Dose rate dependence of a PTW diamond detector in the dosimetry of a 6 MV photon beam.

P W Hoban1, M Heydarian, W A Beckham, A H Beddoe.   

Abstract

The dose rate dependence and current/voltage characteristics of a PTW Riga diamond detector in the dosimetry of a 6 MV photon beam have been investigated. Diamond detectors are radiosensitive resistors whose conductivity (i) varies almost in proportion to dose rate and (ii) is almost independent of bias voltage for a constant dose rate. At the recommended bias of +100 V, and also at +200 V, the detector is operating with incomplete charge collection due to the electron-hole recombination time being shorter that the maximum time for an electron to be collected by the anode. As dose rate is varied by changing FSD or depth (changing dose per pulse), detector current and dose rate are related by the expression i alpha Ddelta where delta is approximately 0.98. This manifests itself in an overestimate in percentage depth-dose at a depth of 30 cm of approximately 1% when compared to ionization chamber results. A similar sublinearity is seen when pulse repetition frequency is varied, indicating that the dependence is an on average rather than an instantaneous dose rate. The dose rate dependence is attributed to the reduction in recombination time as dose rate increases.

Entities:  

Mesh:

Substances:

Year:  1994        PMID: 15551563     DOI: 10.1088/0031-9155/39/8/003

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  7 in total

1.  Total scatter factors of small beams: a multidetector and Monte Carlo study.

Authors:  Paolo Francescon; Stefania Cora; Carlo Cavedon
Journal:  Med Phys       Date:  2008-02       Impact factor: 4.071

2.  Correcting lateral response artifacts from flatbed scanners for radiochromic film dosimetry.

Authors:  David Lewis; Maria F Chan
Journal:  Med Phys       Date:  2015-01       Impact factor: 4.071

3.  Silicon diodes as an alternative to diamond detectors for depth dose curves and profile measurements of photon and electron radiation.

Authors:  Christian Scherf; Christiane Peter; Jussi Moog; Jörg Licher; Eugen Kara; Klemens Zink; Claus Rödel; Ulla Ramm
Journal:  Strahlenther Onkol       Date:  2009-08-04       Impact factor: 3.621

4.  Percent depth-dose distribution discrepancies from very small volume ion chambers.

Authors:  Vikren Sarkar; Brian Wang; Hui Zhao; Bart Lynch; Joshua A James; Kiernan T McCullough; Bill J Salter
Journal:  J Appl Clin Med Phys       Date:  2015-03-08       Impact factor: 2.102

5.  Characterization of a plastic dosimeter based on organic semiconductor photodiodes and scintillator.

Authors:  Jessie A Posar; Jeremy Davis; Owen Brace; Paul Sellin; Matthew J Griffith; Olivier Dhez; Dean Wilkinson; Michael L F Lerch; Anatoly Rosenfeld; Marco Petasecca
Journal:  Phys Imaging Radiat Oncol       Date:  2020-06-05

Review 6.  From cultured to uncultured genome sequences: metagenomics and modeling microbial ecosystems.

Authors:  Daniel R Garza; Bas E Dutilh
Journal:  Cell Mol Life Sci       Date:  2015-08-09       Impact factor: 9.261

7.  Clinical radiation therapy measurements with a new commercial synthetic single crystal diamond detector.

Authors:  Wolfram U Laub; Richard Crilly
Journal:  J Appl Clin Med Phys       Date:  2014-11-08       Impact factor: 2.102

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.