Literature DB >> 15510854

Physical properties of different composites.

Mustafa Ersoy1, Arzu Civelek, Estelle L'Hotelier, Esra Can Say, Mubin Soyman.   

Abstract

The purpose of this study was to determine the flexural strength (FS), flexural modulus (FM), depth of cure (DC), polymerization shrinkage (PS), and microhardness (VH) of the following composites: Two packable composites--Filtek P-60 and Solitaire 2; One ion-releasing composite--riston AT; and Two hybrid composites--Charisma and Filtek Z-250. Data of the different tests conducted were obtained as follows: FS and FM data were determined with a universal-testing machine; Polymerization shrinkage was determined using the apparatus of Watts and Cash; Depth of cure was measured with a micrometer (Mitotuyo, UK); and Microhardness was measured with a Shimadzu Microhardness tester (500 g, 15 seconds). All data of the different tests were statistically analyzed by one-way variance analysis (ANOVA), which yielded the following results: Filtek Z-250 showed the statistically highest flexural strength and modulus values. Solitaire 2 exhibited the highest shrinkage, while the volumetric shrinkage results of Filtek Z-250 and Filtek P-60 ranked the lowest. For depth of cure, there were no statistically significant differences among all materials tested (p<0.05). Microhardness results revealed the following tendency: Filtek Z-250 = Filtek P-60 > Ariston AT = Solitaire 2 = Charisma.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15510854     DOI: 10.4012/dmj.23.278

Source DB:  PubMed          Journal:  Dent Mater J        ISSN: 0287-4547            Impact factor:   2.102


  4 in total

1.  405 nm diode laser, halogen lamp and LED device comparison in dental composites cure: an "in vitro" experimental trial.

Authors:  C Fornaini; G Lagori; E Merigo; J-P Rocca; M Chiusano; A Cucinotta
Journal:  Laser Ther       Date:  2015-12-30

2.  Microhardness and polymerization shrinkage of flowable resins that are light cured using a blue laser.

Authors:  Chang-Mo Jeong; Young-Joon Heo; Young-Chan Jeon; Hyung-Il Kim; Yong Hoon Kwon
Journal:  Lasers Med Sci       Date:  2011-07-24       Impact factor: 3.161

3.  Influence of irradiation distance on the mechanical performances of resin composites polymerized with high-irradiance light curing units.

Authors:  Soram Oh; Hyun Ju Kim; Hyun-Jung Kim; Sibel A Antonson; Sun-Young Kim
Journal:  Biomater Res       Date:  2022-05-20

4.  The Influence of Low-Molecular-Weight Monomers (TEGDMA, HDDMA, HEMA) on the Properties of Selected Matrices and Composites Based on Bis-GMA and UDMA.

Authors:  Agata Szczesio-Wlodarczyk; Aleksander Polikowski; Michał Krasowski; Magdalena Fronczek; Jerzy Sokolowski; Kinga Bociong
Journal:  Materials (Basel)       Date:  2022-04-04       Impact factor: 3.623

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.