Literature DB >> 15519804

Reproducibility of organ position using voluntary breath-hold method with spirometer for extracranial stereotactic radiotherapy.

Tomoki Kimura1, Yutaka Hirokawa, Yuji Murakami, Masatsugu Tsujimura, Tateo Nakashima, Yoshimi Ohno, Masahiro Kenjo, Yuko Kaneyasu, Koichi Wadasaki, Katsuhide Ito.   

Abstract

PURPOSE: To evaluate in healthy volunteers the reproducibility of organ position using a voluntary breath-hold method with a spirometer and the feasibility of this method for extracranial stereotactic radiotherapy in a clinical setting. METHODS AND MATERIALS: For this study, 5 healthy volunteers were enrolled. After training sessions, they held their breath at the end-inspiration and the end-expiration phase under spirometer-based monitoring. Computed tomography (CT) scans were performed twice at each respiratory phase, with a 10-min interval, on 2 separate days. The total number of CT scans was four at each respiratory phase. After CT volume data were transferred to a three-dimensional treatment-planning system, digitally reconstructed radiographs (DRRs) were calculated for anterior-posterior and left-right beams. Verification was performed with DRRs relative to the diaphragm position, bony landmarks, and the isocenter in each healthy volunteer at each respiratory phase. To evaluate intrafraction reproducibility, we measured the distance between diaphragm position and bony landmarks. To evaluate interfraction reproducibility, we measured the distance between diaphragm position and the isocenter. Reproducibility and setup error were defined as the average value of the differences between each DRR with regard to the first DRR.
RESULTS: Intrafraction reproducibility of the caudal-cranial direction was 4.0 +/- 3.5 mm at the end-inspiration phase and 2.2 +/- 2.0 mm at the end-expiration phase. Interfraction reproducibility of the caudal-cranial direction was 5.1 +/- 4.8 mm at the end-inspiration phase and 2.1 +/- 1.8 mm at the end-expiration phase. The end-expiration phase was more stable than the end-inspiration phase.
CONCLUSIONS: The voluntary breath-hold method with a spirometer is feasible, with relatively good reproducibility. We are encouraged about the use of this technique clinically for extracranial stereotactic radiotherapy.

Mesh:

Year:  2004        PMID: 15519804     DOI: 10.1016/j.ijrobp.2004.07.718

Source DB:  PubMed          Journal:  Int J Radiat Oncol Biol Phys        ISSN: 0360-3016            Impact factor:   7.038


  15 in total

1.  Digital tomosynthesis for respiratory gated liver treatment: clinical feasibility for daily image guidance.

Authors:  Q Jackie Wu; Jeffrey Meyer; Jessica Fuller; Devon Godfrey; Zhiheng Wang; Junan Zhang; Fang-Fang Yin
Journal:  Int J Radiat Oncol Biol Phys       Date:  2010-06-18       Impact factor: 7.038

2.  Breath-hold monitoring and visual feedback for radiotherapy using a charge-coupled device camera and a head-mounted display: system development and feasibility.

Authors:  Tadamasa Yoshitake; Katsumasa Nakamura; Yoshiyuki Shioyama; Satoshi Nomoto; Saiji Ohga; Takashi Toba; Takehiro Shiinoki; Shigeo Anai; Hiromi Terashima; Junji Kishimoto; Hiroshi Honda
Journal:  Radiat Med       Date:  2008-01-31

Review 3.  Treatment of early stage non-small cell lung cancer: surgery or stereotactic ablative radiotherapy?

Authors:  Esengül Koçak Uzel; Ufuk Abacıoğlu
Journal:  Balkan Med J       Date:  2015-01-01       Impact factor: 2.021

4.  Reproducibility of diaphragm position assessed with a voluntary breath-holding device.

Authors:  Shigeyuki Takamatsu; Tsuyoshi Takanaka; Tomoyasu Kumano; Eiichi Mizuno; Satoshi Shibata; Shizuko Ohashi; Yuichi Kurata; Shinichi Ueda; Naoki Hori; Saori Shouji; Kimiya Noto; Hironori Kojima; Osamu Matsui
Journal:  Jpn J Radiol       Date:  2013-03-23       Impact factor: 2.374

5.  The impact of anatomic tumor location on inter-fraction tumor motion during lung stereotactic body radiation therapy (SBRT).

Authors:  Katelyn M Atkins; Yiyi Chen; David A Elliott; Tulsee S Doshi; Sanja Ognjenovic; Arjun S Vachhani; Monica Kishore; Steven L Primack; Martin Fuss; Mark E Deffebach; Charlotte Dai Kubicky; James A Tanyi
Journal:  J Radiosurg SBRT       Date:  2015

6.  Interfractional diaphragm changes during breath-holding in stereotactic body radiotherapy for liver cancer.

Authors:  Daisuke Kawahara; Shuichi Ozawa; Takeo Nakashima; Shintaro Tsuda; Yusuke Ochi; Takuro Okumura; Hirokazu Masuda; Kazunari Hioki; Tathsuhiko Suzuki; Yoshimi Ohno; Tomoki Kimura; Yuji Murakami; Yasushi Nagata
Journal:  Rep Pract Oncol Radiother       Date:  2018-02-10

7.  Geometric Reproducibility of Fiducial Markers and Efficacy of a Patient-Specific Margin Design Using Deep Inspiration Breath Hold for Stereotactic Body Radiation Therapy for Pancreatic Cancer.

Authors:  Sarah Han-Oh; Colin Hill; Ken Kang-Hsin Wang; Kai Ding; Jean L Wright; Sara Alcorn; Jeffrey Meyer; Joseph Herman; Amol Narang
Journal:  Adv Radiat Oncol       Date:  2021-01-22

8.  Incorporating breath holding and image guidance in the adjuvant gastric cancer radiotherapy: a dosimetric study.

Authors:  Weigang Hu; Jinsong Ye; Jiazhou Wang; Qing Xu; Zhen Zhang
Journal:  Radiat Oncol       Date:  2012-06-20       Impact factor: 3.481

9.  The Time Course of Dynamic Computed Tomographic Appearance of Radiation Injury to the Cirrhotic Liver Following Stereotactic Body Radiation Therapy for Hepatocellular Carcinoma.

Authors:  Tomoki Kimura; Shigeo Takahashi; Ippei Takahashi; Ikuno Nishibuchi; Yoshiko Doi; Masahiro Kenjo; Yuji Murakami; Yohji Honda; Hiroshi Aikata; Kazuaki Chayama; Yasushi Nagata
Journal:  PLoS One       Date:  2015-06-11       Impact factor: 3.240

10.  Magnitude of shift of tumor position as a function of moderated deep inspiration breath-hold: An analysis of pooled data of lung patients with active breath control in image-guided radiotherapy.

Authors:  K R Muralidhar; P Narayana Murthy; D Shankar Mahadev; K Subramanyam; G Sudarshan; A Krishnam Raju
Journal:  J Med Phys       Date:  2008-10
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.