Literature DB >> 15546291

Drug-eluting bioabsorbable magnesium stent.

Carlo Di Mario1, Huw Griffiths, Omer Goktekin, Nicolas Peeters, Jan Verbist, Marc Bosiers, Koen Deloose, Bernhard Heublein, Roland Rohde, Victor Kasese, Charles Ilsley, Raimund Erbel.   

Abstract

Current stent technology is based on the use of permanent implants that remain life long in the vessel wall, far beyond the time required for the prosthesis to accomplish its main goals of sealing dissection and preventing wall recoil. With the possibility to implant long vessel segments using antiproliferative drugs to prevent restenosis, the practice of transforming the coronary vessels into stiff tubes with a full metal jacket covering all side branches and being unable to adjust to the long-term wall changes, including wall remodeling with lumen ectasia becomes a serious concern. In this article, we describe the first biodegradable stent based on a magnesium alloy that allows controlled corrosion with release to the vessel wall and the blood stream of a natural body component such as magnesium with beneficial antithrombotic, antiarrhythmic, and antiproliferative properties. We also discuss the animal experiments and the initial clinical applications in 20 patients with implants below the knee, with final results soon to be released, and the plans for the first coronary study. The results of these last two studies will indicate whether the absence of a permanent implant and the antiproliferative properties shown in animals are sufficient to prevent the restenotic process in humans or whether the prosthesis must be modified by adding the biodegradable coating with conventional antiproliferative drugs.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15546291     DOI: 10.1111/j.1540-8183.2004.04081.x

Source DB:  PubMed          Journal:  J Interv Cardiol        ISSN: 0896-4327            Impact factor:   2.279


  51 in total

1.  Endothelial responses of magnesium and other alloying elements in magnesium-based stent materials.

Authors:  Nan Zhao; Donghui Zhu
Journal:  Metallomics       Date:  2014-11-03       Impact factor: 4.526

2.  Drug-eluting stents.

Authors:  Xiaodong Ma; Tim Wu; Michael P Robich; Xingwei Wang; Hao Wu; Bryan Buchholz; Stephen McCarthy
Journal:  Int J Clin Exp Med       Date:  2010-07-15

Review 3.  The future of drug eluting stents.

Authors:  R R Anis; K R Karsch
Journal:  Heart       Date:  2005-10-10       Impact factor: 5.994

Review 4.  [Stenting of the SFA--indications, techniques, results].

Authors:  J Rieger; M Treitl; M Reiser; V Ruppert
Journal:  Radiologe       Date:  2006-11       Impact factor: 0.635

5.  Microstructure and corrosion properties of as sub-rapid solidification Mg-Zn-Y-Nd alloy in dynamic simulated body fluid for vascular stent application.

Authors:  Jun Wang; Liguo Wang; Shaokang Guan; Shijie Zhu; Chenxing Ren; Shusen Hou
Journal:  J Mater Sci Mater Med       Date:  2010-03-30       Impact factor: 3.896

6.  Anticorrosion and cytocompatibility behavior of MAO/PLLA modified magnesium alloy WE42.

Authors:  Meiqing Guo; Lu Cao; Ping Lu; Yin Liu; Xinhua Xu
Journal:  J Mater Sci Mater Med       Date:  2011-06-01       Impact factor: 3.896

7.  Bio-Adaption between Magnesium Alloy Stent and the Blood Vessel: A Review.

Authors:  Jun Ma; Nan Zhao; Lexxus Betts; Donghui Zhu
Journal:  J Mater Sci Technol       Date:  2015-12-24       Impact factor: 8.067

8.  MgZnCa glasses without clinically observable hydrogen evolution for biodegradable implants.

Authors:  Bruno Zberg; Peter J Uggowitzer; Jörg F Löffler
Journal:  Nat Mater       Date:  2009-09-27       Impact factor: 43.841

9.  Structural characteristics and corrosion behavior of biodegradable Mg-Zn, Mg-Zn-Gd alloys.

Authors:  J Kubásek; D Vojtěch
Journal:  J Mater Sci Mater Med       Date:  2013-03-26       Impact factor: 3.896

10.  AMS INSIGHT--absorbable metal stent implantation for treatment of below-the-knee critical limb ischemia: 6-month analysis.

Authors:  Marc Bosiers; Patrick Peeters; Olivier D'Archambeau; Jeroen Hendriks; Ernst Pilger; Christoph Düber; Thomas Zeller; Andreas Gussmann; Paul N M Lohle; Erich Minar; Dierk Scheinert; Klaus Hausegger; Karl-Ludwig Schulte; Jürgen Verbist; Koen Deloose; J Lammer
Journal:  Cardiovasc Intervent Radiol       Date:  2008-12-18       Impact factor: 2.740

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.