010-04-14       Impact factor: 3.609

9.  A fast inverse consistent deformable image registration method based on symmetric optical flow computation.

Authors:  Deshan Yang; Hua Li; Daniel A Low; Joseph O Deasy; Issam El Naqa
Journal:  Phys Med Biol       Date:  2008-10-14       Impact factor: 3.609

10.  A finite element method to correct deformable image registration errors in low-contrast regions.

Authors:  Hualiang Zhong; Jinkoo Kim; Haisen Li; Teamour Nurushev; Benjamin Movsas; Indrin J Chetty
Journal:  Phys Med Biol       Date:  2012-05-11       Impact factor: 3.609

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.