Literature DB >> 15509308

Routine cerebral angiography after surgery for saccular aneurysms: is it worth it?

Riku P Kivisaari1, Matti Porras, Juha Ohman, Jari Siironen, Keisuke Ishii, Juha Hernesniemi.   

Abstract

OBJECTIVE: The objective of this study was to determine whether an angiographically proven rate of saccular intracranial aneurysm occlusion after surgical clipping suggests that postoperative angiography should continue to be used routinely or should be supplanted by intraoperative angiography. These data also should establish a basis for comparing surgery with new endovascular methods of treatment.
METHODS: During a 3.5-year period, a consecutive series of 622 patients (955 aneurysms, 808 of which were surgically clipped) who underwent postoperative angiography were studied retrospectively. This series comprised 493 ruptured and 315 unruptured aneurysms.
RESULTS: Complete aneurysm closure was achieved in 88% of aneurysms, a neck remnant was discovered in 9%, and a fundus remnant was revealed in 3%. Of 493 ruptured aneurysms, 86% were completely occluded. Of 315 unruptured aneurysms, 91% were completely occluded. The results for clipping of complex aneurysms, i.e., posterior circulation or large to giant aneurysms, were significantly inferior to those for small and anterior circulation aneurysms. In one-third of the large and giant aneurysms, a part of the base was left intentionally because of calcifications or strong wall or to prevent occlusion of any branches. In the series, a significant 5% complication rate of major vessel occlusion was detected.
CONCLUSION: Our retrospective analysis revealed that ruptured, posterior circulation, and large/giant aneurysms are more prone to incomplete clipping. Therefore, these aneurysms require postoperative if not intraoperative evaluation with angiography. Many clippings of anterior circulation aneurysms experience unexpected failures, which suggests that intraoperative angiography could be beneficial. This series, which has no selection bias, can be used as a basis to compare the results of other series reporting surgical or endovascular treatment.

Entities:  

Mesh:

Year:  2004        PMID: 15509308     DOI: 10.1227/01.neu.0000141043.07303.60

Source DB:  PubMed          Journal:  Neurosurgery        ISSN: 0148-396X            Impact factor:   4.654


  18 in total

1.  Intraoperative angiography during cerebral aneurysm surgery.

Authors:  Ravi Kumar; Jonathan A Friedman
Journal:  Neurocrit Care       Date:  2009-05-20       Impact factor: 3.210

2.  Treatment of complex neurovascular lesions: an interdisciplinary angio suite approach.

Authors:  Philipp Dammann; Tobias Breyer; Karsten H Wrede; Klaus-Peter Stein; Isabel Wanke; Astrid E Grams; Elke R Gizewski; Marc Schlamann; Michael Forsting; I Erol Sandalcioglu; Ulrich Sure
Journal:  Ther Adv Neurol Disord       Date:  2014-01       Impact factor: 6.570

3.  Middle Cerebral Artery Aneurysm "Neck Overhang": Decreased Postclipping Residual Using the Intersecting Clipping Technique.

Authors:  Stavros Dimitriadis; Fares Qeadan; Christopher L Taylor; Howard Yonas; Andrew P Carlson
Journal:  Oper Neurosurg (Hagerstown)       Date:  2018-10-01       Impact factor: 2.703

4.  Feasibility of flat panel angiographic CT after intravenous contrast agent application in the postoperative evaluation of patients with clipped aneurysms.

Authors:  M-N Psychogios; D Wachter; A Mohr; P Schramm; A-M Frölich; K Jung; V Rohde; M Knauth
Journal:  AJNR Am J Neuroradiol       Date:  2011-08-18       Impact factor: 3.825

5.  Aneurysmatic subarachnoidal haemorrhage: incidence and location of small ruptured cerebral aneurysms - a retrospective population-based study.

Authors:  Karl Roessler; Manfred Cejna; Iris Zachenhofer
Journal:  Wien Klin Wochenschr       Date:  2011-06-22       Impact factor: 1.704

6.  Angiographic results in intracranial aneurysms treated with inert platinum coils.

Authors:  J R Vanzin; C Mounayer; D G Abud; R D'agostini Annes; J Moret
Journal:  Interv Neuroradiol       Date:  2012-12-03       Impact factor: 1.610

7.  Endoscope-integrated ICG technology: first application during intracranial aneurysm surgery.

Authors:  Michaël Bruneau; Geoffrey Appelboom; Michal Rynkowski; Nathalie Van Cutsem; Benjamin Mine; Olivier De Witte
Journal:  Neurosurg Rev       Date:  2012-08-24       Impact factor: 3.042

8.  Repeated Aneurysm Intervention.

Authors:  Vladimír Beneš; Anna Štekláčová; Ondřej Bradáč
Journal:  Adv Tech Stand Neurosurg       Date:  2022

9.  Intraoperative angiography should be standard in cerebral aneurysm surgery.

Authors:  Jonathan A Friedman; Ravi Kumar
Journal:  BMC Surg       Date:  2009-04-30       Impact factor: 2.102

10.  Adverse intraoperative events during surgical repair of ruptured cerebral aneurysms: a systematic review.

Authors:  William R Muirhead; Patrick J Grover; Ahmed K Toma; Danail Stoyanov; Hani J Marcus; Mary Murphy
Journal:  Neurosurg Rev       Date:  2020-06-16       Impact factor: 3.042

View more