Literature DB >> 15548966

Urgent need for normalization of corneal graft quality controls in French eye banks.

Gilles Thuret1, Chloé Manissolle, Sophie Acquart, Olivier Garraud, Lydia Campos-Guyotat, Jean Maugery, Philippe Gain.   

Abstract

BACKGROUND: Assessment of corneal tissue quality before graft is mainly based upon the determination of endothelial cell density (ECD) by eye banks. These cells are responsible for corneal transparency, and ECD correlates with graft survival. In France and often elsewhere in Europe, ECD is measured using a "naked-eye" procedure under a light microscope. To measure objectively the reliability of ECD determination in France, we developed four test corneas with a known ECD.
METHODS: The test corneas consisted of 1 mm2 of human corneal endothelium with stained cell borders. The 64 technicians of the 21 French eye banks counted according to the protocol applied in their respective centers.
RESULTS: More than half of the 256 counts (152, 59%) deviated by more than 10% from actual ECD. Of the counts, 85 (33%) were over-estimated, and 67 (26%) were under-estimated. Deviation ranged between 42% under-estimation and 82% over-estimation. Eight banks (38%) constantly over-estimated, and nine (43%) under-estimated ECD. Half of the inter-technician gaps within an eye bank were more than 10%, with a maximum of 51%.
CONCLUSIONS: This audit highlights the unacceptable lack of reliability of manual ECD assessment in French eye banks. This surely indicates the delivery of poor quality corneas for graft in certain centers and wastage in others. We urgently advocate normalization of French counting methods. This may require upgrading to a computer-aided method.

Entities:  

Mesh:

Year:  2004        PMID: 15548966     DOI: 10.1097/01.tp.0000130970.27013.b9

Source DB:  PubMed          Journal:  Transplantation        ISSN: 0041-1337            Impact factor:   4.939


  4 in total

1.  A new system for the automatic estimation of endothelial cell density in donor corneas.

Authors:  A Ruggeri; E Grisan; J Jaroszewski
Journal:  Br J Ophthalmol       Date:  2005-03       Impact factor: 4.638

2.  Evaluation of repeatability for the automatic estimation of endothelial cell density in donor corneas.

Authors:  Alfredo Ruggeri; Enrico Grisan; Jan Schroeter
Journal:  Br J Ophthalmol       Date:  2007-04-12       Impact factor: 4.638

3.  Preservation of Human Cornea.

Authors:  W John Armitage
Journal:  Transfus Med Hemother       Date:  2011-03-16       Impact factor: 3.747

4.  Specular microscopy ancillary study methods for donor endothelial cell density determination of Cornea Donor Study images.

Authors:  Beth Ann Benetz; Robin L Gal; Katrina J Ruedy; Carmella Rice; Roy W Beck; Andrea D Kalajian; Jonathan H Lass
Journal:  Curr Eye Res       Date:  2006-04       Impact factor: 2.424

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.