Literature DB >> 15527992

Magnetic resonance imaging of the knee with ultrashort TE pulse sequences.

Peter D Gatehouse1, Rhidian W Thomas, Matthew D Robson, Gavin Hamilton, Amy H Herlihy, Graeme M Bydder.   

Abstract

BACKGROUND: We wished to assess the feasibility of imaging the knee with ultrashort TE (UTE) pulse sequences. SUBJECTS AND METHODS: Five volunteers and 16 patients were studied with UTE (TE=0.08 ms) sequences including later echoes. Conventional fat-suppressed images and difference images were also produced by subtracting a later echo from the first. Gadodiamide enhancement was used.
RESULTS: High signal was obtained in tendons, ligaments, menisci and periosteum. Normal contrast enhancement was seen in these structures. Deep and superficial layers were seen in the articular cartilage. Cartilage defects were identified. The red zone could be differentiated from the white zone of the meniscus. Meniscal tears and degeneration were observed with low signal on subtraction images. Enhancement was seen within the anterior and posterior cruciate ligaments and associated scar tissue.
CONCLUSION: Ultrashort TE imaging provides new options to visualize anatomy, manipulate conspicuity, observe contrast enhancement and demonstrate disease of the knee.

Entities:  

Mesh:

Year:  2004        PMID: 15527992     DOI: 10.1016/j.mri.2004.08.018

Source DB:  PubMed          Journal:  Magn Reson Imaging        ISSN: 0730-725X            Impact factor:   2.546


  28 in total

1.  UTE T2∗ mapping detects sub-clinical meniscus degeneration.

Authors:  E J McWalter; G E Gold
Journal:  Osteoarthritis Cartilage       Date:  2012-03-08       Impact factor: 6.576

Review 2.  Magnetic resonance imaging of the knee: optimizing 3 Tesla imaging.

Authors:  Lauren Shapiro; Ernesto Staroswiecki; Garry Gold
Journal:  Semin Roentgenol       Date:  2010-10       Impact factor: 0.800

3.  Ultrashort TE evaluation of the osteochondral junction in vivo: a feasibility study.

Authors:  James W Mackay; Samantha B L Low; Gavin C Houston; Andoni P Toms
Journal:  Br J Radiol       Date:  2016-01-19       Impact factor: 3.039

Review 4.  MRI of the hip for the evaluation of femoroacetabular impingement; past, present, and future.

Authors:  Geoffrey M Riley; Emily J McWalter; Kathryn J Stevens; Marc R Safran; Riccardo Lattanzi; Garry E Gold
Journal:  J Magn Reson Imaging       Date:  2014-08-23       Impact factor: 4.813

5.  Ultrashort echo time MR imaging of osteochondral junction of the knee at 3 T: identification of anatomic structures contributing to signal intensity.

Authors:  Won C Bae; Jerry R Dwek; Richard Znamirowski; Sheronda M Statum; Juan C Hermida; Darryl D D'Lima; Robert L Sah; Jiang Du; Christine B Chung
Journal:  Radiology       Date:  2010-03       Impact factor: 11.105

6.  Using adiabatic inversion pulses for long-T2 suppression in ultrashort echo time (UTE) imaging.

Authors:  Peder E Z Larson; Steven M Conolly; John M Pauly; Dwight G Nishimura
Journal:  Magn Reson Med       Date:  2007-11       Impact factor: 4.668

7.  UTE MRI of the Osteochondral Junction.

Authors:  Won C Bae; Reni Biswas; Karen Chen; Eric Y Chang; Christine B Chung
Journal:  Curr Radiol Rep       Date:  2014-02-01

Review 8.  MR imaging of articular cartilage physiology.

Authors:  Jung-Ah Choi; Garry E Gold
Journal:  Magn Reson Imaging Clin N Am       Date:  2011-05       Impact factor: 2.266

9.  Quantitative 3D ultrashort time-to-echo (UTE) MRI and micro-CT (μCT) evaluation of the temporomandibular joint (TMJ) condylar morphology.

Authors:  Daniel Geiger; Won C Bae; Sheronda Statum; Jiang Du; Christine B Chung
Journal:  Skeletal Radiol       Date:  2013-10-04       Impact factor: 2.199

Review 10.  Sodium and T1rho MRI for molecular and diagnostic imaging of articular cartilage.

Authors:  Arijitt Borthakur; Eric Mellon; Sampreet Niyogi; Walter Witschey; J Bruce Kneeland; Ravinder Reddy
Journal:  NMR Biomed       Date:  2006-11       Impact factor: 4.044

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.