Literature DB >> 15534552

450 closed fractures of the distal third of the tibia treated with a functional brace.

Augusto Sarmiento1, Loren L Latta.   

Abstract

Four hundred fifty closed fractures of the distal third of the tibial diaphysis, treated with a functional brace, are the subject of this study. Four (0.9%) of the fractures resulted in nonunion. The average healing time was 16.6 +/- 5.6 weeks, with a range from 10-40 weeks. The average final shortening was 5.1 +/- 4.8 mm with a range from 0-25 mm. Four hundred twenty four (94.2%) fractures healed with < 12 mm shortening. Initial shortening at the time of injury essentially was unchanged, from 4.4 +/- 4.5 mm to 4.4 +/- 3.9 mm final shortening. Axially unstable closed tibial fractures do not shorten beyond the initial shortening. Four-hundred five fractures (90.0%) healed with less than 8 degrees angular deformity in either the frontal or sagittal planes, and 302 (67.1%) healed with less than 5 degrees deformity in any plane. Overall, 391 fractures (87%) healed with shortening less than 12 mm and angulation in any plane less than 8 degrees . These degrees of angular deformity and shortening seem to compare favorably with those reported by other investigators using intramedullary nails. It seems that functional bracing is an effective method of treatment of a selected group of tibial fractures.

Entities:  

Mesh:

Year:  2004        PMID: 15534552     DOI: 10.1097/01.blo.0000137550.68318.f8

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  13 in total

1.  Intramedullary fixation of tibial shaft fractures: a comparison of the unlocked and interlocked nail.

Authors:  Yih-Shiunn Lee; Ting-Ying Lo; Hui-Ling Huang
Journal:  Int Orthop       Date:  2007-01-06       Impact factor: 3.075

Review 2.  Plate fixation versus intramedullary nailing for displaced extra-articular distal tibia fractures: a system review.

Authors:  Bo Li; Yuehua Yang; Lei-Sheng Jiang
Journal:  Eur J Orthop Surg Traumatol       Date:  2013-11-20

3.  Management of fractures of the distal third tibia by minimally invasive plate osteosynthesis - A prospective series of 50 patients.

Authors:  Siddhartha Venkata Paluvadi; Hitesh Lal; Deepak Mittal; Kandarp Vidyarthi
Journal:  J Clin Orthop Trauma       Date:  2014-08-31

4.  Treatment of distal tibial shaft fractures by three different surgical methods: a randomized, prospective study.

Authors:  Yongchuan Li; Xi Jiang; Qinghe Guo; Lei Zhu; Tianwen Ye; Aimin Chen
Journal:  Int Orthop       Date:  2014-02-19       Impact factor: 3.075

5.  Minimally Invasive Plate Osteosynthesis with Locking Plates for Distal Tibia Fractures.

Authors:  Ajeet Dhakar; Rajendra Annappa; Mahesh Gupta; Hemeshwar Harshwardhan; Prem Kotian; Pooja K Suresh
Journal:  J Clin Diagn Res       Date:  2016-03-01

6.  Minimally invasive locked plating of distal tibia fractures is safe and effective.

Authors:  Mario Ronga; Umile Giuseppe Longo; Nicola Maffulli
Journal:  Clin Orthop Relat Res       Date:  2009-07-30       Impact factor: 4.176

7.  Fractures of the middle third of the tibia treated with a functional brace.

Authors:  Augusto Sarmiento; Loren L Latta
Journal:  Clin Orthop Relat Res       Date:  2008-08-22       Impact factor: 4.176

8.  Novel management of distal tibial and fibular fractures with Acumed fibular nail and minimally invasive plating osteosynthesis technique: A case report.

Authors:  Tie-Jun Wang; Wei-Na Ju; Bao-Chang Qi
Journal:  Medicine (Baltimore)       Date:  2017-03       Impact factor: 1.889

9.  Some Historical Treatments should not be Forgotten: A Review of Cast Wedging and A Trick to Normalize Non-Standardized Digital X-rays.

Authors:  Nathan A Jacobson; Christopher L Lee
Journal:  J Orthop Case Rep       Date:  2014 Apr-Jun

10.  Minimally Invasive Plate Osteosynthesis (MIPO) for Proximal and Distal Fractures of The Tibia: A Biological Approach.

Authors:  P Gupta; A Tiwari; A Thora; J K Gandhi; V P Jog
Journal:  Malays Orthop J       Date:  2016-03
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.