Literature DB >> 15523972

Advantages and disadvantages of the Zernike expansion for representing wave aberration of the normal and aberrated eye.

Stephen D Klyce1, Michael D Karon, Michael K Smolek.   

Abstract

PURPOSE: Zernike expansion has been selected for use in describing wavefront aberrations in the human eye. The advantages and limitations of this approach are assessed for eyes with varying degrees of aberration.
METHODS: Corneal topography examinations were taken with the Nidek OPD-Scan topographer/aberrometer. These higher data density corneal topography examinations were converted to height data and subsequently to wavefront representations. System noise was evaluated with a 2D frequency analysis of 43-D test balls. Both Zernike polynomials and 2D Fourier transforms were used to evaluate fidelity in the presentation of the point spread function. A display format for potential clinical use was developed based upon Zernike decomposition.
RESULTS: Systematic noise from the corneal topographer was found to be minimal and, when eliminated, produced small changes in the point spread function. Using Zernike decomposition up to the 30th order failed to preserve the higher frequency aberrations present in aberrated eyes. Use of a Zernike decomposition display with a fixed micron scale presented only clinically significant details of spherical aberration, coma, trefoil, irregular components above third order and total higher-order aberrations (above second order).
CONCLUSIONS: Zernike polynomials excel in extracting the low-order optical characteristics of visual optics. Zernikes accurately represent both low- and high-order aberrations in normal eyes where high-order aberrations are clinically insignificant. For eyes after corneal surgery or eyes with corneal pathology such as keratoconus that have significant higher-order aberrations, the Zernike method fails to capture all clinically significant higher-order aberrations.

Entities:  

Mesh:

Year:  2004        PMID: 15523972     DOI: 10.3928/1081-597X-20040901-25

Source DB:  PubMed          Journal:  J Refract Surg        ISSN: 1081-597X            Impact factor:   3.573


  13 in total

1.  Impact of Zernike-fit error on simulated high- and low-contrast acuity in keratoconus: implications for using Zernike-based corrections.

Authors:  Jason D Marsack; Konrad Pesudovs; Edwin J Sarver; Raymond A Applegate
Journal:  J Opt Soc Am A Opt Image Sci Vis       Date:  2006-04       Impact factor: 2.129

2.  Comparison of Zernike and Fourier wavefront reconstruction algorithms in representing corneal aberration of normal and abnormal eyes.

Authors:  Geunyoung Yoon; Seth Pantanelli; Scott MacRae
Journal:  J Refract Surg       Date:  2008-06       Impact factor: 3.573

3.  Statistical virtual eye model based on wavefront aberration.

Authors:  Jie-Mei Wang; Chun-Ling Liu; Yi-Ning Luo; Yi-Guang Liu; Bing-Jie Hu
Journal:  Int J Ophthalmol       Date:  2012-10-18       Impact factor: 1.779

4.  Three different aspheric treatment algorithms of laser-assisted sub-epithelial keratectomy in patients with high myopia.

Authors:  Ji Min Ahn; Bong Joon Choi; Eung Kweon Kim; Bradford Sgrignoli; Tae-im Kim
Journal:  Jpn J Ophthalmol       Date:  2012-12-07       Impact factor: 2.447

5.  Higher-order aberrations after wavefront-optimized photorefractive keratectomy and laser in situ keratomileusis.

Authors:  J Bradley Randleman; Claudia E Perez-Straziota; Michelle H Hu; Alfred J White; Evan S Loft; R Doyle Stulting
Journal:  J Cataract Refract Surg       Date:  2009-02       Impact factor: 3.351

6.  Geometrical custom modeling of human cornea in vivo and its use for the diagnosis of corneal ectasia.

Authors:  Francisco Cavas-Martínez; Daniel G Fernández-Pacheco; Ernesto De la Cruz-Sánchez; José Nieto Martínez; Francisco J Fernández Cañavate; Alfredo Vega-Estrada; Ana B Plaza-Puche; Jorge L Alió
Journal:  PLoS One       Date:  2014-10-17       Impact factor: 3.240

7.  Ocular higher-order aberrations changes after implantable collamer lens implantation for high myopic astigmatism.

Authors:  Seyed Javad Hashemian; Hosein Farrokhi; Alireza Foroutan; Mohammad Ebrahim Jafari; Seyed Mahyar Hashemian; Sayyed Amirpooya Alemzadeh; Mahsa Sadat Hashemian
Journal:  J Curr Ophthalmol       Date:  2017-11-10

8.  Analysis of four aberrometers for evaluating lower and higher order aberrations.

Authors:  Fabiano Cade; Andrea Cruzat; Eleftherios I Paschalis; Lilian Espírito Santo; Roberto Pineda
Journal:  PLoS One       Date:  2013-01-22       Impact factor: 3.240

9.  Evaluation of the effect of corneal collagen cross-linking for keratoconus on the ocular higher-order aberrations.

Authors:  Ahmed Abdel-Karim El-Massry; Amgad Mostafa Dowidar; Tamer Hamdy Massoud; Baher Guirguis Daoud Tadros
Journal:  Clin Ophthalmol       Date:  2017-08-09

10.  Study and characterization of morphogeometric parameters to assist diagnosis of keratoconus.

Authors:  Francisco Cavas-Martínez; Daniel G Fernández-Pacheco; Dolores Parras; Francisco J F Cañavate; Laurent Bataille; Jorge Alió
Journal:  Biomed Eng Online       Date:  2018-11-20       Impact factor: 2.819

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.