Literature DB >> 15535054

Elastic behavior of porcine coronary artery tissue under uniaxial and equibiaxial tension.

C Lally1, A J Reid, P J Prendergast.   

Abstract

The aim of this study was to characterize the nonlinear anisotropic elastic behavior of healthy porcine coronary arteries under uniaxial and equibiaxial tension. Porcine coronary tissue was chosen for its availability and similarity to human arterial tissue. A biaxial test device previously used to test human femoral arterial tissue samples (Prendergast, P. J., C. Lally, S. Daly, A. J. Reid, T. C. Lee, D. Quinn, and F. Dolan. ASME J. Biomech. Eng., Vol. 125, pp. 692-699, 2003) was further developed to test porcine coronary tissue specimens. The device applies an equal force to the four sides of a square specimen and therefore creates a biaxial stretch that demonstrates the anisotropy of arterial tissue. The nonlinear elastic behavior was marked in both uniaxial and biaxial tests. The tissue demonstrated higher stiffness in the circumferential direction in four out of eight cases subjected to biaxial tension. Even though anisotropy is demonstrated it is proposed that an isotropic hyperelastic model may adequately represent the properties of an artery, provided that an axial stretch is applied to the vessel to simulate the in vivo longitudinal tethering on the vessel. Isotropic hyperelastic models based on the Mooney-Rivlin constitutive equation were derived from the test data by averaging the longitudinal and circumferential equibiaxial data. Three different hyperelastic models were established to represent the test specimens that exhibited a high stiffness, an average stiffness, and a low stiffness response; these three models allow the analyst to account for the variability in the arterial tissue mechanical properties. These models, which take account of the nonlinear elastic behavior of coronary tissue, may be implemented in finite element models and used to carry out preclinical tests of intravascular devices. The errors associated with the hyperelastic models when fitting to both the uniaxial and equibiaxial data for the low stiffness, average stiffness, and high stiffness models were found to be 0.836, 5.206, and 2.980, respectively.

Entities:  

Mesh:

Year:  2004        PMID: 15535054     DOI: 10.1114/b:abme.0000042224.23927.ce

Source DB:  PubMed          Journal:  Ann Biomed Eng        ISSN: 0090-6964            Impact factor:   3.934


  27 in total

1.  Obstruction-induced pulmonary vascular remodeling.

Authors:  Ming-Jay Chow; Yu Zou; Huamei He; Francis X McGowan; David Zurakowski; Yanhang Zhang
Journal:  J Biomech Eng       Date:  2011-11       Impact factor: 2.097

2.  Congruence of imaging estimators and mechanical measurements of viscoelastic properties of soft tissues.

Authors:  Man Zhang; Benjamin Castaneda; Zhe Wu; Priya Nigwekar; Jean V Joseph; Deborah J Rubens; Kevin J Parker
Journal:  Ultrasound Med Biol       Date:  2007-07-02       Impact factor: 2.998

3.  Quasi-linear viscoelastic modeling of arterial wall for surgical simulation.

Authors:  Tao Yang; Chee Kong Chui; Rui Qi Yu; Jing Qin; Stephen K Y Chang
Journal:  Int J Comput Assist Radiol Surg       Date:  2011-04-13       Impact factor: 2.924

Review 4.  The time has come to extend the expiration limit of cryopreserved allograft heart valves.

Authors:  Jan Burkert; Petra Kochová; Zbyněk Tonar; Robert Cimrman; Tereza Blassová; Ramadan Jashari; Radovan Fiala; Jaroslav Špatenka
Journal:  Cell Tissue Bank       Date:  2020-06-24       Impact factor: 1.522

5.  Biomechanical analysis of the splenic avulsion mechanism.

Authors:  Omar Chebil; Michel Behr; Florent Auriault; Pierre-Jean Arnoux
Journal:  Med Biol Eng Comput       Date:  2014-06-19       Impact factor: 2.602

6.  A nonlinear finite element simulation of balloon expandable stent for assessment of plaque vulnerability inside a stenotic artery.

Authors:  Alireza Karimi; Mahdi Navidbakhsh; Hiroshi Yamada; Reza Razaghi
Journal:  Med Biol Eng Comput       Date:  2014-06-03       Impact factor: 2.602

7.  Twist buckling of veins under torsional loading.

Authors:  Justin R Garcia; Arnav Sanyal; Fatemeh Fatemifar; Mohammad Mottahedi; Hai-Chao Han
Journal:  J Biomech       Date:  2017-05-05       Impact factor: 2.712

8.  In silico assessment of the effects of material on stent deployment.

Authors:  Georgia S Karanasiou; Nikolaos S Tachos; Antonios Sakellarios; Lampros K Michalis; Claire Conway; Elazer R Edelman; Dimitrios I Fotiadis
Journal:  Proc IEEE Int Symp Bioinformatics Bioeng       Date:  2018-01-11

9.  Motion Artifact Reduction in Ultrasound Based Thermal Strain Imaging of Atherosclerotic Plaques Using Time Series Analysis.

Authors:  Debaditya Dutta; Ahmed M Mahmoud; Steven A Leers; Kang Kim
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2013-08-02       Impact factor: 2.725

10.  Vascular Response to Experimental Stent Malapposition and Under-Expansion.

Authors:  Caroline C O'Brien; Augusto C Lopes; Kumaran Kolandaivelu; Mie Kunio; Jonathan Brown; Vijaya B Kolachalama; Claire Conway; Lynn Bailey; Peter Markham; Marco Costa; James Ware; Elazer R Edelman
Journal:  Ann Biomed Eng       Date:  2016-01-05       Impact factor: 3.934

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.