Literature DB >> 15552414

On the relation between the spatial dose integrity and the temporal instability of polymer gel dosimeters.

K Vergote1, Y De Deene, E Vanden Bussche, C De Wagter.   

Abstract

When irradiating a polymer gel dosimeter to relatively high doses, edge enhancing effects (overshoots) may be noticed near dose gradients, resulting in a loss of spatial dose integrity. These overshoots are believed to be a consequence of monomers diffusing into the high-dose region, where they react with long-living macroradicals. Macroradicals may also be responsible for the temporal chemical instability of post-irradiation polymerization that occurs in the polymer gel dosimeter. In this study, a mathematical model is proposed that simulates the edge enhancing effect. The model is based on the hypothesis that the macroradicals are responsible for both the temporal instability and loss of spatial dose integrity. All input parameters for the model are obtained from independent experiments. The edge enhancing effect is studied both experimentally and theoretically for polymer gel dosimeters with various gelatin concentrations. The change in the edge enhancement is also investigated over post-irradiation time. Comparisons between polymer gel measurements and simulations confirm the hypothesis that there is a strong relation between the spatial and temporal instabilities.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15552414     DOI: 10.1088/0031-9155/49/19/005

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  4 in total

1.  Commissioning and benchmarking a 3D dosimetry system for clinical use.

Authors:  Andrew Thomas; Joseph Newton; John Adamovics; Mark Oldham
Journal:  Med Phys       Date:  2011-08       Impact factor: 4.071

Review 2.  Polymer gel dosimetry.

Authors:  C Baldock; Y De Deene; S Doran; G Ibbott; A Jirasek; M Lepage; K B McAuley; M Oldham; L J Schreiner
Journal:  Phys Med Biol       Date:  2010-02-11       Impact factor: 3.609

3.  Basic Properties of a New Polymer Gel for 3D-Dosimetry at High Dose-Rates Typical for FFF Irradiation Based on Dithiothreitol and Methacrylic Acid (MAGADIT): Sensitivity, Range, Reproducibility, Accuracy, Dose Rate Effect and Impact of Oxygen Scavenger.

Authors:  Muzafar Khan; Gerd Heilemann; Wolfgang Lechner; Dietmar Georg; Andreas Georg Berg
Journal:  Polymers (Basel)       Date:  2019-10-19       Impact factor: 4.329

Review 4.  Radiation Dosimetry by Use of Radiosensitive Hydrogels and Polymers: Mechanisms, State-of-the-Art and Perspective from 3D to 4D.

Authors:  Yves De Deene
Journal:  Gels       Date:  2022-09-19
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.