Effects of intraaortic balloon position on renal artery blood flow.

M T Swartz1, T Sakamoto, H Arai, J E Reedy, L Salenas, T Yuda, J W Standeven, D G Pennington.   

Abstract

Debate continues over what happens to renal blood flow when intraaortic balloons are adjacent to the renal arteries. Fourteen dogs were prepared by implanting instruments to measure heart rate; right atrial, pulmonary arterial, carotid arterial, and femoral arterial pressures; cardiac index; mixed venous oxygen saturation; urine output; and left and right renal blood flows. A 12-mL intraaortic balloon was inserted through the left (n = 9) or right (n = 5) femoral artery. The position of the balloon was randomized so that it was initially placed in either the control (thoracic) or renal position (at the level of the renal arteries). Intraaortic balloon pumping was performed for 4 hours in each position. In 8 dogs, at least one of the renal arteries had partial occlusion, 23% to 98% decrease in flow (mean decrease, 66%), while the intraaortic balloon was in the renal position. An intraaortic balloon in the renal position results in lower renal blood flow as well as a high risk (57%) of selective renal artery occlusion. Decreased renal blood flow is not apparent using conventional monitoring, as hemodynamics do not change.

Entities:  

Mesh:

Year:  1992        PMID: 1554268     DOI: 10.1016/0003-4975(92)90318-x

Source DB:  PubMed          Journal:  Ann Thorac Surg        ISSN: 0003-4975            Impact factor:   4.330


  4 in total

1.  Peripheral organ perfusion augmentation during left ventricular failure. A controlled bovine comparison between the intraaortic balloon pump and the Hemopump.

Authors:  R T Baldwin; B Radovancević; J L Conger; R Matsuwaka; J M Duncan; W K Vaughn; R K Wampler; O H Frazier
Journal:  Tex Heart Inst J       Date:  1993

2.  A statistical model that predicts the length from the left subclavian artery to the celiac axis; towards accurate intra aortic balloon sizing.

Authors:  Haralabos Parissis; Alan Soo; Michalis Leotsinidis; Dimitrios Dougenis
Journal:  J Cardiothorac Surg       Date:  2011-08-09       Impact factor: 1.637

Review 3.  Intra aortic balloon pump: literature review of risk factors related to complications of the intraaortic balloon pump.

Authors:  Haralabos Parissis; Alan Soo; Bassel Al-Alao
Journal:  J Cardiothorac Surg       Date:  2011-11-02       Impact factor: 1.637

Review 4.  IABP: history-evolution-pathophysiology-indications: what we need to know.

Authors:  H Parissis; V Graham; S Lampridis; M Lau; G Hooks; P C Mhandu
Journal:  J Cardiothorac Surg       Date:  2016-08-04       Impact factor: 1.637

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.