Midplane dose determination using in vivo dose measurements in combination with portal imaging.

D Huyskens1, J Van Dam, A Dutreix.   

Abstract

The possibility of using portal films in combination with semiconductor in vivo measurements for midplane dose distribution is investigated. A general algorithm, using measured entrance and exit doses and available beam data of the Linac, is proposed to derive the midplane dose for symmetrical inhomogeneities. Experimental verification of the algorithm with phantom measurements is performed for different kinds of inhomogeneities (Al, air and cork) and phantom thicknesses from 13 cm to 30 cm. When using only the entrance dose and the exit dose, provided by the diodes on the beam axis, the algorithm predicts for the different inhomogeneities midplane doses in all cases within 1% of the midplane doses measured with an ionization chamber. When using the portal film in combination with entrance and exit dose measurements to estimate the midplane dose in an off-axis position, the calculated midplane doses are within 3% of the midplane doses measured with an ionization chamber. The midplane doses calculated with the algorithm are compared to the midplane doses obtained with simplified calculation methods, i.e. the arithmetical mean and the geometrical mean of the measured entrance and exit doses. The geometrical mean especially seems to give acceptable results (within 5%) and can as such be used as an easy rule of thumb to estimate roughly the midplane dose. Finally, critical considerations on the validity and the precision of the proposed algorithm are given. The present results confirm the possibility of using the portal film for midplane dose distribution determination at the patient level.

Entities:  

Mesh:

Year:  1994        PMID: 15552099     DOI: 10.1088/0031-9155/39/7/003

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  4 in total

1.  Evaluation of relative transmitted dose for a step and shoot head and neck intensity modulated radiation therapy using a scanning liquid ionization chamber electronic portal imaging device.

Authors:  Mohammad Mohammadi; Eva Bezak
Journal:  J Med Phys       Date:  2012-01

2.  Evaluation of off-axis wedge correction factor using diode dosimeters for estimation of delivered dose in external radiotherapy.

Authors:  Mahmoud Allahverdi; Alireza Mohammadkarim; Mahbod Esfehani; Hasanali Nedaie; Alireza Shirazi; Ghazale Geraily
Journal:  J Med Phys       Date:  2012-01

3.  Assessment of a 2D electronic portal imaging devices-based dosimetry algorithm for pretreatment and in-vivo midplane dose verification.

Authors:  Ali Jomehzadeh; Parvaneh Shokrani; Mohammad Mohammadi; Alireza Amouheidari
Journal:  Adv Biomed Res       Date:  2016-11-28

4.  The use of extended dose range film for dosimetric calibration of a scanning liquid-filled ionization chamber electronic portal imaging device.

Authors:  Mohammad Mohammadi; Eva Bezak; Paul Reich
Journal:  J Appl Clin Med Phys       Date:  2006-05-15       Impact factor: 2.102

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.