Comparative study between patellar-tendon-bearing and pressure cast prosthetic sockets.

James Cho Hong Goh1, Peter Vee Sin Lee, Sook Yee Chong.   

Abstract

This study compared the pressure distribution at the residual limb and socket interface in amputees wearing a pressure cast (PCast) socket system with amputees wearing the patellar-tendon-bearing (PTB) socket. The PCast system requires the subject to place his or her residual limb in a pressure chamber. Pressure is applied to the residual limb while the subject adopts a normal standing position. Four unilateral male amputees were fitted with both PTB and PCast sockets. Using a specially built strain-gauge-type pressure transducer, we recorded residual limb and socket pressure profiles for each subject wearing the two types of sockets during standing and walking. While some subjects exhibited similar anterior-posterior or medial-lateral pressure profiles for both prostheses, especially during push-off, other subjects exhibited high pressure distally in the PCast socket or higher-pressure concentration at the proximal region in the PTB socket.

Mesh:

Year:  2004        PMID: 15543467     DOI: 10.1682/jrrd.2004.03.0491

Source DB:  PubMed          Journal:  J Rehabil Res Dev        ISSN: 0748-7711


  5 in total

1.  Comparative study between Dermo, Pelite, and Seal-In X5 liners: effect on patient's satisfaction and perceived problems.

Authors:  Sadeeq Ali; Noor Azuan Abu Osman; Nooranida Arifin; Hossein Gholizadeh; Nasrul Anwar Abd Razak; Wan Abu Bakar Wan Abas
Journal:  ScientificWorldJournal       Date:  2014-08-11

2.  Predictive prosthetic socket design: part 2-generating person-specific candidate designs using multi-objective genetic algorithms.

Authors:  J W Steer; P A Grudniewski; M Browne; P R Worsley; A J Sobey; A S Dickinson
Journal:  Biomech Model Mechanobiol       Date:  2019-11-18

3.  Assessment of lower limb peripheral nerves with ultrasound in patients with traumatic amputation.

Authors:  İlkay Karabay; Yasin Demir; Özlem Köroğlu; Sefa Gümrük Aslan; Koray Aydemir; Eda Gürçay
Journal:  Turk J Phys Med Rehabil       Date:  2021-09-01

Review 4.  The use of fiber Bragg grating sensors in biomechanics and rehabilitation applications: the state-of-the-art and ongoing research topics.

Authors:  Ebrahim Al-Fakih; Noor Azuan Abu Osman; Faisal Rafiq Mahamd Adikan
Journal:  Sensors (Basel)       Date:  2012-09-25       Impact factor: 3.576

Review 5.  Techniques for Interface Stress Measurements within Prosthetic Sockets of Transtibial Amputees: A Review of the Past 50 Years of Research.

Authors:  Ebrahim A Al-Fakih; Noor Azuan Abu Osman; Faisal Rafiq Mahmad Adikan
Journal:  Sensors (Basel)       Date:  2016-07-20       Impact factor: 3.576