Errors and misconceptions in ECG measurement used for the detection of drug induced QT interval prolongation.

Marek Malik1.   

Abstract

Drug-induced changes in cardiac repolarisation receive substantial attention by regulatory agencies. Since there are presently no established accurate possibilities of testing the propensity to torsade induction during clinical drug development, the regulators require drug-related QT interval changes to be thoroughly investigated with almost all new pharmacological agents. Small QT interval changes are easy to miss and the regulators therefore expect the relevant studies to be very precise. Such a precision is not easy to achieve and different strategies have been proposed. The purpose of this article is to review the most frequent misconceptions and errors in the electrocardiogram handling and measurements related to the detection to drug-induced QT interval changes. Specifically, the article discusses (a) the possibilities of automatic measurement by standard electrocardiographic equipment, (b) the danger of casual measurement by central laboratories handling the electrocardiograms, (c) the selection of recording leads for QT interval measurement, and (d) the problem of the so-called heart rate hysteresis of the QT interval adaptation. Suggestions are made for drug developers of what study design and quality control aspects are needed to avoid the most frequent imprecisions.

Entities:  

Mesh:

Year:  2004        PMID: 15534789     DOI: 10.1016/j.jelectrocard.2004.08.005

Source DB:  PubMed          Journal:  J Electrocardiol        ISSN: 0022-0736            Impact factor:   1.438


  25 in total

1.  Pharmacokinetic-pharmacodynamic modelling of QT interval prolongation following citalopram overdoses.

Authors:  Lena E Friberg; Geoffrey K Isbister; Stephen B Duffull
Journal:  Br J Clin Pharmacol       Date:  2006-02       Impact factor: 4.335

2.  Identifying QT prolongation from ECG impressions using a general-purpose Natural Language Processor.

Authors:  Joshua C Denny; Randolph A Miller; Lemuel Russell Waitman; Mark A Arrieta; Joshua F Peterson
Journal:  Int J Med Inform       Date:  2008-10-19       Impact factor: 4.046

Review 3.  Thorough QT Studies: Questions and Quandaries.

Authors:  Marek Malik; Christine E Garnett; Joanne Zhang
Journal:  Drug Saf       Date:  2010-01-01       Impact factor: 5.606

Review 4.  Assessing QT interval prolongation and its associated risks with antipsychotics.

Authors:  Jimmi Nielsen; Claus Graff; Jørgen K Kanters; Egon Toft; David Taylor; Jonathan M Meyer
Journal:  CNS Drugs       Date:  2011-06-01       Impact factor: 5.749

5.  Does the prulifloxacin ECG study prove cardiac safety of the drug?

Authors:  Marek Malik
Journal:  Clin Drug Investig       Date:  2010       Impact factor: 2.859

6.  Baseline correction in parallel thorough QT studies.

Authors:  Joanne Zhang; Qianyu Dang; Marek Malik
Journal:  Drug Saf       Date:  2013-06       Impact factor: 5.606

7.  Predictive Power of f99 Repolarization Index for the Occurrence of Ventricular Arrhythmias.

Authors:  Corrado Giuliani; Cees A Swenne; Sumche Man; Angela Agostinelli; Sandro Fioretti; Francesco Di Nardo; Laura Burattini
Journal:  Ann Noninvasive Electrocardiol       Date:  2015-11-25       Impact factor: 1.468

8.  Short QT in a cohort of 1.7 million persons: prevalence, correlates, and prognosis.

Authors:  Carlos Iribarren; Alfred D Round; Jonathan A Peng; Meng Lu; Arthur L Klatsky; Jonathan G Zaroff; Taylor J Holve; Amit Prasad; Paul Stang
Journal:  Ann Noninvasive Electrocardiol       Date:  2014-05-14       Impact factor: 1.468

9.  Cardiac electrical activity in a genomically "humanized" chromogranin a monogenic mouse model with hyperadrenergic hypertension.

Authors:  Nagendu B Dev; Saiful A Mir; Jiaur R Gayen; Jawed A Siddiqui; Maja Mustapic; Sucheta M Vaingankar
Journal:  J Cardiovasc Transl Res       Date:  2014-05-13       Impact factor: 4.132

10.  The measurement of the QT and QTc on the neonatal and infant electrocardiogram: a comprehensive reliability assessment.

Authors:  Robert M Gow; Benjamin Ewald; Lillian Lai; Letizia Gardin; Jane Lougheed
Journal:  Ann Noninvasive Electrocardiol       Date:  2009-04       Impact factor: 1.468