Literature DB >> 15516347

Bispectral index and A-line AAI index as guidance for desflurane-remifentanil anaesthesia compared with a standard practice group: a multicentre study.

J Bruhn1, S Kreuer, P Bischoff, P Kessler, G N Schmidt, A Grzesiak, W Wilhelm.   

Abstract

BACKGROUND: This study was designed to investigate the impact of bispectral index (BIS) or A-line AAI index (based on middle-latency auditory evoked potential) monitoring on recovery times and drug consumption when compared with standard anaesthetic practice during desflurane-remifentanil anaesthesia.
METHODS: After having obtained approval from the institutional review board and written informed consent, 200 adult patients undergoing minor surgical procedures were randomized to receive a desflurane-remifentanil anaesthetic controlled either solely by clinical parameters or by BIS or AAI to the following target values: during maintenance of anaesthesia to a value of '50' (BIS) or '30' (AAI), 15 min before the end of surgery to '60' (BIS) or '45' (AAI). Recovery times and drug consumption were recorded by a blinded investigator.
RESULTS: Compared with standard practice, patients with BIS or AAI monitoring needed similar desflurane concentrations (standard practice 2.9 [0.5] vol%, BIS 3.3 [0.9] vol%, AAI 2.6 [0.5] vol%), and had similar recovery times (open eyes 5.6 [2.5] min, 5.9 [3.4] min, 5.0 [3.1] min; extubation 6.3 [2.4] min, 6.6 [3.5] min, 5.6 [3.0] min; stating name 7.3 [2.4] min, 7.6 [3.5] min, 7.3 [6.6] min).
CONCLUSIONS: Compared with standard anaesthetic practice BIS and AAI guided titration to the used target ranges did not result in a reduction of desflurane consumption or recovery times during minor surgery with use of remifentanil.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15516347     DOI: 10.1093/bja/aei013

Source DB:  PubMed          Journal:  Br J Anaesth        ISSN: 0007-0912            Impact factor:   9.166


  11 in total

Review 1.  [Measurement of the depth of anaesthesia].

Authors:  G N Schmidt; J Müller; P Bischoff
Journal:  Anaesthesist       Date:  2008-01       Impact factor: 1.041

2.  Response entropy is more reactive than bispectral index during laparoscopic gastric banding.

Authors:  James Feld; William E Hoffman
Journal:  J Clin Monit Comput       Date:  2006-07-04       Impact factor: 2.502

3.  The Effect of BIS Usage on Anaesthetic Agent Consumption, Haemodynamics and Recovery Time in Supratentorial Mass Surgery.

Authors:  İclal Karaca; Fatma Eren Akçıl; Özlem Korkmaz Dilmen; Güniz Meyancı Köksal; Yusuf Tunalı
Journal:  Turk J Anaesthesiol Reanim       Date:  2014-03-11

4.  Effects of A-line Autoregression Index (AAI) monitoring on recovery after sevoflurane anesthesia for bariatric surgery.

Authors:  Ulderico Freo; Michele Carron; Federico Innocente; Mirto Foletto; Donato Nitti; Carlo Ori
Journal:  Obes Surg       Date:  2011-07       Impact factor: 4.129

Review 5.  Bispectral index for improving anaesthetic delivery and postoperative recovery.

Authors:  Yodying Punjasawadwong; Aram Phongchiewboon; Nutchanart Bunchungmongkol
Journal:  Cochrane Database Syst Rev       Date:  2014-06-17

6.  The Effects of Bispectral Index and Neuromuscular Blockade Monitoring on the Depth of Anaesthesia and Recovery in Cardiac Patients Under Desflurane Anaesthesia.

Authors:  Ayşe Payas; Kenan Kaygusuz; Cevdet Düger; Ahmet Cemil İsbir; İclal Özdemir Kol; Sinan Gürsoy; Caner Mimaroğlu
Journal:  Turk J Anaesthesiol Reanim       Date:  2013-06-14

Review 7.  Anaesthetic interventions for prevention of awareness during surgery.

Authors:  Anthony G Messina; Michael Wang; Marshall J Ward; Chase C Wilker; Brett B Smith; Daniel P Vezina; Nathan Leon Pace
Journal:  Cochrane Database Syst Rev       Date:  2016-10-18

8.  Bispectral index for improving intraoperative awareness and early postoperative recovery in adults.

Authors:  Sharon R Lewis; Michael W Pritchard; Lizzy J Fawcett; Yodying Punjasawadwong
Journal:  Cochrane Database Syst Rev       Date:  2019-09-26

Review 9.  Processed electroencephalogram and evoked potential techniques for amelioration of postoperative delirium and cognitive dysfunction following non-cardiac and non-neurosurgical procedures in adults.

Authors:  Yodying Punjasawadwong; Waraporn Chau-In; Malinee Laopaiboon; Sirivimol Punjasawadwong; Pathomporn Pin-On
Journal:  Cochrane Database Syst Rev       Date:  2018-05-15

10.  Comparison of bispectral index and end-tidal anaesthetic concentration monitoring on recovery profile of desflurane in patients undergoing lumbar spine surgery.

Authors:  R Sudhakaran; Jeetinder K Makkar; Divya Jain; Jyotsna Wig; R Chabra
Journal:  Indian J Anaesth       Date:  2018-07
View more