Mechanics of the taper integrated screwed-in (TIS) abutments used in dental implants.

Dinçer Bozkaya1, Sinan Müftü.   

Abstract

The tapered implant-abutment interface is becoming more popular due to the mechanical reliability of retention it provides. Consequently, understanding the mechanical properties of the tapered interface with or without a screw at the bottom has been the subject of a considerable amount of studies involving experiments and finite element (FE) analysis. This paper focuses on the tapered implant-abutment interface with a screw integrated at the bottom of the abutment. The tightening and loosening torques are the main factors in determining the reliability and the stability of the attachment. Analytical formulas are developed to predict tightening and loosening torque values by combining the equations related to the tapered interface with screw mechanics equations. This enables the identification of the effects of the parameters such as friction, geometric properties of the screw, the taper angle, and the elastic properties of the materials on the mechanics of the system. In particular, a relation between the tightening torque and the screw pretension is identified. It was shown that the loosening torque is smaller than the tightening torque for typical values of the parameters. Most of the tightening load is carried by the tapered section of the abutment, and in certain combinations of the parameters the pretension in the screw may become zero. The calculations performed to determine the loosening torque as a percentage of tightening torque resulted in the range 85-137%, depending on the values of taper angle and the friction coefficient.

Mesh:

Substances:

Year:  2005        PMID: 15519343     DOI: 10.1016/j.jbiomech.2004.03.006

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  3 in total

1.  In vitro analysis of the microbiological sealing of tapered implants after mechanical cycling.

Authors:  Deceles Cristina Costa Alves; Paulo Sérgio Perri de Carvalho; Carlos Nelson Elias; Eduardo Vedovatto; Elizabeth Ferreira Martinez
Journal:  Clin Oral Investig       Date:  2016-02-20       Impact factor: 3.573

2.  Mechanical analysis of conventional and small diameter conical implant abutments.

Authors:  Izabela Cristina Maurício Moris; Adriana Cláudia Lapria Faria; Maria da Gloria Chiarello de Mattos; Ricardo Faria Ribeiro; Renata Cristina Silveira Rodrigues
Journal:  J Adv Prosthodont       Date:  2012-08-28       Impact factor: 1.904

3.  Mechanical Pull-Out Test of a New Hybrid Fixture-Abutment Connection: An In Vitro Study.

Authors:  Gianmaria D'Addazio; Bruna Sinjari; Lorenzo Arcuri; Beatrice Femminella; Giovanna Murmura; Manlio Santilli; Sergio Caputi
Journal:  Materials (Basel)       Date:  2021-03-22       Impact factor: 3.623

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.