Usability assessment of pacemaker programmers.

Christine C Chiu1, Kim J Vicente, Ilan Buffo-Sequeira, Robert M Hamilton, Brian W McCrindle.   

Abstract

There is a perception among clinicians of usability differences in the user interface of pacemaker programmers, but there is an absence of literature in this area. The purpose of this study was to describe usability differences in pacemaker programmers. Forty-two programmer users completed self-administered questionnaires and two usability experts independently performed heuristic evaluation to identify features that violated general usability principles. Programmers from seven manufacturers (coded A-G) were evaluated. There was a balanced representation of users: nurses (58%) versus technologists (40%) who are employed in community (50%) versus academic (45%) hospitals, novice versus expert users based on the median users' programming experience of 60 months (range 1-300 months). Significant differences between programmers were found in overall user satisfaction and ease of programmer use (P < 0.0001) in the display, controls, operation, and physical dimension of the programmers (P < 0.05). Heuristic evaluations showed frequent violations of usability principles in all programmers. Problematic areas include reliance on user recall, inconsistency in operation of critical controls, poor readability, and not anticipating user wants or action. Programmer interface designs do not consistently meet user needs or general usability principles. This impacts on the safe and effective use of programmers. Guidelines in programmer design should be established, particularly with respect to labeling, location, and operation of critical controls.

Mesh:

Year:  2004        PMID: 15511248     DOI: 10.1111/j.1540-8159.2004.00643.x

Source DB:  PubMed          Journal:  Pacing Clin Electrophysiol        ISSN: 0147-8389            Impact factor:   1.976


  3 in total

1.  Use of pacemaker programmers for disaster victim identification.

Authors:  Haruka Makinae; Norio Numata; Hirofumi Kitaoka; Masao Daimon; Taira Yamamoto; Atsushi Amano
Journal:  Forensic Sci Med Pathol       Date:  2013-04-17       Impact factor: 2.007

2.  [Efficiency potential in the pacemaker/implantable cardioverter defibrillator outpatient clinic].

Authors:  A Bauer; J Bauer; M Bauer; K Kelemen; F Voss; J Senges-Becker; S Weretka; H A Katus; R Becker
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2006-03

3.  A Human-Centered Design Methodology to Enhance the Usability, Human Factors, and User Experience of Connected Health Systems: A Three-Phase Methodology.

Authors:  Richard Harte; Liam Glynn; Alejandro Rodríguez-Molinero; Paul Ma Baker; Thomas Scharf; Leo R Quinlan; Gearóid ÓLaighin
Journal:  JMIR Hum Factors       Date:  2017-03-16
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.