Literature DB >> 15553285

The effect of adhesive and flowable composite on postoperative sensitivity: 2-week results.

Jorge Perdigão1, Camillo Anauate-Netto, André R P Carmo, James S Hodges, Hiram J D Cordeiro, Hugo R Lewgoy, Maristela Dutra-Corrêa, Natália Castilhos, Ricardo Amore.   

Abstract

OBJECTIVE: To measure 2-week postoperative sensitivity in Class II composite restorations placed with a self-etching adhesive (Clearfil SE Bond) or a total-etch adhesive (Prime&Bond NT) with or without a flowable composite as cervical increment. METHOD AND MATERIALS: Upon approval by the University of Guarulhos Committee on Human Subjects, 100 restorations were inserted in 46 patients who required Class II restorations in their molars and premolars. Enamel and dentin walls were conditioned with a self-etching primer (for Clearfil SE Bond) or etched with 34% phosphoric acid (for Prime&Bond NT). A 1- to 2-mm-thick increment of a flowable composite (Filtek Flow) was used in the proximal box in 50% of the restorations of each adhesive. Preparations were restored with a packable composite (Surefil). The restorations were evaluated preoperatively and 2 weeks postoperatively for sensitivity to cold, air, and masticatory forces using a visual analog scale. Marginal integrity of the accessible margins was also evaluated. Statistical analysis used a mixed linear model with subject as a random effect.
RESULTS: Ninety-eight teeth from 44 subjects were observed at 2 weeks. The type of adhesive and use of flowable composite had no significant effects or interaction for any of the four outcomes of interest, ie, change from baseline to 2 weeks in sensitivity and response time for the cold or air stimulus. For the air stimulus, the overall average change from baseline was not significant for either sensitivity or response time. For the cold stimulus, the overall average change from baseline was significant for both sensitivity and response time. No case of sensitivity to masticatory forces was observed.
CONCLUSION: No differences in postoperative sensitivity were observed between a self-etch adhesive and a total-etch adhesive at 2 weeks. The use of flowable composite did not decrease postoperative sensitivity.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15553285

Source DB:  PubMed          Journal:  Quintessence Int        ISSN: 0033-6572            Impact factor:   1.677


  9 in total

Review 1.  Flowable Resin Composites: A Systematic Review and Clinical Considerations.

Authors:  Kusai Baroudi; Jean C Rodrigues
Journal:  J Clin Diagn Res       Date:  2015-06-01

2.  Postoperative hypersensitivity in class I resin-based composite restorations in general practice: interim results.

Authors:  Gary S Berkowitz; Allan J Horowitz; Fredrick A Curro; Ronald G Craig; Jonathan A Ship; Donald Vena; Van P Thompson
Journal:  Compend Contin Educ Dent       Date:  2009 Jul-Aug

3.  Clinical performance of a nanofilled resin composite with and without an intermediary layer of flowable composite: a 2-year evaluation.

Authors:  Sebastian Stefanski; Jan W V van Dijken
Journal:  Clin Oral Investig       Date:  2010-11-23       Impact factor: 3.573

Review 4.  Compliance of randomized controlled trials in posterior restorations with the CONSORT statement: a systematic review of methodology.

Authors:  Márcia Rezende; Ana Cristina Rodrigues Martins; Jadson Araújo da Silva; Alessandra Reis; Juliana Larocca de Geus
Journal:  Clin Oral Investig       Date:  2021-09-30       Impact factor: 3.606

5.  Microshear bond strength of self-adhesive composite to ceramic after mechanical, chemical and laser surface treatments.

Authors:  Maryam Ghavam; Marjan Soleimanpour; Sedighe Sadat Hashemikamangar; Hooman Ebrahimi; Mohammad Javad Kharazifard
Journal:  Laser Ther       Date:  2017-12-31

6.  The effect of bonding and surface sealant application on postoperative sensitivity from posterior composites.

Authors:  Neslihan Tekce; Mustafa Demirci; Sultan Aslıhan Gokturk; Safa Tuncer; Emre Ozel; Kansad Pala; Canan Baydemir
Journal:  J Istanb Univ Fac Dent       Date:  2015-10-21

7.  Effect of different adhesive strategies on the post-operative sensitivity of class I composite restorations.

Authors:  Hande Sar Sancakli; Esra Yildiz; Isil Bayrak; Sevda Ozel
Journal:  Eur J Dent       Date:  2014-01

8.  Evaluation of Marginal Adaptation of a Self-Adhering Flowable Composite Resin Liner: A Scanning Electron Microscopic Study.

Authors:  Chava Gayatri; Tanikonda Rambabu; Girija Sajjan; Pravallika Battina; Medapati Suseela Priyadarshini; Beesetty Lakshmi Sowjanya
Journal:  Contemp Clin Dent       Date:  2018-09

9.  Effects of flowable liners on the shrinkage vectors of bulk-fill composites.

Authors:  Dalia Kaisarly; D Meierhofer; M El Gezawi; P Rösch; K H Kunzelmann
Journal:  Clin Oral Investig       Date:  2021-01-27       Impact factor: 3.573

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.