Literature DB >> 15531304

Central corneal thickness and measured IOP response to topical ocular hypotensive medication in the Ocular Hypertension Treatment Study.

James D Brandt1, Julia A Beiser, Mae O Gordon, Michael A Kass.   

Abstract

PURPOSE: To determine whether central corneal thickness (CCT) correlates with measured intraocular pressure (IOP) response to topical ocular hypotensive medication in the Ocular Hypertension Treatment Study (OHTS).
DESIGN: Prospective randomized clinical trial.
METHODS: Intraocular pressure measurements were performed by Goldmann applanation tonometry. Central corneal thickness was measured by ultrasonic pachymetry. The following indicators of IOP response to topical ocular hypotensive medication were examined: (1) IOP after an initial four- to six-week one-eyed therapeutic trial of a nonselective beta-blocker (N = 549) or a prostaglandin analog (N = 201); (2) the mean IOP response during 12 to 60 months of follow-up among medication participants (N = 689); (3) the percentage of follow-up visits at which both eyes met the treatment goal; (4). the total number of different medications prescribed to reach treatment goal; and (5) the total number of different medications prescribed multiplied by the number of months each medication was prescribed.
RESULTS: Central corneal thickness was inversely related to the IOP response after the initial one-eyed therapeutic trial and during 12 to 60 months of follow-up (P < .05). Mean CCT was not correlated with the number of different medications prescribed during follow-up, the total medication-months, or the percentage of visits at which IOP target was met.
CONCLUSIONS: Individuals with thicker corneas had smaller measured IOP responses to ocular hypotensive medication than those with normal or thin corneas. We believe that CCT measurements may be useful in patient management and in interpreting clinical trials of ocular hypotensive medication.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15531304     DOI: 10.1016/j.ajo.2004.07.036

Source DB:  PubMed          Journal:  Am J Ophthalmol        ISSN: 0002-9394            Impact factor:   5.258


  21 in total

1.  Optical coherence tomography of the Ex-PRESS miniature glaucoma implant.

Authors:  F D Verbraak; D M de Bruin; M Sulak; L A M S de Jong; M Aalders; D J Faber; T G van Leeuwen
Journal:  Lasers Med Sci       Date:  2005-04-28       Impact factor: 3.161

Review 2.  [The risk of glaucoma and corneal thickness].

Authors:  A G Böhm
Journal:  Ophthalmologe       Date:  2005-09       Impact factor: 1.059

Review 3.  The thick and thin of the central corneal thickness in glaucoma.

Authors:  Graham W Belovay; Ivan Goldberg
Journal:  Eye (Lond)       Date:  2018-02-15       Impact factor: 3.775

4.  The biomechanical properties of the cornea in patients with systemic lupus erythematosus.

Authors:  A T Yazici; N Kara; K Yüksel; H Altinkaynak; O Baz; E Bozkurt; A Demirok
Journal:  Eye (Lond)       Date:  2011-05-06       Impact factor: 3.775

5.  Corneal pachymetry mapping with high-speed optical coherence tomography.

Authors:  Yan Li; Raj Shekhar; David Huang
Journal:  Ophthalmology       Date:  2006-05       Impact factor: 12.079

6.  Clinical trials - more than an assessment of treatment effect: LXV Edward Jackson Memorial Lecture.

Authors:  Frederick L Ferris
Journal:  Am J Ophthalmol       Date:  2009-01       Impact factor: 5.258

7.  Effects of topical travoprost 0.004% on intraocular pressure and corneal biomechanical properties in an animal model.

Authors:  Gabriel Lazcano-Gomez; David Ancona-Lezama; Felix Gil-Carrasco; Jesus Jimenez-Roman
Journal:  Digit J Ophthalmol       Date:  2016-02-11

8.  Telemedicine for Glaucoma: Guidelines and Recommendations.

Authors:  Kenman Gan; Yao Liu; Brian Stagg; Siddarth Rathi; Louis R Pasquale; Karim Damji
Journal:  Telemed J E Health       Date:  2020-03-25       Impact factor: 3.536

9.  Practice Guidelines for Ocular Telehealth-Diabetic Retinopathy, Third Edition.

Authors:  Mark B Horton; Christopher J Brady; Jerry Cavallerano; Michael Abramoff; Gail Barker; Michael F Chiang; Charlene H Crockett; Seema Garg; Peter Karth; Yao Liu; Clark D Newman; Siddarth Rathi; Veeral Sheth; Paolo Silva; Kristen Stebbins; Ingrid Zimmer-Galler
Journal:  Telemed J E Health       Date:  2020-03-25       Impact factor: 3.536

10.  Frequency Doubling Technology vs Standard Automated Perimetry in Ocular Hypertensive Patients.

Authors:  Italo Giuffrè
Journal:  Open Ophthalmol J       Date:  2009-03-24
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.