Literature DB >> 15513483

Hip revision using the Exeter stem, impacted morselized allograft bone and cement: a consecutive 5-year radiostereometric and radiographic study in 15 hips.

Ewald Ornstein1, Herbert Franzén, Ragnar Johnsson, Magnus K Karlsson, Lars Linder, Martin Sundberg.   

Abstract

BACKGROUND: Impaction grafting in hip revision surgery is widely used but studies with mid- and long-term follow-up are scarce. PATIENTS, METHODS AND
RESULTS: A 5-year radiostereometric (RSA) follow-up of 15 hip revisions with the Exeter stem, morselized impacted allograft bone and cement revealed that 3 stems had not migrated between 2 and 5 years after revision, 11 stems had migrated to a minor degree in at least 1 direction, and 1 stem was loose according to RSA but without any radiographic signs of loosening or pain. The pain score was comparable to primary arthroplasties.
INTERPRETATION: From a 5-year perspective, first-time hip revisions for aseptic loosening with impacted morselized allograft bone and cement appear to yield good clinical results, although stem migration continues to a minor degree 2 years after revision.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15513483     DOI: 10.1080/00016470410001385

Source DB:  PubMed          Journal:  Acta Orthop Scand        ISSN: 0001-6470


  7 in total

1.  [Replacement of femoral hip prostheses].

Authors:  M Rudert; M Hoberg; P M Prodinger; R Gradinger; B M Holzapfel
Journal:  Chirurg       Date:  2010-04       Impact factor: 0.955

2.  Fixation and bone remodeling around a low stiffness stem in revision surgery.

Authors:  Johan Kärrholm; Reza Razaznejad
Journal:  Clin Orthop Relat Res       Date:  2008-01-10       Impact factor: 4.176

3.  Reduced femoral component subsidence with improved impaction grafting at revision hip arthroplasty.

Authors:  D W Howie; S A Callary; M A McGee; N C Russell; L B Solomon
Journal:  Clin Orthop Relat Res       Date:  2010-12       Impact factor: 4.176

4.  Impaction allograft with cement for the revision of the femoral component. A minimum 39-month follow-up study with the use of the Exeter stem in Asian hips.

Authors:  Soo-Jae Yim; Min-Young Kim; You-Sung Suh
Journal:  Int Orthop       Date:  2006-09-09       Impact factor: 3.075

5.  Differentially loaded radiostereometric analysis to monitor fracture stiffness: a feasibility study.

Authors:  Mellick J Chehade; Lucian B Solomon; Stuart A Callary; Sam H Benveniste; Anthony P Pohl; Donald W Howie
Journal:  Clin Orthop Relat Res       Date:  2009-01-29       Impact factor: 4.176

Review 6.  Adherence of hip and knee arthroplasty studies to RSA standardization guidelines. A systematic review.

Authors:  Rami Madanat; Tatu J Mäkinen; Hannu T Aro; Charles Bragdon; Henrik Malchau
Journal:  Acta Orthop       Date:  2014-06-23       Impact factor: 3.717

7.  Decreased migration with locally administered bisphosphonate in cemented cup revisions using impaction bone grafting technique.

Authors:  Vasileios Zampelis; Ola Belfrage; Magnus Tägil; Martin Sundberg; Gunnar Flivik
Journal:  Acta Orthop       Date:  2017-09-12       Impact factor: 3.717

  7 in total