Literature DB >> 15530250

Small-animal X-ray dose from micro-CT.

John M Boone1, Orlando Velazquez, Simon R Cherry.   

Abstract

The use of micro-CT in small animals has increased in recent years. Although the radiation levels used for micro-CT are generally not lethal to the animal, they are high enough where changes in the immune response and other biological pathways may alter the experimental outcomes. Therefore, it is important to understand what the doses are for a specific imaging procedure. Monte Carlo simulation was used to evaluate the radiation dose to small animals (5-40 mm in diameter) as a result of X-ray exposure. Both monoenergetic (6-100 keV) and polyenergetic (15-100 kVp) X-ray sources were simulated under typical mouse imaging geometries. X-ray spectral measurements were performed on a mouse imaging X-ray system using a commercially available X-ray spectrometer, and spectra from high-energy systems were used as well. For a typical X-ray system with 1.0 mm of added Al at 40 kVp, the dose coefficients (dose to mouse per air kerma at isocenter) were 0.80, 0.63, 0.52, and 0.44 mGy/mGy for mouse diameters of 10, 20, 30, and 40 mm, respectively. A number of tables and figures are provided for dose estimation over a range of mouse imaging geometries.

Entities:  

Mesh:

Year:  2004        PMID: 15530250     DOI: 10.1162/1535350042380326

Source DB:  PubMed          Journal:  Mol Imaging        ISSN: 1535-3508            Impact factor:   4.488


  52 in total

1.  Potential applications of flat-panel volumetric CT in morphologic and functional small animal imaging.

Authors:  Susanne Greschus; Fabian Kiessling; Matthias P Lichy; Jens Moll; Margareta M Mueller; Rajkumar Savai; Frank Rose; Clemens Ruppert; Andreas Günther; Marcus Luecke; Norbert E Fusenig; Wolfhard Semmler; Horst Traupe
Journal:  Neoplasia       Date:  2005-08       Impact factor: 5.715

2.  Monte carlo simulations of dose from microCT imaging procedures in a realistic mouse phantom.

Authors:  Richard Taschereau; Patrick L Chow; Arion F Chatziioannou
Journal:  Med Phys       Date:  2006-01       Impact factor: 4.071

Review 3.  PET/MRI hybrid imaging: devices and initial results.

Authors:  Bernd J Pichler; Martin S Judenhofer; Hans F Wehrl
Journal:  Eur Radiol       Date:  2008-03-21       Impact factor: 5.315

4.  Vascular Casting of Adult and Early Postnatal Mouse Lungs for Micro-CT Imaging.

Authors:  Russell H Knutsen; Leah M Gober; Joseph R Sukinik; Danielle R Donahue; Elise K Kronquist; Mark D Levin; Sean E McLean; Beth A Kozel
Journal:  J Vis Exp       Date:  2020-06-20       Impact factor: 1.355

5.  Microcomputed tomography colonography for polyp detection in an in vivo mouse tumor model.

Authors:  Perry J Pickhardt; Richard B Halberg; Andrew J Taylor; Ben Y Durkee; Jason Fine; Fred T Lee; Jamey P Weichert
Journal:  Proc Natl Acad Sci U S A       Date:  2005-02-22       Impact factor: 11.205

6.  Experimentally reducing corticosterone mitigates rapid captivity effects on behavior, but not body composition, in a wild bird.

Authors:  Christine R Lattin; Anita V Pechenenko; Richard E Carson
Journal:  Horm Behav       Date:  2017-01-05       Impact factor: 3.587

7.  Photon-counting computed tomography of lanthanide contrast agents with a high-flux 330-μm-pitch cadmium zinc telluride detector in a table-top system.

Authors:  Chelsea A S Dunning; Jericho O'Connell; Spencer M Robinson; Kevin J Murphy; Adriaan L Frencken; Frank C J M van Veggel; Kris Iniewski; Magdalena Bazalova-Carter
Journal:  J Med Imaging (Bellingham)       Date:  2020-06-15

8.  Development of a micro-computed tomography-based image-guided conformal radiotherapy system for small animals.

Authors:  Hu Zhou; Manuel Rodriguez; Fred van den Haak; Geoffrey Nelson; Rahil Jogani; Jiali Xu; Xinzhi Zhu; Yongjiang Xian; Phuoc T Tran; Dean W Felsher; Paul J Keall; Edward E Graves
Journal:  Int J Radiat Oncol Biol Phys       Date:  2010-04-13       Impact factor: 7.038

9.  Guidelines for the welfare and use of animals in cancer research.

Authors:  P Workman; E O Aboagye; F Balkwill; A Balmain; G Bruder; D J Chaplin; J A Double; J Everitt; D A H Farningham; M J Glennie; L R Kelland; V Robinson; I J Stratford; G M Tozer; S Watson; S R Wedge; S A Eccles
Journal:  Br J Cancer       Date:  2010-05-25       Impact factor: 7.640

10.  Small animal absorbed radiation dose from serial micro-computed tomography imaging.

Authors:  Stephanie K Carlson; Kelly L Classic; Claire E Bender; Stephen J Russell
Journal:  Mol Imaging Biol       Date:  2007 Mar-Apr       Impact factor: 3.488

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.